Operating Instructions for Standard HMI Control Panel
45
•
A flashing Pretrip LED indicates that the
Pretrip Test is being initialized. When the
Pretrip Test starts, the Pretrip LED will glow
steady amber to indicate the test is in progress.
The display will show the Standard Display.
•
The Pretrip Test will take about 20 - 25
minutes, depending on conditions.
IMPORTANT: The box temperature will vary
during the Pretrip Test. This is normal
operation.
When the Pretrip Test is complete or if a
Shutdown Alarm occurs, the amber Pretrip LED
will turn off.
Stopping a Pretrip Test:
To stop a Pretrip Test at
any time, press the POWER OFF Key to turn the
unit off. This will generate Alarm Code 28 Pretrip
Abort. Other alarm codes may also be generated.
This is normal when the Pretrip Test is halted
before completion.
Pretrip Test Results
Pass Pretrip Test
•
If the unit passes the Pretrip Test, the amber
Pretrip Test LED will turn off at the
completion of the test and the unit will
continue to run as required. This signifies that
the unit passed the Pretrip Test.
Fail Pretrip Test with Check Alarms
•
If the unit fails the Pretrip Test with Check
alarms, the Alarm Icon will appear when the
alarm condition occurs. The Pretrip Test will
continue to run unless a Shutdown Alarm
occurs.
•
The amber Pretrip Test LED will turn off at
the completion of the test, but the Alarm Icon
will remain lit. This indicates that one or more
Check Alarm conditions occurred during the
Pretrip Test. More than one alarm may be
present.
•
View and record the alarm(s), correct as
necessary, clear the alarm(s) and repeat the
Pretrip Test.
Fail Pretrip Test with Shutdown Alarms
•
If the unit fails the Pretrip Test with a
Shutdown alarm, the Alarm Icon will appear
when the alarm condition occurs, the unit will
immediately shut down and the amber Pretrip
Test LED will turn off.
•
The Pretrip Test will be aborted.
•
Alarm Code 28 Pretrip Abort will be set along
with the Shutdown Alarm that was detected.
This signifies that a Shutdown Alarm occurred
during the Pretrip Test and that the test was
aborted. Other alarms may also be present.
•
View and record the alarm(s), correct as
necessary, clear the alarm(s) and repeat the
Pretrip Test.
Display Brightness
The brightness of the SR-3 Standard Truck HMI
Control Panel display can be adjusted to allow for
changing ambient light conditions. The choices
available to the operator are HIGH, MEDIUM
and LOW.
To change the display brightness press and hold
the ON key then press the UP ARROW Key to
increase display brightness and the DOWN
ARROW Key to decrease display brightness.
Figure 37: ON Key, UP/DOWN Arrow Keys
Содержание T-1080S
Страница 102: ...Engine Maintenance 101 Figure 182 Fuel and Oil System Components ...
Страница 182: ...Index 181 Unit Options 23 W wiring 79 wiring diagrams index 182 ...
Страница 184: ...183 Schematic Diagram Page 1 of 2 RELEASED 06 Jul 2015 13 52 47 GMT 7 ...
Страница 185: ...184 Schematic Diagram Page 2 of 2 RELEASED 06 Jul 2015 13 52 47 GMT 7 ...
Страница 186: ...185 Wiring Diagram Page 1 of 5 ...
Страница 187: ...186 Wiring Diagram Page 2 of 5 RELEASED 06 Jul 2015 13 52 47 GMT ...
Страница 188: ...187 Wiring Diagram Page 3 of 5 ...
Страница 189: ...188 Wiring Diagram Page 4 of 5 RELEASED 06 Jul 2015 13 52 47 GMT ...
Страница 190: ...189 Wiring Diagram Page 5 of 5 ...