Unit Description
32
Heat/Defrost Mode
The refrigerant flow in Heat/Defrost Mode is a
conventional hot gas heat cycle. The CIS is closed
and the HGS is open so high pressure refrigerant
vapor leaves the compressor and flows through
the DPR (which maintains a minimum discharge
pressure) and the HGS to the hot has line. Most of
the refrigerant flows through the hot gas line and
the drain pan heater to the evaporator. There, the
refrigerant heats the evaporator and returns to the
compressor through the heat exchanger,
accumulator, and ETV. Some of the refrigerant
flows through the receiver tank pressure check
valve and forces any liquid refrigerant out of
receiver tank through the drier, heat exchanger,
and expansion valve to the evaporator. From
which it returns to the compressor through the
heat exchanger, accumulator, and ETV.
Solenoid and Check Valves
1. Condenser Inlet Solenoid (CIS)-Closed/
Energized
2. Liquid Injection Solenoid (LIS)-Closed/
De-energized but the microprocessor will
open it if necessary to control compressor
temperature.
3. Condenser Check Valve-Closed
4. Receiver Tank Pressure Check Valve-Open
5. Purge Valve (PV)-Open/Energized
6. Purge Check Valve-Closed
7. Hot Gas Solenoid (HGS)-Open/Energized
Figure 9: Heat/Defrost Mode
1
2
3
4
5
6
7
Содержание T-1080S
Страница 102: ...Engine Maintenance 101 Figure 182 Fuel and Oil System Components ...
Страница 182: ...Index 181 Unit Options 23 W wiring 79 wiring diagrams index 182 ...
Страница 184: ...183 Schematic Diagram Page 1 of 2 RELEASED 06 Jul 2015 13 52 47 GMT 7 ...
Страница 185: ...184 Schematic Diagram Page 2 of 2 RELEASED 06 Jul 2015 13 52 47 GMT 7 ...
Страница 186: ...185 Wiring Diagram Page 1 of 5 ...
Страница 187: ...186 Wiring Diagram Page 2 of 5 RELEASED 06 Jul 2015 13 52 47 GMT ...
Страница 188: ...187 Wiring Diagram Page 3 of 5 ...
Страница 189: ...188 Wiring Diagram Page 4 of 5 RELEASED 06 Jul 2015 13 52 47 GMT ...
Страница 190: ...189 Wiring Diagram Page 5 of 5 ...