Thermoheat LPFA125/L Скачать руководство пользователя страница 14

FA40   THROUGH   FA150   STEEL   BASE   UNITS

QTY

FA60   SERIES

LPFA125   SERIES

1

INNER   SHELL      ASS'   Y

1

2304818

2304929

2

NOZZLE

1

2325121

5030077*

3

FLAME   HOLDER   CAP

1

2325120

2325122

4

THERMAL   SWITCH   BRKT.

1

2304826

2315515

5

THERMAL   SWITCH   

1

2201599

2201373

6

NOZZLE   NUT

1

2304578

2304945

7

SPARK   PLUG   ASSY

1

2206033

2206034

8

THERMOCOUPLE   ASSY   (1130/1474-­‐425L)

1

2304885

2304885

9

GAS   TUBING   ASS'   Y

1

2304830

2325138

10

OUTER   SHELL   -­‐   ORANGE

1

2305403

2325360

11

CORD   WRAP

2

N/A

2101423

12

HANDLE   ASSY   -­‐   BLACK

1

2101447

2101447

12.1

SCREW   -­‐   HANDLE   FRONT

1

2001355

2001355

12.2

SCREW   -­‐   HANDLE   FRONT

1

2001077

2001077

12.3

NUT   -­‐   HANDLE   REAR

1

2000384

2000384

13

MOTOR   SUPPORT

1

2304823

2304823

13.1

BOLT-­‐MOTOR   MOUNTING

2

2001332

2001332

13.2

SLEEVE

1

2304949

2304949

14

MOTOR   ASS'   Y

1

2304547

2304548

14.1

MOTOR   -­‐   FAN

1

2304821

2304936

15

GUARD   FAN   -­‐   BLACK

1

2304828

2304939

16

MOTOR   BRKT

1

2304937

2304938

17

VALVE   -­‐   GAS

1

5051233

5051235

18

PRESSURE   SWITCH

1

N/A

2305976

19

VALVE   BRKT

1

2304624

2304624

20

BASE   ASSY   -­‐   BLACK

1

2304923

2304924

21

POWER   CORD   ASS'   Y

1

2101670

2101673

22

GAS   CONNECTOR   INLET

1

2304831

2304831

23

CAPACITOR   

1

2201372

2301390

24

BASE   LOWER   -­‐BLACK

1

2304925

2304926

25

KNOB   GAS   VALVE   -­‐   BLACK

1

2101451

2101451

26

HEIGHT   CONTROLLER   -­‐   BLACK

1

2304927

2304928

27

HEIGHT   CONTROL   SCREW   -­‐   BLACK

1

2304510

2304510

28

LEAD   WIRE   ASSY

1

2201371

2201371

29

SPARK   MODULE

1

2201391

2201391

30

PCB   ASSEMBLY

1

2201369

2201369

31

REG   &   HOSE   ASSY   -­‐   10FT   (3M)

1

5002614

5055549

REG   &   HOSE   ASSY   -­‐   10FT   (3M)   w/HANDWHEEL

1

5055533

5055551

REG   &   HOSE   ASSY   -­‐15FT   (4.6M)

1

5055298

5055550

REG   &   HOSE   ASSY   -­‐15FT   (4.6M)   w/HAND   WHEEL

1

5055415

5055552

USE   THIS   CHART   WITH   THE   EXPLODED   VIEW   OF   THE   FA125A   ON   PAGE   20   0F   THE   MANUAL   CHRISTY   SENT   ME   YESTERDAY.

ITEM               

No.   

DESCRIPTION

PART   NUMBER

*Not   shown   in   exploded   view.

13

 

         

14

rePlaceMent Parts list

PROPANE CONSTRUCTION HEATER

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

Содержание LPFA125/L

Страница 1: ...ss or damage from the hazards of fire explosion burn asphyxiation carbon monoxide poisoning and or electrical shock Only persons who can understand and follow the instructions should use or service th...

Страница 2: ......

Страница 3: ...ON 65 Fuels used in gas or oil fired appliances and the products of combustion of such fuels contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm...

Страница 4: ...eath 3 Other standards govern the use of fuel gases and heat producing products in specific applications Your local authority can advise you about these IMPORTANT Read this user s manual carefully and...

Страница 5: ...CSA B149 1 The minimum and maximum inlet pressures to the regulator from the gas tank are 5 psi and bottle pressure respectively Use only the regulator hose assembly provided with the heater Inspect...

Страница 6: ...quired 4 Screws ST3 5x10 and 2 Cord Wrap Attachments Place the cord wrap attachment as shown then use Phillips screwdriver to tighten the screws and secure the cord wrap attachments 2 Regulator and Ho...

Страница 7: ...Outlets and Inlet Connections A safety relief valve having direct communications with the vapor space of the tank An arrangement of vapor withdrawal The propane LP gas pressure regulator and hose asse...

Страница 8: ...re that the cylinder is fully upright for vapor withdrawl see size capacity page 6 2 Connect hose to heater inlet Tighten firmly using a wrench You must use the regulator supplied with heater 3 Connec...

Страница 9: ...ssembly should be visually inspected prior to each use of the heater If it is evident that there is excessive abrasion or wear or the hose is cut it must be replaced prior to the heater being put into...

Страница 10: ...ny Mainte nance functions Unplug the unit from the 120V receptacle 2 Keep unit clean and keep the inside of the torpedo housing debris free 3 Have unit checked by a qualified technician at least once...

Страница 11: ...urrent to electric outlet If voltage is correct electrical connec7on is made check power cord and extension cord for 2 Fan blade contacts inside of heater housing 2 Be sure that housing is not damaged...

Страница 12: ...s only 100K 125K 150KS lo modelos 100K 125K 150K Les mod les Seulement PROPANE CONSTRUCTION HEATER LPFA125 Series Models Only LPFA 125 Series S lo Modelos LPFA125 S ries Les mod les Seulement NEVER LE...

Страница 13: ...12 PROPANE CONSTRUCTION HEATER REPLACEMENT PARTS LIST MODELS RMC FA60 Series LPFA125 Series NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING...

Страница 14: ...304828 2304939 16 MOTOR BRKT 1 2304937 2304938 17 VALVE GAS 1 5051233 5051235 18 PRESSURE SWITCH 1 N A 2305976 19 VALVE BRKT 1 2304624 2304624 20 BASE ASSY BLACK 1 2304923 2304924 21 POWER CORD ASS Y...

Страница 15: ...long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or excl...

Страница 16: ...SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 8280...

Отзывы: