Warranty 

Warranty 

Seller warrants that the Products will operate or perform substantially in 
conformance with Seller's published specifications and be free from defects 
in material and workmanship, when subjected to normal, proper and 
intended usage by properly trained personnel, for the period of time set 
forth in the product documentation, published specifications or package 
inserts.  If a period of time is not specified in Seller’s product 
documentation, published specifications or package inserts, the warranty 
period shall be one (1) year from the date of shipment to Buyer for 
equipment and ninety (90) days for all other products (the "Warranty 
Period").  Seller agrees during the Warranty Period, to repair or replace, at 
Seller's option, defective Products so as to cause the same to operate in 
substantial conformance with said published specifications; provided that 
(a) Buyer shall promptly notify Seller in writing upon the discovery of any 
defect, which notice shall include the product model and serial number (if 
applicable) and details of the warranty claim; (b) after Seller’s review, Seller 
will provide Buyer with service data and/or a Return Material 
Authorization (“RMA”), which may include biohazard decontamination 
procedures and other product-specific handling instructions; and (c) then, 
if applicable, Buyer may return the defective Products to Seller with all 
costs prepaid by Buyer.  Replacement parts may be new or refurbished, at 
the election of Seller.  All replaced parts shall become the property of Seller.  
Shipment to Buyer of repaired or replacement Products shall be made in 
accordance with the Delivery provisions of the Seller’s Terms and 
Conditions of Sale.  Consumables, including but not limited to lamps, 
fuses, batteries, bulbs and other such expendable items, are expressly 
excluded from the warranty under this warranty.    

Notwithstanding the foregoing, Products supplied by Seller that are 
obtained by Seller from an original manufacturer or third party supplier are 
not warranted by Seller, but Seller agrees to assign to Buyer any warranty 
rights in such Product that Seller may have from the original manufacturer 
or third party supplier, to the extent such assignment is allowed by such 
original manufacturer or third party supplier.   

In no event shall Seller have any obligation to make repairs, replacements 
or corrections required, in whole or in part, as the result of (i) normal wear 
and tear, (ii) accident, disaster or event of force majeure, (iii) misuse, fault 
or negligence of or by Buyer, (iv) use of the Products in a manner for which 
they were not designed, (v) causes external to the Products such as, but not 
limited to, power failure or electrical power surges, (vi) improper storage 

Содержание INNOVA Series

Страница 1: ...INNOVA Series Instruction Manual Part Number 71 6417 5Aug2009...

Страница 2: ...ns terms and pricing are subject to change Not all products are available in all countries Please consult your local sales representative for details Thermo Fisher Scientific Air Quality Instruments 2...

Страница 3: ...ONCERNING START UP OPERATION CALIBRATION AND MAINTENANCE BE READ UNDERSTOOD AND FOLLOWED WARNING NOTATION CONVENTIONS Notices are used in this operator s manual to alert you to hazardous condi tions t...

Страница 4: ...s Waste Electrical Electronic Equipment WEEE Directive 2002 96 EC It is marked with the following symbol Thermo Fisher Scientific has contracted with one or more recycling disposal companies in each...

Страница 5: ...other product specific handling instructions and c then if applicable Buyer may return the defective Products to Seller with all costs prepaid by Buyer Replacement parts may be new or refurbished at t...

Страница 6: ...ANCE REPAIR SERVICE RELOCATION OR ALTERATION TO OR OF OR OTHER TAMPERING WITH THE PRODUCTS PERFORMED BY ANY PERSON OR ENTITY OTHER THAN SELLER WITHOUT SELLER S PRIOR WRITTEN APPROVAL OR ANY USE OF REP...

Страница 7: ...rt Up 5 Starting Up the Innova 6 Normal Operation 7 Turninging Off the Innova 8 Performing a Bump Test on Power Up 9 Chapter 3 Alarms Gas Alarms 11 Battery Alarms 12 Sensor Alarms 13 Pump Alarm 14 Dat...

Страница 8: ...echarging Ni Cd Batteries 46 Replacing Components 47 Appendix A Parts List and Accessories 53 Appendix B Interference Factors High Concentration of Combustible Gas 57 Relative Combustible Response Tab...

Страница 9: ...Time Weighted Average TWA levels You can display Peak readings STEL and TWA levels on command The Alarm circuit alerts you to dangerous gas conditions low battery conditions sensor failure datalog ful...

Страница 10: ...toxic versions only sensor failure temperature datalog Alarm Functions Alarm levels are user selectable in the Edit Alarms Screen Display Digital liquid crystal display LCD Displays up to four differ...

Страница 11: ...50 VOL N A N A O 2 0 1 VOL 0 to 30 0 VOL 19 5 VOL 23 5 VOL N A N A H 2 S 1 PPM 0 to 200 PPM 10 PPM 15 PPM 10 PPM 15 PPM CO 1 PPM 0 to 250 PPM 25 PPM 200 PPM 25 PPM 200 PPM Cl 2 0 1 PPM 0 to 9 9 PPM 0...

Страница 12: ...when sampling inert environments Moisture trap Glass bodied with a pleated paper filter that collects excess water that is drawn into or condensed in the sample hose Auxiliary hydrophobic filter A fi...

Страница 13: ...atterycompartment CAUTION Some toxic gas sensors require up to 15 minutes to stabilize after you install the batteries If your Innova includes a toxic gas sensor s do not turn on and use the Innova du...

Страница 14: ...Several messages appear during the warm up period starting with the model and software version Other screens displayed are Battery capacity on a scale from E empty to F full capacity for new alkaline...

Страница 15: ...the Innova is not alerting you to an alarm or failure After warm up is complete the Innova simultaneously displays the current gas concentration for all active sensors and the NORM icon This display s...

Страница 16: ...ent will auto range back to the next combustible range and allow the toxic sensor s to be displayed To change the combustible gas range press and release the RANGE button The unit will beep once and s...

Страница 17: ...p cycle The display will read AIR ADJUST NOW The screen will blink on and off with alternating lights prompting the operator to perform a fresh air adjust 3 Press and hold the AIR button for three sec...

Страница 18: ...0 second count After the 30 second count has elapsed an ALARMS ACTIVE message will display briefly audible alarms will be enabled and the Innova will return to the normal operating mode NOTE If the In...

Страница 19: ...arms The backlight automatically turns on during all gas alarms Gas Alarm Indications Table 3 1 lists the indications for each type of gas alarm Table 3 1 Alarm Indications Gas Alarms Alarm Display Li...

Страница 20: ...ises above for decreasing O2 Battery Alarms This section describes alarm indications display messages and response for the following battery alarms Low Battery and Replace Battery The backlight automa...

Страница 21: ...normal operation or calibration Alarms that occur during calibration are described in Chapter 5 Calibration 1 Examine the display screen to determine which sensor is failing The failing sensor displa...

Страница 22: ...he pump icon spinning 3 If the pump restarts and the monitor functions normally the problem was momentary If the indications remain turn the monitor off then investigate the probe hose or internal flo...

Страница 23: ...enu and clear the datalog see Chapter 4 User Program Clear Log Memory Temperature Alarm The Innova has an alarm to alert the user that the unit is being operated at a temperature that exceeds its oper...

Страница 24: ...16 71 6417 Innova Series Operator s Manual...

Страница 25: ...isplay Menu Advanced Features Menu Datalog Features Menu The user navigates through the user program by using the three buttons ON OFF AIR RANGE The right arrow is used to accept within the menu The u...

Страница 26: ...through the menu press the button Continue to scroll through the screens to display the desired information clear Peak Readings or change an Operator or User ID 3 To exit the program press either or...

Страница 27: ...nts down from 3 seconds and then displays BEGIN CAL Press to scroll to ADVANCED FEATURES or DATALOG MENUS 2 Stop scrolling at the desired screen and press to accept The display now reads PASSWORD LOGW...

Страница 28: ...d both the AIR and RANGE buttons for 3 seconds The screen displays FEATURES MENU and counts down from 3 seconds 2 The first screen displayed after the countdown is BEGIN CAL Press the button then pres...

Страница 29: ...our version of Innova HC O2 TOXIC1 TOXIC2 4 Press or to continue scrolling through the Advanced Features Menu O2 ALARM CONFIGURATION This option allows you to set the oxygen alarms High and Low to eit...

Страница 30: ...cause momentary false alarms Selection options are 0 seconds no delay 1 3 or 5 seconds The default setting is 0 SECOND DELAY 1 Press to accept ALARM DELAY 2 Press or to scroll between settings 0 1 3 O...

Страница 31: ...d Features MenuCal Interval Selection This sets the number of days between calibrations NOTE The number of days left until calibration is displayed during the warm up cycle When the Innova is due for...

Страница 32: ...sponding sensor s are installed in the proper location WARNING The Innova does not display gas readings initiate alarms compute averages or store data for OFF sensor s To change the sensor select sett...

Страница 33: ...he screen AUTOCAL GAS VAL All four gases and their values will display The cursor and reading will flash for HC if installed and ON 2 Press or to change value up or down 3 Once you ve reached the desi...

Страница 34: ...To change the setting from the Advanced Features Menu 1 Press at the screen COMFORT ALERT 2 Press or to scroll through the options 3 Press to accept the setting Press to continue scrolling through the...

Страница 35: ...E PASSWORD or CHANGE LOGWORD The screen will display either three asterisks or the three digit code with the cursor on the first character 2 Press or to change the first character of the code You have...

Страница 36: ...onds The screen displays FEATURES MENU and counts down from 3 seconds 2 The first screen displayed after the countdown is BEGIN CAL Press the button twice The display will read DATALOG MENUS 3 Press t...

Страница 37: ...user to identify the Operator and Location of personnel operating the Innova The information is stored in the datalogging memory for retrieval at a later time The Innova has three IDs the user can upd...

Страница 38: ...ce number is displayed on the bottom line Press the button to continue scrolling through the various operators and locations you want to display or update Then press to edit or update the screen LOG M...

Страница 39: ...Menu LOG INTERVAL This parameter instructs the Innova how often to record data in the datalog You have the option of 5 15 30 60 90 300 or 900 seconds The factory default setting is LOG EVRY 60 SEC To...

Страница 40: ...2 Press and hold and for 3 seconds and release The display reads CLEARING LOG and beeps for several seconds When complete the display indicates LOG CLEARED NOTE If you do not want to clear the log pre...

Страница 41: ...if hazardous conditions exist Preparing the Calibration Kit Perform the following steps to prepare the Innova calibration kit WARNING LEL response will vary for different gases For best accuracy LEL...

Страница 42: ...pplied The default value is that set in the Auto Cal Gas Values screen see Chapter 4 User Program Setting Auto Cal Gas Values Auto Calibration WARNING Calibrate the Innova in a fresh air environment e...

Страница 43: ...age FEATURES MENU appears on the display and counts down from 3 seconds and then displays BEGIN CAL 2 Press to accept The display reads CAL WORD and The cursor is on the first asterisk 3 Press or to s...

Страница 44: ...chapter for corrective action 7 Remove the tubing from the probe After fresh air has been detected the display will alternate between ALARMS SILENCED and the readings and then return to the normal ope...

Страница 45: ...on WARNING Calibrate the Innova in a fresh air environment environment known to be free of combustible and toxic gases and of normal oxygen content 1 Hold down the AIR button for 3 seconds until the d...

Страница 46: ...is detected during this period the screen returns to BEGIN CAL 9 Attach the tubing from the regulator to the probe tube the Innova will draw gas from the gas cylinder When gas is detected the display...

Страница 47: ...mplete Sensor Failed Alarm If you attempt to air adjust or calibrate a faulty sensor the Innova alerts you with a Sensor Failed Alarm INDICATIONS The backlight turns on automatically The gas reading i...

Страница 48: ...conclusion of the calibration period RESPONDING TO A WEAK SENSOR 1 If you are manually calibrating the Innova verify that you are correctly adjusting the gas concentration to match the concentration o...

Страница 49: ...is in continual or everyday use Thermo Fisher Scientific recommends that you perform preventive maintenance procedures more often than suggested in the following sections Daily BATTERIES The Innova s...

Страница 50: ...e for a few seconds The pump shuts off PUMP FAILED and PRESS CLEAR alternate with the gas readings display the spinning icon changes to an X The audible alarm sounds every second alternating beeping P...

Страница 51: ...scolored WARNING Operation of instrument without probe filter assembly attached will result in pump damage and possible impaired performance Do not operate without probe filter assembly attached Troub...

Страница 52: ...tinues contact Thermo Fisher Scientific for further instruction Unable to use the battery charger as a continuous operation adapter You cannot operate the Innova with the battery charger continuous op...

Страница 53: ...eplace the sensor as described later in this chapter 3 If the difficulties continue contact Thermo Fisher Scientific for further instruction Unable to calibrate a sensor O 2 sensor only You cannot fre...

Страница 54: ...the voltage listed on the battery charger is the same as the AC outlet 115V or 220V then plug the charger into the outlet 3 Plug the other end of the charger into the CHGR jack at the side of the Inn...

Страница 55: ...to secure the battery lid in place 1 Turn off the Innova by pressing and holding the ON OFF button while the Innova sounds three beeps 2 Turn the captive screw at the middle of the battery compartmen...

Страница 56: ...ies Some toxic gas sensors require up to 15 minutes to stabilize after you install the batteries If your Innova includes a toxic gas sensor s do not turn on and use the Innova during this period If th...

Страница 57: ...rs contain sulfuric acid The O2 sensor contains an alkali solution Figure 6 2 Innova Series Sensor Locations and Connection Assignments 1 Turn off the Innova CAUTION To avoid damage to internal circui...

Страница 58: ...to damage the sensor housing or the flow block 5 Using your fingers tilt the sensor from side to side to loosen it then pull the sensor straight out of its flow block cavity see Figure 6 3 6 Insert t...

Страница 59: ...pump wire connector from the main board socket labeled PUMP 4 Remove the nut that secures the pump bracket to the pump then remove the bracket 5 Remove the pump from the flow block by rocking it back...

Страница 60: ...from the slip on barbs on the filter 4 Push the tubes onto the barbs on the new filter close and secure the Innova and re install batteries Replacing the Probe s Hydrophobic Filter 1 Unscrew the probe...

Страница 61: ...0042 Pump 30 0044 Kit rebuild pump 30 0042 30 0042 01 33 0152 01 Filter Hydrophobic for 80 0187 probe 33 0160 Filter internal 33 1031 Cotton ball pkgs of 24 for 80 0187 probe 49 1201 Battery alkaline...

Страница 62: ...inch with hydrophobic filter 80 0211 Moisture trap 80 0405 Dilution fitting 50 80 0504 Hose teflon 3 feet for Cl2 Fuel Soil Vapor 80 0505 Hose polyurethane 5 feet 80 0511 Hose polyurethane 10 feet 80...

Страница 63: ...5 PPM PH3 58 liter 81 0226 01 Cal kit O2 81 0226 02 Cal kit CH4 81 0226 03 Cal kit CO 81 0226 04 Cal kit CH4 Land Survyor 81 0226 05 Cal kit Hexane Soil Vapor 81 0226 06 Cal kit Hexane O2 Fuel Vapor 8...

Страница 64: ...al kit CH4 O2 HCN NO 81 0228 05 Cal kit CH4 O2 HCN PH3 81 0228 06 Cal kit CH4 O2 NH3 NO2 81 0228 07 Cal kit CH4 O2 NH3 PH3 81 0228 08 Cal kit CH4 O2 NO NO2 81 0228 09 Cal kit CH4 O2 NO PH3 81 0228 10...

Страница 65: ...LEL readings Such compounds even in small proportions should be avoided Verification checks on known gas samples are necessary if the possibility of exposure to these compounds exists High Concentrati...

Страница 66: ...e enough to arrest flames from combustible gas in oxygen Such mixtures will also cause a high oxygen alarm WARNING Do not attempt to use the Innova on samples of combustible gas in oxygen for example...

Страница 67: ...1 0 3 3 1 0 Methyl Chloroform 7 5 0 68 1 6 4 9 1 5 Methyl Ethyl Ketone 1 4 1 09 2 5 1 7 0 52 Pentane 1 5 0 71 1 7 1 0 0 30 Propane 2 1 0 56 1 3 1 3 0 39 Propyl Acetate 1 7 0 77 1 8 1 4 0 42 Propyl Alc...

Страница 68: ...60 71 6417 Innova Series Operator s Manual...

Страница 69: ...nge The display will show the legend GAS HI following the gas reading while in this range The GAS HI range may also be entered manually from the LEL LO range by pressing the RANGE button twice If it i...

Страница 70: ...ctrical discharges or sparks from metal tools that can ignite such mixtures The relationship between ranges is correct only for methane Some rough approximations may be made for gases such as propane...

Страница 71: ...cess by performing an Auto Calibration The TC sensor will be ignored during the multi gas calibration 3 When the multi gas Auto Calibration is complete a double beep prompts the user to begin the TC s...

Страница 72: ...te list of replacement parts and accessories Replacement Parts 30 0042 01 Pump Land Surveyor 61 0124 Sensor Thermal Conductivity 81 0012 Cylinder 50 LEL CH4 17 liter 81 0226 04 Cal kit CH4 81 0228 12...

Страница 73: ...gas levels exceed acceptable levels additional inspection including performing a dissolved gas analysis is required to determine fault condition and appropriate action If oxygen detection is required...

Страница 74: ...orrect reading For testing oxygen content in transformers the dilution fitting can be removed This will allow you to determine if there is oxygen present This test however can only be performed with t...

Страница 75: ...when complete and close valve on bag NOTE When testing for oxygen content either remove the dilution fitting from the Innova Transformer Gas Tester or place your finger over the small orifice on the...

Страница 76: ...List in Appendix A for a more complete list of Innova replacement parts and accessories common to all models 80 0405 Dilution fitting 50 81 0013 Cylinder 1 H2 12 O2 in N2 81 0227 21 Cal kit H2 O2 Tra...

Страница 77: ...to respond only to non methane combustible gases This allows the user to discriminate between methane and non methane hydrocarbons Table C 2 Sensor Specifications Sensor Sensor Type Detection Range Wa...

Страница 78: ...d the mode may be changed by pressing the RANGE button twice To change the hydrocarbon range from LEL to PPM press the RANGE button once CAUTION Note that if the mode of operation is changed to ME ope...

Страница 79: ...e Auto Cal Gas Value screen must match the multi gas mixture see Chapter 4 User Program Setting Auto Cal Gas Values NOTE The Innova Soil and Fuel Vapor Monitors use a 3 foot teflon lined hose to minim...

Страница 80: ...tarts to scroll then the display will read DONE once the fresh air reading for all active sensors is complete NOTE After you complete the fresh air adjustment a XXX may appear on the display screen in...

Страница 81: ...ings If you choose to abort press to scroll to ABORT then to accept the abort option The display will read CAL ABORTED and then alternate between REMOVE GAS and the gas readings NOTE A WEAK or FAIL fl...

Страница 82: ...racter 4 Repeat steps 3 and 4 until all three characters are accepted If correct the next display reads AUTOCAL If the CalWord is incorrect the display reads BEGIN CAL message Begin at step 1 to start...

Страница 83: ...complete list of all replacement parts and accessories 61 0123 Sensor Combustible LEL PPM 65 0613 Sensor Oxygen Fuel Vapor only 80 0504 Hose 3 teflon lined 81 0007 Cylinder 40 LEL Hexane 81 0078 Cylin...