background image

34

[email protected] 
www.thermofisher.com

1508990-05

thermofisher.com

 
© 2018 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher 
Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products 
are available in all countries. Please consult your local sales representative for details.

Thermo Fisher Scientific Oy

Ratastie 2
01620 Vantaa
Finland

Содержание F1-ClipTip

Страница 1: ...1 Thermo Scientific F1 ClipTip Single Channel Multichannel Instructions for Use Us er Ma nu al ...

Страница 2: ...formation enclosed in the product package or contact the manufacturer at info pipettes thermofisher com to ensure correct and safe use The CE mark covers the system containing the CE marked F1 ClipTip pipette and the CE marked ClipTip pipette tips Product specifications are subject to change without prior notice ClipTip is a registered trademark of Thermo Fisher Scientific Inc and its subsidiaries...

Страница 3: ...3 CONTENTS 1 INTRODUCTION 4 2 PACKAGE 5 3 MAIN ILLUSTRATION 5 4 SAFETY 6 5 OPERATION 7 6 CALIBRATION AND ADJUSTMENT 9 7 MAINTENANCE 11 8 STERILIZATION 16 9 TROUBLESHOOTING 17 10 APPENDICES 18 ...

Страница 4: ...4641210N F1 ClipTip 20 200 µl 20 200 µl 0 2 µl yellow ClipTip 200 4641220N F1 ClipTip 30 300 µl 30 300 µl 1 µl orange ClipTip 300 4641230N F1 ClipTip 100 1000 µl 100 1000 µl 1 µl blue ClipTip 1000 F1 ClipTip Fixed Volume Single Channel Cat no Description Volume range Color code Compatible ClipTip 4651280N F1 ClipTip 10 µl 10 µl dark blue ClipTip 12 5 Ext 4651200N F1 ClipTip 20 µl 20 µl dark blue C...

Страница 5: ...items 1 F1 ClipTip pipette 2 Service tool 3 Multichannel service tool 4 Tip fitting tool 5 Bag of grease 1g Order No 3300200 6 Instructions for Use 7 Calibration certificate Warranty Certificate 8 O ring Order No 2214930 Single Channel Pipette Scp 300 3 pcs Order No 2215540 Scp 1000 3 pcs Order No 2214920 Multichannel Pipette Mcp 12 pcs 3 Main Illustration F1 ClipTip F1 ClipTip F1 ClipTip 1 2 3 6 ...

Страница 6: ...therimide PA polyamide PVDF polyvinyldenfluoride EPDM ethylene propylene diene rubber FVM fluorosilicone rubber Steel stainless steel PPSU Polyphenylsulfone CLIPTIP TIPS Tip PP polypropylene Filters PE polyethylene 4 Safety Cautions are marked with this symbol 4 1 Intended use The intended use of the device is to transfer liquids in the volume range of 0 1 µl to 1000 µl The F1 ClipTip pipette and ...

Страница 7: ...sal For waste disposal instructions contact your local environmental agency For more information please contact us at info pipettes thermofisher com Regarding the original packaging and packing materials use the recycling operators known to you For more information contact your local Thermo Fisher Scientific representative 5 Operation Cautions for incorrect operation For optimum performance make s...

Страница 8: ...to a ClipTip in a rack and press until the tip is attached The tip is attached when it snaps over the tip fitting flange Do not use excessive force when attaching the tips as the device requires minimum attachment force Picture 4a 2 Lift the pipette 3 If the tip is not attached repeat Steps 1 and 2 20 1000µl modes 1 To attach the tip guide the pipette into a ClipTip in a rack and press with light ...

Страница 9: ...oper functionality it is recommended to press the plunger several times to the final stop step 3 in picture before dosing the sample liquid This releases the piston and re distributes the lubricant NOTE If the super blow out piston is jammed increased force might be required to release it Ensure that plunger moves to the down position Picture 6 For more information about different pipetting techni...

Страница 10: ...ays adjusted according to the delivery of the selected volume Use of the forward pipetting technique is recommended The maximum permissible errors are valid for the forward pipetting method It is recommended to use the ISO8655 calibration limits in Appendix 3 or user defined specifications Procedure 1 Do 10 pipettings at the minimum volume or 10 of the maximum volume 2 Do 10 pipettings at the maxi...

Страница 11: ...stances being aspirated and dispensed also vary tremendously among laboratories In order to maintain proper care of the pipette it is the laboratory s responsibility to develop a proper maintenance program that meets its specific needs and requirements When the F1 ClipTip is not in use make sure it is stored in an upright position We recommend a pipette stand for this purpose When shipping the dev...

Страница 12: ... from the handle with the tip cone 11 Then turn the tip cone upside down and tap all parts from it 7 2 2 Disassembly of single channel pipettes 300ul and smaller 1 Press the tip ejector 4 1 Rotate the tip ejector 10 counterclockwise and pull it out Picture 12 NOTE If you want to service only parts inside cylinder go to step 4 But then use the bigger slot in service tool 2 Remove the tip fitting 5 ...

Страница 13: ...er the piston Slide the tip fitting over the piston assembly and screw it into place 1 10μl 10μl Fixed First slide spring support 16 into tip cone 11 Slide spring 13 over piston 12 Carefully place the piston assembly in the tip cone Very carefully place the tip cone assembly in the handle so that the head of the piston comes out of the head of the tip cone Place the piston through O ring seal 18 S...

Страница 14: ...ck that there is no gap between tip fitting and cylinder Picture 13 Be careful not to overtighten the tip fitting This may damage the thread in the pipette 7 2 5 Disassembly of multichannel pipettes 1 Remove the tip fittings Picture 8 To remove the tip fitting place the star shaped end of tool 3 picture 9 into the end of the fitting Turn the tool counterclockwise to unscrew the tip fitting picture...

Страница 15: ...ll down and remove the tip ejector part of the module II 7 2 6 Service instructions for multichannel pipette tip cones cylinders Volume 1 10 µl 1 Unscrew the tip fittings I Picture 16 2 Remove O rings 37 3 Clean pistons 31 and the O rings with a dry nap free cloth 4 If necessary change O rings 37 5 Grease the O rings with the lubricant provided in the pipette package 6 Screw the tip fittings back ...

Страница 16: ...ne bag contains a matched set of tip cones Place aligning studs to the same side when assembling the module Picture 18 Make sure that the tip fittings are aligned in same level adjust if necessary 8 Sterilization Before autoclaving disassemble the tip fitting from the tip cone and autoclave them separately After autoclaving the tip cone and tip fitting must be cooled to room temperature for at lea...

Страница 17: ...ing a highly volatile solvent repeatedly Pipette dropped on the floor etc One sided force applied to the knob when adjusting the volume with one hand Possible action Re attach tighten the tip fitting or replace with new tip fitting s using the tool Discard the tip Change the O ring Attach firmly Clean the tip cones and attach new tips Clean and grease the O ring and cylinder Grease accordingly Cha...

Страница 18: ...1 0030 1 0030 21 0 1 0028 1 0029 1 0029 1 0030 1 0031 1 0031 1 0031 21 5 1 0030 1 0030 1 0031 1 0031 1 0032 1 0032 1 0032 22 0 1 0031 1 0031 1 0032 1 0032 1 0033 1 0033 1 0033 22 5 1 0032 1 0032 1 0033 1 0033 1 0034 1 0034 1 0034 23 0 1 0033 1 0033 1 0034 1 0034 1 0035 1 0035 1 0036 23 5 1 0034 1 0035 1 0035 1 0036 1 0036 1 0036 1 0037 24 0 1 0035 1 0036 1 0036 1 0037 1 0037 1 0038 1 0038 24 5 1 0...

Страница 19: ...0 1 5 0 30 1000 4651270N 1000 3 0 0 30 3 0 0 30 1000 Order No Range Volume Inaccuracy Imprecision Compatible µl µl SD µl CV ClipTip 4641310N 0 1 2 µl 2 0 050 2 50 0 040 2 00 12 5 Ext 0 2 0 024 12 00 0 020 10 00 0 1 0 033 33 00 0 025 25 00 4641320N 1 10 µl 10 0 100 1 00 0 050 0 50 12 5 Ext 1 0 025 2 50 0 020 2 00 4641180N 2 20 µl 20 0 20 1 00 0 08 0 40 20 2 0 06 3 00 0 05 2 50 4641190N 5 50 µl 50 0...

Страница 20: ...35 0 70 50 5 0 25 5 00 0 10 2 00 4661130N 10 100 µl 8 100 1 30 1 30 0 50 0 50 200 10 0 50 5 00 0 20 2 00 4661140N 30 300 µl 8 300 3 0 1 00 0 9 0 30 300 30 1 5 5 00 0 6 2 00 4661220N 1 10 µl 12 10 0 240 2 40 0 160 1 60 12 5 Ext 1 0 120 12 00 0 080 8 00 4661160N 5 50 µl 12 50 0 75 1 50 0 35 0 70 50 5 0 25 5 00 0 10 2 00 4661170N 10 100 µl 12 100 1 30 1 30 0 50 0 50 200 10 0 50 5 00 0 20 2 00 4661180...

Страница 21: ... 0 30 0 3 200 yellow 10 0 80 8 0 0 30 3 0 30 300 µl 8 12 300 8 0 2 7 3 0 1 0 300 orange 30 8 0 26 7 3 0 10 0 Thermo Scientific F1 ClipTip Variable Volume Single Channel Thermo Scientific F1 ClipTip Fixed Volume Single Channel Thermo Scientific F1 ClipTip Variable Volume Multichannel Range Volume Inaccuracy Imprecision Compatible Color µl µl SD µl CV ClipTip code 0 1 2 µl 2 0 080 4 0 0 040 2 0 12 5...

Страница 22: ... spare parts Available as a spare part See model specific order numbers on page 30 2 1062930 Multichannel service tool 50 Module 42 Tip cone assembly 1 1062800 Service and adjustment tool 5 Tip fitting 3 0300070 Tip fitting tool ...

Страница 23: ...23 All 1 300µl 2 20µl 20 µl Fixed 12 14 15 16 17 18 19 20 21 13 11 10 8 9 5 2 5 1 5 0 1 2µl 11 13 16 10 28 20 27 21 12 1 10µl 10 µl Fixed 11 13 16 10 18 21 12 ...

Страница 24: ...24 10 100µl 12 13 14 15 16 17 5 50µl 25 50 µl Fixed All 1 300µl 12 14 15 16 17 18 19 20 21 13 11 10 8 9 5 2 5 1 5 ...

Страница 25: ...25 100 1000µl 500 1000 µl Fixed 12 13 14 15 16 17 6 8 9 5 2 5 1 5 10 11 30 300µl 250µl Fixed 20 200µl 100 200 µl Fixed 12 13 14 15 16 17 12 13 14 15 16 17 11 10 8 9 5 2 5 1 5 All 1 300µl ...

Страница 26: ...26 50 8 ch 1 10 µl 15 12 13 16 17 31 33 30 37 43 46 18 21 21 23 32 27 22 21 21 ...

Страница 27: ...27 50 12 ch 1 10 µl 15 46 23 31 33 30 37 32 18 21 20 22 21 20 12 13 16 17 43 27 ...

Страница 28: ...28 50 15 12 13 16 17 31 33 30 37 35 43 46 18 21 20 22 42 23 19 25 26 24 32 38 39 40 41 27 5 2 5 1 5 8 ch 5 50 µl 10 100 µl 30 300 µl 21 20 ...

Страница 29: ...29 15 12 13 16 17 43 46 18 21 20 22 31 33 42 32 23 19 25 26 34 35 36 30 24 27 50 5 2 5 1 5 12 ch 5 50 µl 10 100 µl 30 300 µl 21 20 ...

Страница 30: ...3430 17 1030160 42 2216120N 30 300µl 250µl Fixed 5 2216160 4 pcs 5 1 2214930 3 pcs 5 2 1033430 17 1033330 42 2216130N 100 1000µl 500µl 1000µl Fixed 5 2216190 4 pcs 5 1 2215540 3 pcs 5 2 1033430 17 1030020 42 2216220N Multichannel 8 ch 12 ch 5 2216170 8 pcs 5 2216180 12 pcs 5 1 2214920 12 pcs 5 2 1033430 37 1030060 1 pcs 42 2214400 5 50µl 12 pcs 42 2214410 10 100µl 12 pcs 42 2214420 30 300µl 12 pcs...

Страница 31: ...420313 ClipTip Filter 200 200 µl 10x96 rack 94420513 ClipTip Filter 300 300 µl 10x96 rack 94420613 ClipTip Filter 300 Ext 300 µl 8x96 rack 94420713 ClipTip Filter 1000 1000 µl 8x96 rack All ClipTip tips are certified to be free from RNase DNase DNA ATP and endotoxins Thermo Scientific ClipTip reloads Code ClipTip Volume Qty 94410217 ClipTip 20 20 µl 10x96 insert 94410218 ClipTip 20 sterile 20 µl 1...

Страница 32: ...210N F1 ClipTip 25µl fixed volume x 4651220N F1 ClipTip 50µl fixed volume x 4651230N F1 ClipTip 100µl fixed volume x 4651240N F1 ClipTip 200µl fixed volume x 4651250N F1 ClipTip 250µl fixed volume x x 4651260N F1 ClipTip 500µl fixed volume x 4651270N F1 ClipTip 1000µl fixed volume x 4661210N F1 ClipTip 8 ch 1 10µl x 4661120N F1 ClipTip 8 ch 5 50µl x 4661130N F1 ClipTip 8 ch 10 100µl x 4661140N F1 ...

Страница 33: ...33 Multichannel stand 9420390 F stand 9420400 Reagent reservoir 100 ml 95128085 Reagent reservoir 25 ml 95128093 Reagent reservoir 25 ml divided 951228095 Appendix 7 Pipette accessories ...

Страница 34: ...rights reserved All trademarks are the property of Thermo Fisher Scientific Inc and its subsidiaries Specifications terms and pricing are subject to change Not all products are available in all countries Please consult your local sales representative for details Thermo Fisher Scientific Oy Ratastie 2 01620 Vantaa Finland ...

Отзывы: