18
40.019.003 - rev 09 - 2018
IMA
ENGLISH
18
40.019.003 - rev. 06 - 2011
IMA
English
•
Maximum thermostat:
The maximum thermostat switches off the
heater when an overheating problem occurs.
The burner cannot be switched on again until
the thermostat has been reset by pressing
the U key for two seconds (Fig. 7).
The thermostat is set by the manufacturer. The
settings of the thermostat may only be changed
with approval of the manufacturer. Contact your
dealer for this.
2.7
Accessories
•
Flue with rain cover
•
Thermostat for room temperature
•
Distribution head for air outlet
•
Soft-starter set for gradual run-in of fan
•
Phase converter for always the correct
direction of rotation of the motor
•
Transformer set for electrical connections
without 0
•
Hour counter
•
Fuel filter with pre-heater
•
Fresh air connection for the burner
3
GETTING STARTED
3.1
Remove packaging
1. Remove the packaging from the heater.
2. Ride, lift or hoist the heater to the place of
use.
3.2
Installation
1. Make sure that the heater is placed
horizontally.
2. Connect the fuel hose to the fuel filter
(Fig. 8). Use a hose clamp.
Internal diameter of the hose (A): 10 mm.
3. Fill the tank with fuel.
4. Make sure there is sufficient distance
between the wall and the air inlet. Minimum
distance is 1 m.
5. Make sure that the heated air can flow
without obstruction. Minimum distance from
outlet to an obstacle is 5 m.
6. Check the ventilation surface area: for each
kW a ventilation surface of 25 cm
2
is needed.
7. Install the flue (1 m and a rain cover for use
outside).
8. Check the connection of the room
thermostat. Remove the cap only to connect
a room thermostat.
9. Make sure the rotary switch is in the “0”
position.
10. Check the supply voltage: see the
identification plate.
11. Fit a plug at the end of the power cable.
Check the direction of rotation of the fan (for
three-phase motor). See “Fan rotation
check”.
12. Put the plug in the socket.
13. Press the reset button (A) of the burner
(Fig. 6).
14. Reset the thermostat by pressing the U key
for two seconds (Fig. 7).
3.3
Fan rotation check
1. Set the rotary switch (A) to the “1” position
(Fig. 7). The fan starts rotating.
2. Feel if the fan blows air outside.
3. If the fan rotates in the wrong direction, set
the rotary switch to the “0” position.
4. Disconnect the electric power and contact the
dealer.
3.4
Power up
Power up for heating:
1. Open the fuel valve (B) (Fig. 8).
2. Set the rotary switch (A) to the “2” position
(Fig. 7) for the automatic mode. The fan
starts automatically after the heated air
reaches the set temperature.
Caution
Hoist the heater according to the
instruction on the stickers.
Caution
Use only gas oil.
Caution
•
Gas oil tends to thicken at low
temperatures. This can block the
filters. Add a maximum of 15%
paraffin to the fuel at temperatures
below -5
°
C, or keep the fuel frost-
proof, or use a tank heater.
•
Do not place the tank in the warm
air stream.
Caution
Only an authorised person is allowed to
put a plug on the power cable.
Caution
If the fan does not blow air outside, the
stream of air does not cool the heater.
The maximum thermostat will shut off
the heater.
Содержание IMA 111