background image

Thermo Scientific Harris Ultra-Low Temperature Freezers

 Installation and Operation

11

9 Optional Equipment

The following equipment is available for some freezer models 
either as factory-installed or as field-installed options. Refer to 
the Accessories section on page 11 for more information on these 

and other options, including inventory racks and storage boxes.

For additional information, contact your representative or 
Customer Sales at 1-800-221-4201.

9.1 Backup Protection Devices

Liquid Nitrogen and Liquid CO

2

 systems are available to protect 

your product in case of a prolonged power failure. These systems 
are powered by a rechargeable battery with a built-in automatic 

charger. Refer to Section 6.1 on page 6 for additional 
information.

9.1.1

Liquid Nitrogen (LN

2

)

This system uses portable and locally refillable bottles. These 
containers keep the liquid at low temperature and pressure by 
continually venting a small amount of gaseous N

2

. You must 

check the liquid level indicator daily to assure an adequate 
emergency supply.

9.1.2

Liquid CO

2

This system uses portable and locally refillable bottles that are 
not vented and have a virtually unlimited standby life unless they 
develop a leak. These containers hold liquid at room temperature 
and high pressure. Several bottles can be connected together, 

increasing the effective length of standby refrigeration.

The coldest center air temperature achievable with CO

2

 backup 

is -70º C. For colder temperatures, use LN

2

.

9.2 Circular Chart Recorder

Chart recorders can be factory or field installed. If your freezer 
does not have a recorder, you can order one for panel, wall, or 
freestanding mounting.

9.3 Remote Alarm

The remote alarm terminals on the back of the freezer are 
connected to freezer internal dry contacts. You can connect a 
remote alarm package with a separate 24 volt power supply.

10 Accessories

Note:

For accessories and options not described herein, or for special modifications, contact Sales.

Inventory Rack Capacity Chart for all Freezers

Rack Catalog No. 

(Rack Quantity) Box Size in.

Cubic Foot Capacity

1

3.1

4.5

6.8

10.3

13.7

17.1

20.5

13.4

17.2

20.2

24.4

For  Chest Freezers

5972,  Full  Rack,  (7)  2  in.  boxes

9

12

5973,  Full  Rack,  (5)  3  in.  boxes

9

12

5978, Full Rack, (11) 2 in. boxes

12

18

24

30

36

6096, Full Rack, (8) 3 in. boxes

12

18

24

30

36

6230, Half Rack, (6) 2 in. boxes

24

36

48

60

72

6231, Half Rack, (4) 3 in. boxes

24

36

48

60

72

For  Upright Freezers

6112-1, (12) 2 in. or (9) 3 in. boxes

20

6113-1, (16) 2 in. or (12) 3 in. boxes

20

25

30

Содержание DLT

Страница 1: ...Installation and Operation Manual Thermo Scientific Harris DLT SLT and ELT Ultra Low Temperature Freezers...

Страница 2: ...d trademark of Armacell International GmBH All other trademarks are the property of Thermo Fisher Scientific Inc and its subsidiaries 2007 Thermo Fisher Scientific All rights reserved Suva is a regist...

Страница 3: ...ocking the Door 2 4 5 2 Unlocking the Door 2 4 5 3 Opening the Door 2 4 6 Compressor Mounts 3 4 7 Pressure Equalization Port 3 5 Operation Harris DLT and SLT Series Freezers 4 5 1 Control Panel Featur...

Страница 4: ...arm 9 8 Maintenance and Troubleshooting 10 8 1 Condenser Maintenance 10 8 1 1 Cleaning the Condenser 10 8 1 2 Cleaning the Condenser Filter 10 8 2 Gasket Maintenance 10 8 3 Defrosting the Freezer 10 8...

Страница 5: ...the compressors to operate for a prolonged time period Attempting to utilize this freezer improperly may jeopardize user product safety or cause undue stress or damage to the refrigeration compressors...

Страница 6: ...the prong is removed the warranty is invalidated 4 3 Voltage Safeguard Freezers are equipped with a standard built in Voltage Safeguard circuit to detect and adjust low line voltage The Voltage Safeg...

Страница 7: ...qualization Port When an upright ultra low temperature freezer door is opened room temperature air rushes into the storage compartment When the door is closed the fixed volume of air is cooled rapidly...

Страница 8: ...rease temperature values 18 Increment Pad Use this pad to increase temperature values The following indicators are available only when the freezer is equipped with the optional backup system refer to...

Страница 9: ...the Warm Alarm Set Point 4 Release both pads when the digital temperature display window shows the correct set point value When the cabinet temperature drops below the Warm Alarm setting turn the key...

Страница 10: ...serve the following precautions when using liquid CO2 and LN2 backup systems WARNING If a CO2 or LN2 cylinder falls and a valve is knocked off the cylinder becomes a deadly and completely unguided mis...

Страница 11: ...wer WARNING You must push the Power Switch to the ON position in order to activate the backup system 6 4 System Status Lights In addition to the backup control system the built in backup system includ...

Страница 12: ...ty 5 6 6 5 7 5 14 ft3 Empty 5 4 6 2 7 0 1 2 Full 4 8 5 5 6 3 1 2 Full 4 5 5 2 5 9 Full 3 5 4 2 4 8 Full 3 4 3 9 4 4 17 ft3 Empty 6 5 7 5 8 7 17 ft3 Empty 6 2 7 1 8 1 1 2 Full 5 5 6 3 7 3 1 2 Full 5 3...

Страница 13: ...t Point and simultaneously press and hold the Set Point Display button The temperature display changes to read the existing set point value 2 Turn the set point screw clockwise for a colder setting an...

Страница 14: ...inet 2 Turn off the freezer 3 Open the outer door and all inner doors 4 Let the freezer stand with doors open for at least 24 hours This allows both the interior and foamed refrigerant system to warm...

Страница 15: ...a virtually unlimited standby life unless they develop a leak These containers hold liquid at room temperature and high pressure Several bottles can be connected together increasing the effective len...

Страница 16: ...oxes for all chest models except 3 1 and 4 5 cu ft 6230 Single split rack holds 4 3 in boxes for all chest models except 3 1 and 4 5 cu ft 6231 Basket Rail Kit for 6 8 cu ft chest freezers 6217 Basket...

Страница 17: ...rogen cylinder Description Catalog No Temperature recorder 6 in circular chart seven day drive panel mounted for 40 C to 95 C Not available for Harris Classic chest models which use 6383 6 Factory ins...

Страница 18: ...rdering 5612 Deluxe Electronic Remote Alarm System User programmable to sound alarm in the event of temperature rise or power failure Can dial up to four telephone numbers to advise of alarm condition...

Страница 19: ...die unter diese RoHS Anweisungfallen finden Sie unter www thermo com Conformit WEEE Questo prodotto deve rispondere alla direttiva dell Unione Europea 2002 96EC in merito ai Rifiuti degli Apparecchi...

Страница 20: ...can be found on the dataplate attached to the equipment If available please provide the date purchased the source of purchase manufacturer or specific agent rep organization and purchase order number...

Страница 21: ...Thermo Fisher Scientific Inc 275 Aiken Road Asheville NC 28804 United States www thermofisher com 38257H01 Rev J...

Отзывы: