All installations and services must be performed by qualified personnel.
AIR HANDLER
Each air handler is shipped with an evaporator preinstalled. The AH2435E1 is shipped with a
12U2430AG15 evaporator coil for 2 to 3 ton operation. The AH4260E1is shipped with a 12U3648AG17
evaporator coil for 3 to 5 ton operation.
The construction of the air handler permits easy knockdown and reassembly. See Figure A.
Figure A.
FOLLOW THESE STEPS FOR KNOCKDOWN OF AIR HANDLER:
1. Start with unit setting in a vertical position(Figure A).
2. Remove middle door.
3. Remove screws from bottom door, top door, and top front panel. Remove doors and top panel of air
handler.
4. Remove the retention clip from in front of the A-coil drain pan and the horizontal drain pan shipping
screw(s) from the right side casing.
5. Remove the A-coil assembly.
6. Disconnect power leads and unplug circulation pump connector from the blower control board.