ThermoSphere DC-B Скачать руководство пользователя страница 26

26

MENU

DESCRIPTION

RANGE

DEFAULT

01

Maximum Temp Limit

5°C ~ 40°C

27°C

02

Minimum Temp Limit

5°C ~ 15°C

5°C

03

Maximum Set Temperature

5°C ~ 40°C

35°C

04

Floor Temperature Calibration

-10°C ~ 10°C

0°C

05

Ambient Temp. Calibration

-10°C ~ 10°C

0°C

06

Sensor Calibration

See page 30

10k

Ω

07

Rail Control 

ON, OFF 

OFF

08

Language 

English, French, German 

English

Advanced settings

Содержание DC-B

Страница 1: ...DC W DC B INSTRUCTION GUIDE CONTROL TOUCH DUAL Excellence in heating solutions 23 Target Temp 25 06 00 Friday...

Страница 2: ...lling Your thermostat Wiring diagram User interface Settings Set the time and date Heating schedule Appliance controls Heating modes Energy saving features Advanced settings Compatible sensor probes T...

Страница 3: ...l can replace your existing underfloor heating thermostat as it s compatible with many of the most popular thermostat brands floor sensor probes including those rated at 6 8k 25 C 10k 25 C 12k 25 C 15...

Страница 4: ...u ve got everything ThermoSphere Dual Control Floor sensor probe 2m Floor sensor conduit 3m Fixing screws Manual and warranty information You will also need Electrical screwdrivers Deep electrical bac...

Страница 5: ...nstalled on an RCD protected circuit Away from drafts or heat influences Installed so that the floor sensor probe can be laid in a clear temperature representative area of the floor Set to floor sensi...

Страница 6: ...installing your thermostat as part of a high voltage mains electrical circuit To ensure your safety and to protect the thermostat switch off the mains power before you start the installation CAUTION...

Страница 7: ...protected electric underfloor heating system has been installed and a back box is already in place The underfloor heating cold tail should be pulled up through the back box and the sensor probe instal...

Страница 8: ...ed up to 50m away from the underfloor heating system it is controlling provided that the floor sensor is used to control the temperature Underfloor heating cold tails and floor sensor probes can be ex...

Страница 9: ...Appliance Live Common Earth Ground Sensor connections 4 Wiring diagram Connect to the underfloor heating UFH cold tail additional appliance power supply and floor temperature sensor The floor tempera...

Страница 10: ...face plate away from the back plate Carefully disconnect the ribbon cable and align your thermostat with the mounting positions on the pre installed back box Fix in place with the screws provided Now...

Страница 11: ...1 Time date 2 Heating mode 3 Appliance mode 4 Power 5 UFH on icon 6 Appliance on icon 7 Measured temperature 8 Target temperature 9 Sensor mode icon 10 Menu 11 Down arrow 12 Up arrow 23 Target Temp 2...

Страница 12: ...the automatic schedule for your underfloor heating and an additional appliance Display settings Change the backlight timer as well as the minimum brightness Select the home screen wallpaper from 8 di...

Страница 13: ...h floor limit sensor modes Ambient with floor limit will react to the ambient temperature primarily but will switch off if the floor temperature gets too high Advanced settings Floor and ambient temp...

Страница 14: ...tch our thermostat on you will need to set the current time and date You can do this by pressing Menu and then Date Time Use the arrows to select the right date and time and then press confirm to save...

Страница 15: ...ience by automatically changing the temperature of your underfloor heating system Each day of the week can be programmed independently There are 6 heating events for every day Most people treat them a...

Страница 16: ...ready selected Set the time you want your heating to come on in the morning and the temperature you want your floor to heat up to using the up and down arrows 1 2 3 4 5 6 06 30 21 0 06 30 21 0 08 00 1...

Страница 17: ...that means your heating is effectively off We recommend around 6 C less than the temperature you set when the floor is warm Press confirm to save your settings Repeat steps 8 9 for heating events 3 4...

Страница 18: ...ff times and temperatures for Tuesday Press confirm to save your settings Press back select the day and repeat the process for the remaining days of the week Press confirm to save your settings and pr...

Страница 19: ...g for a period in the afternoon and then again in the evening You can adjust the time and temperature of any of these heating events to suit your lifestyle Mon Fri Sunday 06 00 25 0 08 00 18 0 12 00 1...

Страница 20: ...hedule press Copy press OK and then press confirm to save your settings This will copy all of the on off times from your UFH schedule to the appliance schedule Now select a day use the arrows to selec...

Страница 21: ...l from the home screen On The appliance will stay on until you turn it off again Schedule The appliance will switch on and off according to the appliance heating schedule Appliance boost Switches the...

Страница 22: ...floor Comfort Maintains a higher temperature usually between 22 27 C that will keep you warm on a cold day Both of these modes can be set to stay on forever until you change it for a 1 2 or 4 hour bo...

Страница 23: ...rature Your thermostat will maintain the boost temperature until the next scheduled heating event Manual You can manually select any temperature and must make all temperature changes yourself Holiday...

Страница 24: ...on early Your thermostat starts learning from the first time you enable the heating schedule It turns on an hour early to start with and gradually optimises the heat up time over 7 days Open Window D...

Страница 25: ...d settings Adjusting the advanced settings To access the settings press Menu then the green Settings icon In this menu you can set up and control all of the more advanced settings for your thermostat...

Страница 26: ...Temp Limit 5 C 15 C 5 C 03 Maximum Set Temperature 5 C 40 C 35 C 04 Floor Temperature Calibration 10 C 10 C 0 C 05 Ambient Temp Calibration 10 C 10 C 0 C 06 Sensor Calibration See page 30 10k 07 Rail...

Страница 27: ...ry reset Re yes 10 Adaptive Start 1 On 0 Off Off 11 Open Window Detection 1 On 0 Off Off 12 OWD Off Time 2 30 minutes 15 mins 13 OWD Temperature Drop Limit 2 3 or 4 C 2 C 14 OWD Heating on again after...

Страница 28: ...ith some of the most popular sensor probes available Tep 6 8k 25 C THE 10k 25 C Default ENS 10k 25 C OJ 12k 25 C Dev 15k 25 C Ebe 33k 25 C Replacing an existing thermostat Contact the manufacturer s t...

Страница 29: ...UFH relay 16A 3600W Appliance relay 5A 1125W Temperature range 5 35 C Ambient 0 50 C Compatible sensors 6 8k 10k 12k 15k 33k Accuracy 0 5 C Warranty 3 years IP rating IP30 Width 129mm Height 88mm Dep...

Страница 30: ...Excellence in heating solutions ThermoSphere Pattenden Lane Marden TN12 9QJ 0800 019 5899 hello thermosphere com thermosphere com DUAL IG 01...

Отзывы: