Holiday (Manual)

Keep a constant temperature up to the day of return from the vacation,
then switch to the MANUAL mode (the last selected program before
departure). It is not possible to set the Summer mode (setting values,
constant No. 4!

Press the “       “ button to select 

Holiday (Manual)

, confirm

by “       “ button. Use the similar setting as in Auto mode. After
expiration of the set period of vacation, the thermostat returns to
the manual mode. 

DHW is always disconnected

.

Main menu

Setting

Pr

ogr

amming and 

setting par

amet

e

rs

Setting clock

setting the actual time and date.

Setting program 

(factory setting prog:1)

Setting programs for CH and DHW.
The thermostat can set 9 weekly programs for heaiting and 6
thermal changes per day. Programs No. 8 and 9 are designed
for automatic changes in even and odd weeks.
During selection of permanent CH temperature (4. Regulation
mode “3“ Permanent CH temperature) output temperature from
the boiler or the cascade is always set.

Press the “       “ button, by turning ”      “ select the mode 

Setting clock

, confirm by “      “ button. Turn the “       “ to

change the values and confirm the selected values by pressing 
”        “ button

(Symbols above the set parameter always

flash. Turn “

“ to browse between data, press the but

ton  “       “ to return to menu).

Press the “      “, button and turn the”     “ to select

Setting program

mode, confirm by “      “. Turn the

“      “ to select the program and confirm by ”      “ 

button. Select the requested day in the same manner.
First, select the time of the change and then the 
requested room temperature. Proceed in such manner
up to the last terminal. If you know that the following day
will be the same, press the button  “

COPY

“. The 

program is copied.  The text “

COPY

“ flashes on the

right upper side

(the set data always flashes, turn the “     “ button
to browse between the data, press the”      “ button to
go back one step back in programming). 

When programming DHW, proceed in a similar manner, set
the time sections for the heating of DHW.

Program CH

Program DHW*

*

Control DHW: When connecting an external sensor (see diagram on page 2), No.17 constant setting to "for DHW" and 

location of the sensor in the tank, there is regulation DHW according to set program (with a hysteresis of ± 5 ° C according
to location of the sensor in the tank).  

Parameters

Setting the regulation parameters and the heating system.

2. Min. program. temper. 

(factory setting 5°C)

Temperature limit - it is not possible to set the room 
temperature below this limit when programming. 
Select within the range from 

2 °C to 10°C (by 0.5°C).

3. Max. program. temper. 

(factory setting 39°C)

Temperature limit - it is not possible to set the room 
temperature above this limit when programming. 
Select within the range from 

15 °C to 39°C (by 0.5°C).

4. Mode 

(factory setting 0)

Status of the mode in which the thermostat will work. 

0 - Required temper.regulation, 

the thermo-

stat heats for requested temp. at the stated time.

1 - Premature switching (PS), 

during two day of opera

tion, the thermostat ascertains thermal constants 
of the reference room and then switches the 
heating with requested advance (for restriction of 
advance, see constant No. 5 below).

2 - Summer mode,

the thermostat does not heat, 

only controls the heating of DHW.

3 - Permanent temp. CH,

the thermostat keeps 

temperature of heating water within the limits of the set 
time and the constant 6 (MIN. TEMP. CH) and 7 (MAX. 
TEMP. CH).

5. Start-up sooner max. 

(factory setting 2 hours)

When 

PS is activated

! The thermostat may 

activate the heating at the set number of hours in 
advance.
Optional range  

0.5  to 6.0 hours (by 0.5 hours).

Press the “       “ button, by turning the button ”      “ select the

Parameters

mode. Confirm by pressing the “      “. 

Turn the “       “ button to browse through the constants.

Turn the “       “ button to set the minimum adjustable 
temperature and confirm with ”       “ button. 
Constant No. 3 automatically appears.

Turn the “       “ button to set maximum adjustable 
temperature and confirm with ”       “ button.
Constant No. 4 automatically appears.

Turn the “       “ set the maximum time in hours to show
the time in advance it is possible to activate the heating
so that the temperature reaches the requested value by
the stated time. Confirm by ”     “ button. 
Constant No. 6 automatically appears.

Constants

1. Cesky 

(factory setting Cesky)

Selection of language.

Turn the “       “ to select and press the ”       “ button. 
Constant No. 2 automatically appears.

3

Select program
Program: > 1

<

Monday

1.

6:00

22.0°C

2.

9:00

19.0°C

3.

14:00

22.0°C

4.

16:30

24.0°C

5.

21:30

19.0°C

6.

21:30

19.0°C

Select program
Program: > DHW <

Monday

1.

0

-

24

45.0°C

2.

24

-

24

45.0°C

3.

24

-

24

45.0°C

The last program is reserved for the management of DHW. For
boilers with flow heating, it is possible to set 3 time sections with
various temperatures (from 35 °C  to 60 °C ). For boilers with
tanks, the temperature of DHW is set on the boiler and on
PT59X ; setting the temperature only enables activation of the
boiler for heating the boiler.

Turn the “       “ button to select the required regulation
mode and confirm with ”       “ button. 

In the case of selection of the 

mode “ 0 ”

the constant No. 5

is skipped and the constant No. 6 is immediately appeared.

In the case of selection of 

mode “1“ 

, constant No.5 auto-

matically appears

(in the list of information , the text 

“required temperature in premature switching“ appears).

In the case of selection of 

mode “2”

, constant No. 5 is

skipped and constant No. 6 immediately appears

(on the

introductory screen the text “Summer mode” appears).

I

n the case of selection of the 

mode “3“

the constant No. 5

is skipped and the constant No.6 is immediately appeared.
On the introductory screen the text “required IN“ and at this
mode the stated actual value of required-permanent 
temperature of heating watter is appeared.

Содержание PT59X

Страница 1: ...nual mode Turn the button to change the actual value of the requested temperature in automatic mode up to the further time section or select another programme Turn the button to switch between the temperature and the programme LCD COPY 1 2 3 4 5 6 7 Control elements Button function PRESSING Button function TURNING 1 2 3 4 5 6 7 01 01 13 21 45 Thuesday AUTO prog 1 per 1 01 01 13 21 45 Thuesday AUTO...

Страница 2: ...equested temp is performed by pressing the or button cannot be set when in the OFF mode or the Summer mode Press the button by turning select the Manual mode confirm by button The quick change of the requested temperature is performed similarly as when in automatic mode Press the button by turning select the Auto off mode confirm by button Mode OFF in automatic is cancelled by selection of another...

Страница 3: ... of the mode in which the thermostat will work 0 Required temper regulation the thermo stat heats for requested temp at the stated time 1 Premature switching PS during two day of opera tion the thermostat ascertains thermal constants of the reference room and then switches the heating with requested advance for restriction of advance see constant No 5 below 2 Summer mode the thermostat does not he...

Страница 4: ... and press the button to confirmation In the case of selection of equithermal regulation follow the instructions under the graph with the heating curves If selecting a requested room temperature of other than 20 C the thermostat calculates the automatic shift of the curve according to the following equation where the coefficient is 1 shift requested temper 20 coefficient Note the most frequently u...

Страница 5: ... regulation and follow instructions shown at the graph Turn the button to consequently set day month and year for the revision and confirm each setting by the To speed up the setting press the button COPY which displays the actual date The revision is cancelled by the change of the date of revision After setting constant No 17 automati cally appears or 15 in service mode At the stated date the tex...

Страница 6: ...entered ust be acknowledged by the button After setting the last number constant No 20 automatically appears 1st numeral The telephone number is entered in the international format without or 00 at the beginning In the case that the telephone number has 10 or 11 digits an empty place is set on the last position after entering the last number Press the button to switch to the next constant In the c...

Страница 7: ... where x are values within the range 0 to 5 0 cannot be determined or no signal is detected 1 the worst signal level 5 the best signal level FORMAT FOR BACK MESSAGES FROM PТ59X Off Deactivated heating system Off AUTO The thermostat is in automatic mode MANU The thermostat is in manual mode Noakcept Signals an error incorrectly entered SMS etc xx x temperature in C Note In the case of exceeding the...

Страница 8: ...se of not keeping to the intended manner of use and maintenance of the product 4 intervention by unauthorized persons into the product 5 unprofessional repair of the product The OpenTherm protocol enables to send important error messages from the boiler into the thermostat The thermostat displays these messages on the last line of the display E xxx where xxx can be from 001 to 255 This type of err...

Отзывы: