Selection guide
General recommendations for
HEATSTRIP
®
Elegance with Remote and App Control:
•
Ideal mounting height: 2.3m to 2.5m. Maximum is 2.7m in a fully protected/enclosed outdoor environment.
•
Ideal mounting location: ceiling mounted, directly above area to be heated (eg. above a table)
•
Minimum recommended heating capacity for various installations are: 400W/m
2
for indoor spot heating; 500W/m
2
for protected outdoor areas, and 600W/m
2
for exposed outdoor areas. To ensure the HEATSTRIP
®
Elegance pro-
vides satisfactory performance, Thermofilm strongly recommends using conservative coverage areas when speci-
fying how many heaters are required for each installation.
The table below outlines the
maximum
coverage of each
HEATSTRIP
®
Elegance with Remote and App control
model
based on 2 different scenarios with direct overhead mounting at minimum installation height. For example, for an outdoor
area that is protected from prevailing winds by walls, café blinds etc, Model THE2400R will cover a
maximum
of 4.8m
2
and
Model THE3200R will cover a
maximum
of 6.4m
2
.
For angled wall mounting applications, the coverage is reduced by up to 40%.
MODEL
INDOOR PROTECTED (m
2
) OUTDOOR ENCLOSED (m
2
)
OUTDOOR EXPOSED (m
2
)
THE2400RA
6
4.8
4
THE3200RA
8
6.4
5.3