Run

Stop

Run

Stop

Press “      ” button again and the 
instrument will slow down until it stops. 
The instrument will then be in standby 
and the two display windows will show 
the set values.

2.  Timer Mode
Press “      ” button and the instrument 
will

 start running with the specified 

settings and the RUN indicator light will 
be on. 

The TIME display window will 

show the remaining time and the SPEED 
display window will show the current 
speed. Press “      ” button again and the 
instrument will slow down until it stops.
The instrument will then be in standby 
and the two display windows will show 
the set values.

Finish Operation

 

After the operation is finished, press the 
power switch at the back right side the 
instrument and put it into the “O” state. 
Unplug the instrument and store the 
instrument according to the storage 
guide.

Note: 

To ensure shaking operation 

smooth and steady, it may take 1minute 
for the microprocessor control system to
accelerate the tray to the set speed. 

  

Run

Stop

Run

Stop

5.4 Settings

Time Settings

1.  Continuous mode
Press the Time setting knob. When the 
Time display window starts flashing, 
turn the knob to  increase or decrease 
the time to 00:00 and then press the  
knob within 5s. 

2.  Timer mode
Press the Time setting knob. When the 
number shown on the Time display 
window starts flashing, turn the knob to  
increase or decrease the time value. 
Press the  knob when the time shown on 
the Time display window reaches the set 
value within 5s.  

Speed Settings

Press the Speed setting knob. When the 
Speed display window starts flashing, 
turn the knob  to increase or decrease 
the speed value. Press the  knob when 
the speed shown on the Speed display 
window reaches the set value within 5s. 

Run and Stop

1.  Continuous Mode
Press“      ”button and the instrument will 
start running with the specified settings 
and the RUN indicator light will be on. 
The TIME display window will show the 
cumulative time and the SPEED display 
window will show the current speed. 

Alarm System

Err1: If running speed does not match 
the setting speed, the instrument will 
have a three-time reboot, and after the 
three reboots failed, there will be a 
buzzer, and then Err1 will be displayed in 
the Time display window .

End of timer: The instrument buzzing 
alarm, the “End" is displayed in the Time 
display window.

When the instrument alarms, press any
key and the instrument goes into 
standby mode.

Power Recovery

If the power supply is cut off suddenly 
while the instrument is in operation, the 
unit will automatically run at the 
previously set parameter upon power  
restoration. The display windows will 
flash. Press any button to stop the 
display window from flashing.

13     Section 5  |  Operation

Digital Cel-Gro Tissue Culture Rotator      14

Содержание 88882015

Страница 1: ...e thermofisher com Find out more at thermofisher com In Canada For customer service call 1 800 234 7437 To fax an order use 1 800 463 2996 To order online thermofisher ca Operating Manual Revision A 04 01 2021 2021 Thermo Fisher Scientific Inc All rightsreserved All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified ...

Страница 2: ...ction 4 Overview Specifications Environmental Conditions Safety Instructions Section 5 Operation Control Panel Installation Accessory Installation Settings Section 6 Safety Tips and Maintenance Section 7 Troubleshooting Section 8 Optional Accessories Section 9 Warranty Information Section 10 Compliance Contents 1 2 3 4 4 5 5 6 6 6 7 8 8 9 9 13 15 16 17 19 20 ...

Страница 3: ...uation if not avoided may result in minor or moderate injury Indicates a hazardous situation which if not avoided may result in minor or moderate injury Do not put heavy things on the power cord Do not put the machine on the cord It may take off the wire coating and cause electric shock or fire Do not touch it with wet hands and place the main plug correctly It could cause the electric shock or in...

Страница 4: ...various volume tissue culture Rotator is designed for the different application such as schools laboratories hospitals Rotator is used for routine blood test and other mixing applications This product is intended to be used in a laboratory setting and is not to be used in a clinical setting Section 3 Inspection and Installation Table 1 Packing List General Power Adaptor US Plug CN Plug EU Plug UK ...

Страница 5: ...Range 95 180 Angle Accuracy 2 Max Load Contain rotator drum weight 5kg Timing Range 0 9999min Overall Dimensions 383 260 412mm Packaging Dimensions 486 381 470mm Net Weight 8 2Kg 18 1lb Gross Weight 10 4Kg 22 9lb Input Requirement 100 240VAC 50 60Hz 8W 0 2A Output Requirement 24V 2 5A Certification RoHS WEEE cCSAus CE Mark Noise Level 55dB with no load Application Environmental Conditions indoor u...

Страница 6: ...erature 0 to 60 Humidity 20 to 90 non condensing Stop the unit immediately and DO NOT operate until clean up is complete and vapors have dissipated DO NOT immerse the unit for cleaning DO NOT operate the unit if it shows signs of electrical or mechanical damage Note The rotary plate may have a little vibration below 11 rpm The vibration will relieve or disappear when more load is added Various ind...

Страница 7: ...s 1 Turn the motor housing back and forth gently by hand and pull the bolt up at the same time Digital Cel Gro Tissue Culture Rotator 10 2 If the bolt still cannot be pulled out please use vise grip plier to pull the bolt up and turn the motor housing at the same time 3 Please contact us immediately if the problem still exists 2 Rotate the motor housing gently by hand to adjust the angle 3 Insert ...

Страница 8: ... is possible for the tray to exhibit uneven or erratic rotation This does not necessarily indicate equipment malfunction and a cause for returning the unit to the manufacturer Loading and Unloading the Tray 1 Insert or remove culture tubes starting from the center to the outside edge of the tray 2 Make sure the weight is distributed evenly on the tray 3 Maintain the overall balance of the tray esp...

Страница 9: ...hown on the Time display window starts flashing turn the knob to increase or decrease the time value Press the knob when the time shown on the Time display window reaches the set value within 5s Speed Settings Press the Speed setting knob When the Speed display window starts flashing turn the knob to increase or decrease the speed value Press the knob when the speed shown on the Speed display wind...

Страница 10: ...ment please shut down the instrument and clean up the liquid immediately If the liquid has already spilled into the unit cut off the power supply first and immediately clean up the liquid at the surface of the instrument Place the instrument in a ventilated and dry environment for 24 hours before reuse If the instrument is not functioning after drying for 24 hours please contact the manufacturer W...

Страница 11: ...Drum 88882155 1 Ø380 78mm 142xØ17mm Rotator Drum 88882154 1 Ø310 115mm 64x18 5mm Rotator Drum Digital Cel Gro Tissue Culture Rotator 18 Description Cat No Max Qty Figure Dimensions General Power Adaptor w US plug 88870127 88870128 88870129 88870126 1 1 1 1 General Power Adaptor w AUS CN plug General Power Adaptor w EU plug General Power Adaptor w UK plug 125VAC 10A 1 8m 250VAC 10A 1 8m 250VAC 16A ...

Страница 12: ...e the USA please contact local Thermo Technical Services Department or local distributor for warranty information Digital Cel Gro Tissue Culture Rotator 20 Section 10 Compliance 1 European Union The European voltage models of this product meet all the applicable requirements of the European Directives and therefore display the CE Marking These Directives are captured in the EU Declaration of Confo...

Страница 13: ...th the requirements of the legislative act Administration on the Control of Pollution Caused by Electronic Information Products ACPEIP A label of conformance such as one of the following may be found on the product 5 End of Life Care Some considerations and suggestions are listed below for proper disposal of this product While addressing these actions for safe recycling and disposal please follow ...

Отзывы: