Unit Description
30
Cool Mode
The refrigerant flow in Cool Mode is a
conventional refrigeration cycle. High pressure
refrigerant vapor leaves the compressor and flows
through the open CIS to the condenser where the
refrigerant releases heat and condenses into high
pressure liquid. The liquid refrigerant flows
through the condenser check valve, receiver tank,
drier, heat exchanger, and the expansion valve
into the evaporator. There, liquid refrigerant
absorbs heat as it evaporates into low pressure
vapor. The refrigerant returns to the compressor
through the heat exchanger, accumulator, and
ETV.
Solenoid and Check Valves
1. Condenser Inlet Solenoid (CIS)-Open/
De-energized
2. Liquid Injection Solenoid (LIS)-Closed/
De-energized but the microprocessor will
open it if necessary to control compressor
temperature.
3. Condenser Check Valve-Open
4. Receiver Tank Pressure Check Valve-Closed
5. Purge Valve (PV)-Closed/De-energized
6. Purge Check Valve-Closed
7. Hot Gas Solenoid (HGS)-Closed/
De-energized
Figure 7: Cool Mode
1
2
3
4
5
6
7
Содержание T-1080S
Страница 102: ...Engine Maintenance 101 Figure 182 Fuel and Oil System Components ...
Страница 182: ...Index 181 Unit Options 23 W wiring 79 wiring diagrams index 182 ...
Страница 184: ...183 Schematic Diagram Page 1 of 2 RELEASED 06 Jul 2015 13 52 47 GMT 7 ...
Страница 185: ...184 Schematic Diagram Page 2 of 2 RELEASED 06 Jul 2015 13 52 47 GMT 7 ...
Страница 186: ...185 Wiring Diagram Page 1 of 5 ...
Страница 187: ...186 Wiring Diagram Page 2 of 5 RELEASED 06 Jul 2015 13 52 47 GMT ...
Страница 188: ...187 Wiring Diagram Page 3 of 5 ...
Страница 189: ...188 Wiring Diagram Page 4 of 5 RELEASED 06 Jul 2015 13 52 47 GMT ...
Страница 190: ...189 Wiring Diagram Page 5 of 5 ...