ThermoSphere MH-0600 Скачать руководство пользователя страница 7

HEA

TING 

| W
ALL | MIRROR

7

P

I

R

ThermoSphere mirror heater requires a mains supply, marshalling 
box and a switch or PIR sensor. Measure and mark out all the 
necessary items before you install the electric mirror heater. 
If necessary chase into the wall to accommodate fixtures and 
wires.

If you are installing your mirror into a rebate within the tiles, 
ensure you leave a 5mm gap around the perimeter of the mirror. 
Any contact with hard materials could result in a breakage.

Mirror heaters can be controlled with the ThermoSphere dual 
control. Connect the mirror cold tail to the secondary relay, as 
shown above.

ThermoSphere electric mirror heaters can be wired into an existing 
lighting circuit using a PIR.

Remember to position the mirror heater connection box and 
power cable in the closest available position to your electrical 
connection to the PIR.

Wiring to a light circuit

Wiring to a PIR sensor

P

I

R

Thermomirror

Thermomirror

Light

Light 
Switch

PIR

Ensure mains supply 
is RCD protected

Ensure mains 
supply is RCD 
protected

!

!

ThermoSphere mirror heater

5mm Expansion Gap

Tiles

!

Отзывы: