background image

INSTALLATION INSTRUCTIONS 

BALANCING VALVES WITH PROPRESS FITTINGS

CSUA-PP & CSUAS-PP

353 Ivyland Road • Warminster, PA 18974-2205 • Phone: 1-877-379-8258 • CircuitSolver.com

Buy American to Build America®

Embrace the Technology

®

MULTI-BRANCH PARALLEL

PIPING CIRCUIT:

1)  Install assembly with proper flow direction as marked on valve body. This is critical with CircuitSolver® Union  

Assemblies that have an integrated check valve.

2a) Use suitable pipe thread sealant rated for domestic water applications on all male pipe threads; if using PTFE 

sealant tape, make sure not to apply tape to the first thread to avoid cutting the PTFE tape and causing potential 

obstructions to flow.

2b)

  How to apply PTFE Tape:

   

1. Clean the male and female threads of any oil or dirt.

   

2. Apply tape to the male threaded end in a clockwise direction starting one thread back from the end. 

 

 

    Hold on to one end of the tape, and wrap the threads three to six times, keeping it tight.

   

3. Once the threads are completely wrapped, grab the tape with your thumb and index finger and snap it off.

 

NOTE:

 Upon tightening the assembly, verify that the shutoff valves are oriented so that their handles are accessible 

and can be operated fully without obstruction. If a reorientation after final installation is needed, loosen the  

CircuitSolver® 

Union Nut to rotate the section so as to not disturb the tightened components and possibly cause a 

leaky connection.

3)  When using Viega ProPress® adapters (CircuitSolver Models 

 

 ending in -PP), please consult the Viega ProPress Installation Manual 

 

 for proper installation, tools, etc.

     Visit 

https://www.viega.us/en/products/ProPress/Downloads.html

4)  

CircuitSolver®

 Union Assemblies are designed to be installed 

 

 at the end of each domestic hot water supply just prior to the 

 

 return line. See diagram to the right.

5)  For water systems with particulate/dirt problems,  

 

 

 

 

 

 

 

 

 consider using a strainer if one is not already used upstream.

     *Strainer must be maintained in order to avoid flow obstruction.
6)  A convenient drain port allows for the system branch to be  

 

 

 

 

 

 

 

 flushed without disconnecting plumbing lines.

Scan to watch a quick tutorial video

on proper reorientation instructions.