adjustment. Should only be performed by qualified 
person with appropriate calibration standards.)

CHANGE FROM FAHRENHEIT TO CELSIUS

 - Press 

and hold ON/OFF button for five seconds at start-up.

GUARANTEE

 - This instrument carries a two-year 

warranty against defects in either components 
or workmanship. During this period, products 
that prove to be defective will, at the discretion of 
ThermoWorks, be either repaired or replaced without 
charge. This warranty does not apply to probes, 
where a six-month period is offered.  The product 
warranty does not cover damage caused by fair wear 
and tear, abnormal storage conditions, incorrect use, 
accidental misuse, abuse, neglect, misapplication 
or modification. Full details of liability are available 
within ThermoWorks' Terms & Conditions of Sale 
at www.thermoworks.com. In line with our policy 
of continuous development, we reserve the right to 
amend our product specification without prior notice.

SPECIFICATION

 - Full specification details of 

all products are available at www.thermoworks.com. 

INSTRUMENT OPERATION

 - Connect probes via 

the socket located at the top of the instrument. 
(The Therma Waterproof uses a miniature type T 
thermocouple connector). Switch the instrument 
on and apply the tip of the probe to the substance 
or medium to be measured. The instrument reading 
may take a few seconds to stabilize, depending on 
the nature of the measurement and sensitivity of the 
probe.

HOLD

 - Press the HOLD button to stop 

measurements and freeze the display temporarily, 
press again to continue measuring.

AUTO-OFF

 - The unit will switch off automatically 

after 10 minutes. To disable auto-off press the HOLD 
button while switching on the instrument (this is 
reset when the instrument is switched off).

OPEN CIRCUIT/FAULTY PROBE

 - If the probe has 

developed an 'Open Circuit' fault the instrument will 
display 'Err'.

SENSORS

 - Therma Waterproof should only be used 

with a type T (copper/constantan) thermocouple 
probe (BS EN 60584-2) fitted with a miniature 
type T thermocouple plug (to BS EN 50212).
This instrument is designed to be compatible with 
ThermoWorks manufactured probes.

BATTERY REPLACEMENT

 - The instrument will 

display a low battery symbol to warn that the 
batteries will need changing soon. The instrument 
continues to measure accurately but after further 
usage the instrument will display 'flat bat' and 
shutdown. Replace the three AAA batteries located 
under the rear case half that is held in place by six  
screws. Check the seal for damage and carefully 
replace the rear case half, re-fit and tighten the 
screws.

MAX/MIN

 - Press the MAX/MIN button to display the 

values. The instrument retains the max/min values 
when switched off. To reset, press the MAX/MIN 
button for three seconds, 'rst' will be displayed. 

BACKLIGHT

 - Press the HOLD button for two 

seconds.  Please Note: the backlight will not 

operate if the low battery symbol is being displayed. 
(Backlight timeout = 20 seconds).

CALIBRATION TRIM 

-

 

Press the MAX/MIN and 

ON/OFF buttons at start-up for five seconds to 
enter ('Offset' is displayed). MAX/MIN then cycles 
(continuous loop) the trim value in 0.1 steps up to 
±2.0ºC (3.6ºF). Press ON/OFF to save the value and 
exit Trim mode. (Instrument should not require trim 

SPECIFICATIONS

–148 to 572°F (–99.9 to 299.9°C)
572 to 2,502°F (300 to 1372°C)
0.1° to 572°C (299.9°C) thereafter 1°
±0.36°F (±0.2°C), ±1 digit
after 10 minutes
3x 1.5V AAA, 10,000 hours
T Thermocouple 
0.6 inches (15 mm) LCD
IP66/67 rated
5.6 H x 2.8 W x 1.26 D inches 
(141 H x 71 W x 32 D mm) 
0.49lb. (220g)
NIST-Traceable certificate included

Range 0.1°:

Range 1°:

Resolution:

Accuracy:

Auto-off:

Battery:

Sensor Type:

Display:

Water Resistance: 

Dimensions: 

Weight:

Calibration: