Refrigerator Maintenance
LP gas flame appearance:
While in LP gas operation, examine the appearance of the LP gas flame:
- Set the refrigerator to the maximum cooling level.
- Open the lower intake vent.
The burner box cover can be hot. Wear gloves to
avoid burns.
- Open the burner box door [165] and look at the LP gas flame [75] (See
Art02458 and Art02453).
- The flame should be:
- a darker blue color on the inside of the flame and a lighter blue
color on the outside of the flame.
- a constant shape without flickering.
- Contact your dealer or Thetford authorized service center if the
flame is:
- yellow
- flickering or changing shape.
- Make sure the flame does not touch the inside of the flue tube
[76].
- If the flame touches the inside of the flue tube, contact your
dealer or an authorized Thetford Service Center.
- Close the burner box door.
Remove and clean the burner orifice:
Your dealer or an authorized Thetford Service Center must do this procedure.
To remove and clean the burner orifice:
- Close the valve at the LP gas tank(s).
- Shut down the refrigerator.
The burner box cover can be hot. Wear gloves to avoid burns.
- Open the lower intake vent.
- Remove the drip cup by removing one screw.
- Remove the burner box cover by removing one screw.
To avoid possible LP gas leaks, always use two wrenches to loosen and tighten the LP gas supply line at
the manual shut off valve of the refrigerator.
CAUTION
!
NOTICE
WARNING
!
CAUTION
!
75