Models 135A and 136S Portable Conductivity Meters

Appendix

41

Warranty

The Thermo Orion warranty covers failures due to manufacturer’s workman-
ship or material defects from the date of purchase by the user. User should re-
turn the warranty card to Thermo Orion and retain proof of purchase. Warranty
is void if product has been abused, misused, or repairs attempted by unautho-
rized persons.
Warranties herein are for product sold/installed by Thermo Orion or its autho-
rized dealers. 
Any product sold by a U.S. or Canadian distributor must be returned to Thermo
Orion for any warranty work. A Return Authorization Number must be obtained
from Thermo Orion’s Laboratory Technical Service before returning any prod-
uct for in-warranty repair or replacement. 
In the event of failure within the warranty period, Thermo Orion will at Thermo
Orion’s option, repair or replace product not conforming to this warranty. There
may be additional charges, including freight, for warranty service performed in
some countries. For service, call Thermo Orion (or its authorized dealer outside
the United States and Canada). Thermo Orion reserves the right to ask for
proof of purchase, such as the original invoice or packing slip.
Laboratory pH Meters, SensorLink

, pH/ISE Meters, PerpHecT

 pH/ISE

Meters, Sage

t

 Pumps, Cahn

 Balances, 930 Ionalyzer

t

, 950 ROSS

t

 FAST

QC

t

 Titrator, 960 Titrator PLUS

, Karl Fischer Titrators, pHuture

t

 Conver-

sion Box, Wine Master

t

, 607 Switchbox, rf link

t

, Vacuum degasser, Flowme-

ter are warranted to be free from defects in material and workmanship for a pe-
riod of twelve (12) months from the date of purchase by the user or eighteen
(18) months from date of shipment from Thermo Orion, whichever is earlier,
provided use is in accordance with the operating limitations and maintenance
procedures in the instruction manual and when not having been subjected to
accident, alteration, misuse, or abuse.
The warranty period for 960 Titrator PLUS, 950 Fast QC Titrator, Wine Master
and 930 Ionalyzer pumps is three (3) months from date of purchase.
ThermaSense

t

 Dataloggers are warranted for a period of twelve (12) months

from date of purchase.
Economy Line Electrodes, Models 91-05, 91-06, 91-15, 91-16, 91-25, 91-26,
91-35, 91-36 and 92-06, are warranted to be free from defects in material and
workmanship for a period of three (3) months from date of purchase by cus-
tomer or six (6) months from date of shipment from Thermo Orion, whichever is
earlier. Warranty also includes failure for any reason (excluding breakage), ex-
cept abuse, provided the electrode is not used in solutions containing silver,
sulfide, perchlorate, or hydrofluoric acid; or in solutions more than one (1) molar
in strong acid or base at temperatures above 50

°

C.

Ion Selective Electrodes, ionplus

 Electrodes, ROSS Electrodes, Sure-Flow

Содержание 135A

Страница 1: ...Instruction Manual Models 135A and 136S Waterproof and Intrinsically Safe Portable Conductivity Meters...

Страница 2: ...Access and Wine Master are trademarks of Thermo Orion Guaranteed Success and The Technical Edge are service marks of Thermo Orion PerpHecT meters are protected by U S patent 4 321 544 Other patents pe...

Страница 3: ...tatic charges For example never wipe off the meter with a dry cloth Observe the relevant regulations concern ing ESD Whenever it is likely that the protection has been impaired the meter shall be made...

Страница 4: ...t is used to represent keys e g cal Display examples or keys whose functions are explained are frequently shown in the left hand column Notes provide important information which should always be obser...

Страница 5: ...ters 1 2 Operation 3 Meter Design 3 Display 4 Keypad 4 Connection and Start up 6 Configuration 8 Calibration 11 Measurement 15 Data Log Memory 17 Data Log 18 Clock Mode 20 Serial Interface 21 Standard...

Страница 6: ...I Appendix 29 Declarations of Conformity 29 Certificate of Conformity 31 Control Drawing 33 Ordering Information 35 Specifications 39 Specifications for PRT300 Printer 40 Warranty 41 Technical Terms 4...

Страница 7: ...k strap This instruction manual Quickstart instructions Interface cable with adapter for printer and PC PC software Short Description of Meters The Models 135A and 136S measure conductivity sali nity...

Страница 8: ...re date and time Recording takes place either manually interval or event controlled To minimize battery consumption the meter switches off after either one or twelve hours when it is not operated Only...

Страница 9: ...e Conductivity Meters Operation 3 2 Operation Meter Design 1 2 3 4 5 1 Sensor connection 2 3 Separate temperature probe connection 4 PC printer interface connection 5 Probe holder removable meas cal S...

Страница 10: ...ching on the meter automatically performs a self test and checks for the presence of a temperature probe Then it goes into the measuring mode Pressing the meas key returns the meter to the measur ing...

Страница 11: ...values Pressing the RCL key activates the data logger for reading measured values Pressing the print key sends the currently measured value to a printer or PC Pressing the RCL and print keys prints o...

Страница 12: ...ith integrated temperature probe 3 meter cable K 0 55 cm 013660 4 electrode epoxy graphite sensor with integrated temperature probe 20 meter cable K 0 55 cm Connection Socket Sensor 1 Separate tempera...

Страница 13: ...the contents of the data log remain permanently stored both with the meter switched off and with the batteries removed battery re placement Pressing the power key switches the meter into measur ing mo...

Страница 14: ...time format 24 hours and day month year or 12 hours a m p m and month day year To activate the configuration hold down the cal key with the meter switched off and then press the power key The menu it...

Страница 15: ...compensated conductivity of another known calibration solution To protect the batteries the meter switches off automati cally when not operated for a longer time than specified You can select whether...

Страница 16: ...eration 10 The temperature can be displayed either in C or F Default setting C You can choose between the display format 24 hours and day month year and the format 12 hours a m p m and month day year...

Страница 17: ...should be rinsed off with distilled water Afterwards the sensor should be wiped dry and rinsed with the calibration solution to be used The cell constant is determined by the size and geometric arran...

Страница 18: ...y to activate calibration The cell constant determined or set during the last calibration is displayed Pressing the meas key exits calibration again Set the cell constant of the sensor used with the Y...

Страница 19: ...ble to choose from Con firm the corresponding solution with the cal key Immerse the clean and dry sensor in the calibration solu tion also see Clean sensors Pg 11 Press the cal key to start calibratio...

Страница 20: ...calibration is not desired cancel the process with the meas key During calibration the lower line indicates the temperature The automatic drift check checks the stability of conductiv ity and temperat...

Страница 21: ...erature The instrument offers various temperature compensation methods With the meas key and the Y or B key the temperature compensation method can be selected and set tc OFF No temperature compensati...

Страница 22: ...ctivity TDS comparable to the evaporation residue in mg l the sec ondary display shows the temperature Pressing the meas key and then the Y or B key sets the TDS factor within the range 0 40 1 00 The...

Страница 23: ...store the measured value in the selected memory location After storing the memory loca tion number is automatically incremented and the meter returns to measuring mode Pressing the RCL key displays th...

Страница 24: ...Y or B keys Pressing the STO key confirms the selected mode In the Continue and Start mode this also activates the data log The current data memory location is shown on the display If Clear has been...

Страница 25: ...determine when the value had changed The differen tial value is entered in the subsequent parameter setting step The differential value is always based on the currently set measured variable conducti...

Страница 26: ...he date the clock mode must be acti vated Press the clock and STO keys simultaneously to set the clock The time display flashes Now the time can be set using the Y and B keys Press the STO key again t...

Страница 27: ...meter can be completely remote controlled and all data and parameters can be read Using the printer e g PRT 300 printer you can di rectly print measured values data points and GLPdoct report The RS 2...

Страница 28: ...D TXD DTR GND DSR RTS CTS RI Connection assignment 1 9 Standard Setting for PRT300 Printer Parameter Setting Baud rate 1200 Printer On Configuring the PRT300 Printer In the meter set the baud rate to...

Страница 29: ...ess the RCL and then print keys to print out the logged data All stored data points are printed out with tempera ture date and memory location number Sxx If you only want to print individual data poin...

Страница 30: ...s Sensor defective Break in sensor cable Wrong sensor connected Wrong cell constant entered The measured temperature is outside the ranges Conductivity 20 C to 120 C nLF 0 C to 120 C Salinity 0 C to 3...

Страница 31: ...nsor not immersed far enough in calibration solution The calibration was cancelled after approx 2 minutes because the drift was too large This message only appears briefly during calibration Possible...

Страница 32: ...rity bit Error during the meter self test sequence Possible causes Configuration or calibration data are defective Completely reconfigure and recalibrate the meter Error in the factory settings or sys...

Страница 33: ...atteries To replace the batteries you need 3 alkaline AA cells and a screwdriver Close the protective cover and remove the probe holder Unscrew the four screws on the back of the meter and remove the...

Страница 34: ...th the RCL key and the Y or B key before restarting the data log If you want to store the meter for a longer time the batter ies must always be removed beforehand Leaky batteries may damage the meter...

Страница 35: ...Models 135A and 136S Portable Conductivity Meters Appendix 29 Appendix Declarations of Conformity...

Страница 36: ...Appendix 30...

Страница 37: ...Models 135A and 136S Portable Conductivity Meters Appendix 31 Certificate of Conformity...

Страница 38: ...Appendix 32...

Страница 39: ...Models 135A and 136S Portable Conductivity Meters Appendix 33 Control Drawing...

Страница 40: ...Appendix 34...

Страница 41: ...proof Intrinsically Safe Conductivity Meter Probe and Field Kit 0135A0 Model 135A Advanced Waterproof Conductivity Meter and Probe 0135A2 Model 135A Advanced Waterproof Conductivity Meter Only 0135A3...

Страница 42: ...S0 Model 266S Advanced Waterproof In trinsically Safe pH Meter and Electrode 0266S2 Model 266S Advanced Waterproof In trinsically Safe pH Meter Only 0266S3 Model 266S Advanced Waterproof In trinsicall...

Страница 43: ...y standard 12 9 mS 0 1 KCl 5 x 60 mL 011007 Conductivity standard 1413 mS 0 01 KCl 5 x 60 mL 011008 Conductivity standard 100 mS 5 x 60 mL 026AKT Field Case for Thermo Orion Water proof Meters 013650...

Страница 44: ...Appendix 38 Thermo Orion Description Cat No PRT300 Ink based Printer 110 V Cable Included PRT301 Ink based Printer 220 V Cable Included PRT302 Replacement Printer Ribbon 1 each...

Страница 45: ...for separate temperature probe Permissible cell constant 0 010 to 199 9 cm 1 adjustable Sensor standardization Direct entry of the cell constants Automatic determination of the cell constants with Th...

Страница 46: ...No Ex 97 D 2118 FM approved Ambient temperature Operation 10 to 55 C Transport and storage 20 to 70 C Power supply 3 alkaline AA batteries Operating time Approx 1 000 h clock operation 2 years Enclos...

Страница 47: ...s Cahn Balances 930 Ionalyzert 950 ROSSt FAST QCt Titrator 960 Titrator PLUS Karl Fischer Titrators pHuturet Conver sion Box Wine Mastert 607 Switchbox rf linkt Vacuum degasser Flowme ter are warrante...

Страница 48: ...and maintenance procedure in the instruction manual and when not having been subjected to accident alteration misuse or abuse Series 100 Conductivity Meters Models 105 115 125 145 and 150 Series 100...

Страница 49: ...R IM PLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING OR USAGE OF TRADE THE BUYER S...

Страница 50: ...calibrating a conductivity meter The data log records up to 100 measured values together with the temperature date and time Logging takes place either interval or event controlled measured value diff...

Страница 51: ...from the start of a calibration step to the stabilization of the measured value The salinity indicates the salt content particularly of sea waters as a cumulative parameter It is specified in parts pe...

Страница 52: ...ion menu 8 Connecting interface 22 Connection interface 6 sensor 6 separate temperature probe 6 Connection assignment 6 Control Drawing 33 D Data log 18 definition 44 setting 18 19 Data log memory 17...

Страница 53: ...ng information 35 P Package contents 1 Printer PRT300 configuration 22 specifications 40 standard settings 22 Printing GLPdoc reports 23 measured values 23 R Response time description 45 RS 232 interf...

Страница 54: ...Index 48 Time format configuring 10 W Warranty 41...

Страница 55: ......

Страница 56: ...Tel 44 1353 666111 Fax 44 1353 666011 Thermo Orion Far East Room 904 Federal Building 369 Lockhart Road Wanchai Hong Kong Tel 852 28360981 Fax 852 28345160 Thermo Orion India 105 1st Floor Ashoka Apa...

Отзывы: