C o m m u n i c a t i o n s
10
Configuration level
Display
Address
Range
Initiation
Dec. point
Note
In1
200 r/w
Thermocouple input:
0 …
no
1 …
J
2 …
K
3 …
t
4 …
n
5 …
E
6 …
r
7 …
S
8 …
b
9 …
C
10 …
d
RTD input:
0 …
no
1 …
rtd
Process input:
0 …
no
1 …
0-20
2 …
4-20
3 …
0-5
4 …
1-5
5 …
0-10
0
Setting of the input sensor
dEC1
201 r/w
tc and rtd input:
0 …
0
1 …
0.0
Process input
0 …
0
1 …
0.0
2 …
0.00
rL1
202 r/w
-4990 to
rh1
-4990
dEC1
Low range of process input
rh1
203 r/w
RL1
to 24990
24990
dEC1
High range of process input
Ftr1
204 r/w
0 to 600
0 …
oFF
10
1
Input filter
ot1
210 r/w
0 …
ht
1 …
CL
2 …
ht2
3 …
CL2
0 for SSD
and proc
2 pro relay
Setting of the control output
PLd1
211 r/w
0 to 100
100
0
Output power limit below
SPL1
SPL1
212 r/w
-4990 to 24990
250
dEC1
SP value for power limit function
PLu1
213 r/w
0 to 100
100
0
Output power limit above
SPL1