WARNING
After running at high current, the anode and cathode plates can become
hot. Use caution when separating the gels and stacks from the plates. When continu-
ously processing multiple samples allow the cassette to cool for 30 minutes or use
multiple cassettes to avoid excessive cassette heating.
WARNING
Stainer use outside of the workflows described in this manual may put the
operator at risk of dangerous exposure to electrical shock. Do not use this instrument for
any purposes or in any configurations not described in this manual.
WARNING
The Pierce Power Station can contain dangerous electricity and is not
designed to be opened by the user. Disconnect all power to the Pierce Power Station
before maintenance by a qualified technician.
WARNING
Do not overfill the cassette with liquid. Excess liquid can overflow into the
base unit and possibly cause electric shock. Follow the appropriate instructions for
reagent amounts and empty any remaining liquid in the cassette upon run completion.
NOTE
A grounded circuit capable of delivering the appropriate current and voltage is required for instal-
lation. Electrical requirements can be located on the rear panel of the blotter base. The blotter electrical
system will adjust to the proper voltage for the respective country. Connect the blotter power cord to the
rear left side panel of the device and plug into a grounded power outlet.
ENVIRONMENTALLY FRIENDLY DISPOSAL
According to EU directive 2002/96/EC on electric and electronic equipment and its
implementation into national law, all electric equipments must be separately collected
and environmentally friendly recycled. Alternative disposal: If the owner of the electric
equipments does not return it to the manufacturer, he is responsible for proper disposal
at a designated collection point that prepares the device for recycling according to na-
tional recycling laws and regulations. This does not include accessories and tools without
electric or electronic components.
Life Science Research
Africa /Belgium/Europe/Middle East
+32 53 85 71 84
France
0 800 50 82 15
Germany
0228 9125650
Netherlands
076 50 31 880
Switzerland
0800 56 31 40
UK
0800 252 185
Email: [email protected]
thermoscientific.com/pierce
For other regions, visit
thermoscientific.com/piercedistributors
USA
+815-968-0747 or +800-874-3723
Customer Assistance
E-mail:[email protected]
thermoscientific.com/pierce
China
800 810 5118 or 400 650 5118
Customer Assistance
E-mail: [email protected]
2162583-A 09/14 Printed in USA
thermoscientific.com/pierce
© 2014 Thermo Fisher Scientific Inc. All rights reserved. Facebook is a registered trademark of Facebook, Inc. All other trademarks are the property of
Thermo Fisher Scientific Inc. and its subsidiaries.
Related Thermo Scientific
™
Products
84731 Pierce
™
1-Step Transfer Buffer
84783 Pierce
™
Western Blotting Filter Paper, 7cm x 8.4cm,
100 sheets (0.83mm thick)
84784 Pierce
™
Western Blotting Filter Paper, 8cm x 13.5cm,
100 sheets (0.83mm thick)
22840 Pierce
™
Mini Gel Power Staining Kit
22830 Pierce
™
Power System
22838 Pierce
™
Power Station
22834 Pierce
™
Power Blotter
22835 Pierce
™
Power Blot Cassette
22833 Pierce
™
Power Stainer
22836 Pierce
™
Power Stain Cassette
84747 Western Blot Roller
22841 Midi Gel Incubation Trays, 10 ea
22843 Mini Gel Incubation Trays, 10 ea
Blotter Electrical Parameter
Rating
Supply Voltage (VAC)
100-240
Frequency (Hz)
50/60
Maximum Power Rating (W)
168
Fuse (Power Center)
T3AL, 250V, 3A
Using the Pierce Power Station for the First Time
When turning on the Pierce Power Station for the first time, you
will see the “Cassette Type Activation” screen. Follow the direc-
tions on the screen and insert the Power Blot Cassette into the
Power Station to activate the Blot Cassette and staining software.
Remove the Power Blot Cassette and insert another cassette
type to activate other cassette and software application (e.g.,
blotting), or select “Done”.
Using the Pierce Power Blot Cassette for the First Time
First you must activate the blotting software. To do so, press
the “Settings” button on the Welcome screen. Press the down
arrow to view more menu options, and select the “Cassette
Type Activation” button. Previously activated cassette types will
appear on the screen with a check mark to the left. To activate
the Blot Cassette and blotting software, insert the Power Blot
Cassette into the Power Station and remove when instructed.
Press “Done” or activate an additional cassette type in the
same manner. For detailed instructions refer to the manual at
www.thermoscientific.com/pierce-power-system.