7.3.3 CONTROLS PRIOR TO INSTALLING THE APPLIANCE
The user must possess a certificate of conformance for the flue outlet (Ministerial Decree 22 January 2008, no. 37).
The flue outlet must be built in compliance with UNI 10683.
The smoke exhaust illustrated in the following figure is the best solution required to ensure that the flue gases are discharged. If you
prefer to exhaust the smoke from the roof insert a union tee with inspection cap, connecting brackets suitable for the height of the
flue outlet, flashing that crosses the roof and chimney cap to protect against bad weather conditions.
LEGENDA
KEY
COMIGNOLO E CANNA FUMARIA
SECONDO NORMA UNI 10683
CHIMNEY CAP AND FLUE OUTLET
ACCORDING TO UNI 10683
STANDARD
Tutte le tubazioni devono essere
termicamente isolate
All the pipes must be thermally
insulated
ISPEZIONE
INSPECTION
ALTEZZA SUPERIORE A 4 metri
HEIGHT MORE THAN 4 m.
Pendenza non inferiore al 5%
Minimum slope 5%
2 metri MAX
2 metres MAX
2-3 metri MAX
2-3 metres MAX.