background image

1725        II 2 GD  Ex eb mb [ib]ib IIC T4, Ex tb IIIC T135°C
               SIRA 12ATEX5239X

IP66

-60

°

C  

  Ta 

  + 55

°

C

IECEx SIR 12.0103X Ex eb mb [ib]ib IIC T4, Ex tb IIIC T135°C

PN 27673

D

o n

ot o

pen

 while

 ener

gized. See i

nstall

atio

n in

str

uc

tio

ns

Te

rm

inator EC

M

 

Fo

r u

se

 as

 an

 adj

ustable

 electronic c

ontro

l m

od

ule

The Heat Tracing Specialists

®

Terminator

 

TM

 ECM-P-XP

Electronic Control Module

INSTALLATION PROCEDURES

For Connection (1-2 Heating Cables) Applications

Содержание Terminator ECM-P-XP

Страница 1: ...ib IIC T4 Ex tb IIIC T135 C PN 27673 D o not open while energized See installation instructio n s T e rminator EC M F o r u s e as an adjustable electronic control m o d u l e TheHeatTracingSpecialists TerminatorTM ECM P XP Electronic Control Module INSTALLATION PROCEDURES For Connection 1 2 Heating Cables Applications ...

Страница 2: ...e energize all power sources before opening enclosure Avoid electrostatic charge Clean only with a damp cloth Keep ends of heating cable and kit components dry before and during installation Minimum bending radius of heating cable is 32 mm except HPT is 57 mm and FP is 19 mm Individuals installing these products are responsible for complying with all applicable safety and health guidelines Proper ...

Страница 3: ...with grommet provided in PETK 3 ECM 4 Slide expediter toward pipe and route cable through support base entry 8 Terminate cable with appropriate PETK termination kit Refer to PETK installation instructions 9 Push excess cable back through expediter Tighten cap securely Tape cable expansion loop to pipe 6 Mount expediter to pipe using pipe band Do not band over cable 7 Cut off end of cable Terminato...

Страница 4: ...nstall junction box lid and twist hand tight Insert screwdriver into ratchet slots located on side of junction box base 17 Lid latch mechanism fully engaged To remove lid repeat step 16 but in the opposite direction The Heat Tracing Specialists 15 Use the rotary switches for settling Control and Limit Temperature Celsius or Fahrenheit and Auto or Manual reset Control switches on Type C Limiter swi...

Страница 5: ...ble Layout Tips Insert two cables into expediter Note For HPT and FP cable exchange grommet in Terminator with grommet provided in PETK 3 ECM Wiring Details Connection 1 or 2 Heating Cables L L N N C NO NC Comm Port Alarm Relay Main supply Heater output B B A A B B RTD Limiter Sensor RTD Controller Sensor GND 1 2 TerminatorTM ECM P XP INSTALLATIONPROCEDURES ...

Страница 6: ...on jusqu au point de blocage 17 La sécurité de blocage est complètement engagée Pour ouvrir le boîtier répéter l étape 16 mais dans l autre sens de rotation Deutsch Terminator ECM P XP Elektronisches Regelmodul INSTALLATIONSANWEISUNG Für Temperatursteuerung anschluss 1 bis 2 Heizkabel Warnhinweise Wegen der Risiken eines Stromschlags eines Funkendurchschlags oder eines Feuers die durch Produktbesc...

Страница 7: ...s calefactores Advertencias Debido al riesgo de descargas eléctricas arcos eléctricos y fuego causados por daños en el producto o incuorrecta manipulación instalación o mantenimiento se requiere proteger el circuito mediante un diferencial La instalación debe cumplir con los requisitos de Thermon incluyendo el estándar PN 50207U para sistemas Ex y debe instalarse acorde a las regulaciones según la...

Страница 8: ...erdere kabels 2 Voer de RTD voeler s in het doorvoerrubber Trek niet aan het uiteinde van de RTD voeler als deze door het doorvoerrubber in de opvoersok doorgevoerd wordt Trek aan het draadgedeelte de voeler door 3 Steek de kabel door het rubber en de opvoersok heen Zorg ervoor dat de knooppunt in de verwarmingskabel betreffende HPT and FP zich buiten de voet bevinden Let op Voor HPT en FP dient h...

Отзывы: