USER INSTRUCTIONS

 

 

 

4

3

2

GREEN AREA

1.2 bar

0.5 bar

1.5 bar

3 bar

M

R

    Topping-up the system with water 

The  water  pressure  in  the  central  heating  circuit  must  be 
checked during the entire period of operation of the boiler. 
In  this  respect,  the  reading  on  the pressure gauge M (fig. 
2), located on the lower part of the boiler, must not be less 
than 1 bar. 

If there is insufficient water in the boiler, the code H2O will 
flash on the display  (see fig 2).  

To  bring  the  system  back  up  to  pressure,  open  the 
external filling tap (fig. 2) and use the pressure gauge M 
(fig.  2)  to  check  that  the  systems  pressure  reaches  the 
middle of the green area (equal to 1,2 bar, see fig. 3) and 
that the code H2O lights up. 

When the operation is complete, close the fill tap.  

 

 
Diagnostics – Error codes: 

This paragraph contains a list of error codes that the boiler 
may  generate  on  the  display  8  (see  “Control  panel”) 
together  with  the  relative  indications  and  the  operations 
that the user can carry out to reset the boiler. 

 

If  the  problem  re-occurs  after  the  following 
actions  have  been  taken,  call  an  authorised 
Service Centre. 

 

 

_

E01

E01

E01

E01

  

Ionisation block

 

Code E01 lit continuously on the display.   

  Check that the gas valve on the boiler and gas meter are open and that there is gas in the mains supply (or in 

the tank).  

  Switch off then switch on the appliance using switch 1 (see “Control panel”) on the control panel. 

  When  the error code on the display disappears, the boiler will restart. 

If the problem persists, Call the Service Centre. 

 

_

E02

E02

E02

E02

_  Safety Thermostat tripped

 

Code E02 lit continuously on the display.  Call the Service Centre. 

 

_

E03

E03

E03

E03

_  Flue Gas Thermostat tripped

 

Code E03 lit continuously on the display.  Call the Service Centre. 

 

_

h2o

h2o

h2o

h2o

_  Water Pressure Switch tripped

 

Code H2O lit continuously on the display.   

  Check  the  water  pressure  in  the  central  heating  circuit.  The  reading  on  the  pressure  gauge  M  (see  fig.  3), 

located on the lower part of the boiler, must not be less than 1 bar . 

  If the pressure is less than 1 bar, top-up the system as described in paragraph “Filling the system”. 

  The boiler will restart automatically. 

If the problem persists, Call the Service Centre. 

Содержание EKR 18

Страница 1: ...CE 0694 User Manual for model Premix condensing boiler EKR 18 ENGLISH...

Страница 2: ......

Страница 3: ...ion in accordance with current standards and where the minimum external temperature does not fall below 10 C The manufacturer will not be held responsible for installation in locations where the tempe...

Страница 4: ...S CALL FOR PROFESSIONALLY QUALIFIED PERSONNEL Boiler controls Control panel LEGEND 1 ON OFF SWITCH 2 HEATING TEMPERATURE CONTROL KNOB 3 D H W TEMPERATURE CONTROL KNOB 4 D H W TEMPERATURE DISPLAY BUTTO...

Страница 5: ...ic ignition system will light the burner every time there is a demand for room heating In this case the symbol on the control panel will flash SUMMER WINTER mode To switch boiler operation to SUMMER W...

Страница 6: ...If the problem re occurs after the following actions have been taken call an authorised Service Centre _E01 E01 E01 E01_ Ionisation block Code E01 lit continuously on the display Check that the gas v...

Страница 7: ...on the display Call the Service Centre _E22 E22 E22 E22_ Parameter programming request Code E22 lit continuously on the display Call the Service Centre N B If the boiler is to be left unused for a lon...

Страница 8: ...THER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION ERRORS E OEALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE REPRODUCED MEMORISE...

Отзывы: