Data protocol
GBSOTXBA_V(1).DOCX
Page - 22
5.5.9 Reset
Command byte
“R”
Description
All modules are reset. The LEDs are switched off and the button memories are cleared.
The buffer memory is also cleared.
Parameter
-
Answer
Result byte: see chapter 5.3
Broadcast possible
The command applies to all modules; shelf number and compartment number are
ignored.
Note:
In operation mode “Counting Frame” the RESET command will
not
clear the counter values. Please use
the „Clear Value“ command.
5.5.10 Signal transducer ON and OFF
Command byte
“S”
Description
The signal transducer connected to the control unit is switched on or off.
Parameter
“0”: OFF
“1”: ON
Answer
Result byte: see chapter 5.3
Broadcast possible
Not applicable. Shelf number and compartment number are ignored
5.5.11 Sensor delay time
Command byte
„T“
Description
Set the sensor delay time. This value determines how long a button (or sensor) needs to
be activated before the button memory is set to “1”.
Parameter
„0“: 0 ms
„1“: 1 ms
„2“: 2 ms (default for Counting Frame)
„3“: 5 ms
„4”: 10 ms
„5“: 20 ms (default for IN-SorTexx and OUT-SorTexx)
„6“: 50 ms
„7“: 100 ms
„8“: 200 ms
„9“: 500 ms
Answer
Result byte: see chapter 5.3
Broadcast possible
yes
5.5.12 Counting frame: Poll counter value
Command byte
„U“
Description
Returns the current counter value.
If “send value automatically“ is activated (menu 2), the control unit will automatically send
any value that has changed.
Example: „<008502U00>“ means that counter 2 has a value of 85
Parameter
-
Answer
Result byte: see chapter 5.3
Bytes 1…4 contain the counter value („0000“…“9999“)
Broadcast possible
Yes. The counter values of all connected counting frames will be sent consecutively.