background image

Simple to View:

Cause of Alarm

1. Return to the Standard Display 
Screen. 

2. Press the MENU Key. 

3. Press the UP or DOWN Key until 
the Alarm Menu appears. 

4. Press the SELECT Key. 
The Alarm Display will appear.

5. If alarms are present, the quantity 
of alarms and the most recent alarm 
code number will be shown.

6. If necessary to view all alarms, 
scroll down using the DOWN Key.

7. If a serious condition occurs, the 
unit will be shut down to prevent 
damage to the unit or the load. If 
this occurs, the Alarm Icon will 
appear, the display and backlight 
will flash on and off. 

NOTE: For more detailed infor-

mation, see the Operation chapter in the appropriate unit operating 
manual.

Simple to View:

Clearing Alarm Codes

1.If the alarm situation has been 
resolved press the CLEAR Key to 
clear the alarm.

2. The display will briefly show 
CLEARING ALARMS – PLEASE 
WAIT. Then the Alarm Menu will 
reappear.

3. Press the HELP Key for 
additional information regarding the 
alarm shown on the display. Also 
see the complete Alarm Code list in 
the next column.

4. To return to the Main Menu press 
the EXIT Key. To return to the 
Standard Display press the EXIT 
Key again.

NOTE: For more detailed information, see the Operation chapter in the 
appropriate unit operating manual.

 

MENU

35

35

SET

SENSORS

GAUGES

POINT

ON

OFF

2

1

 

MENU

35

35

SET

SENSORS

GAUGES

POINT

ON

OFF

1 OF 2 ALARMS

DOWN

EXIT

CLEAR

HELP

5

64

x

PRETRIP REMINDER

64

CHECK AMBIENT TEMP SENSOR

ON

OFF

 

ON

OFF

MAIN MENU

DOWN

EXIT

SELECT

UP

PRETRIP
LANGUAGE
ALARMS
GAUGES

7

4

3

5

6

 

ON

OFF

1 OF 1 ALARMS

DOWN

EXIT

CLEAR

HELP

66

x

64

LOW ENGINE OIL LEVEL

1 OF 2 ALARMS

DOWN

EXIT

CLEAR

HELP

5

64

x

PRETRIP REMINDER

64

CHECK AMBIENT TEMP SENSOR

ON

OFF

1

3

Simple to 

Determine:

Cause of Alarm

0

No  Alarms  Exist

2

Evaporator Coil Sensor

3

Control Return Air Sensor

4

Control Discharge Air Sensor

5

Ambient Air Sensor

6

Coolant Temp Sensor

7

Engine RPM Sensor

9

High Evaporator Temperature

10

High Discharge Pressure

11

Unit Controlling on Alternate Sensor

12

Sensor or Digital Input Shutdown

13

Sensor Calibration Check

17

Engine Failed to Crank

18

High Engine Coolant Temperature

19

Low Engine Oil Pressure

20

Engine Failed to Start

21

Cooling Cycle Check

22

Heating Cycle Check

23

Cooling Cycle Fault

24

Heating Cycle Fault

25

Alternator Check

26

Refrigeration Capacity 

28

Pretrip Abort

29

Defrost Damper Circuit 

30

Defrost Damper Stuck

31

Oil Pressure Switch

32

Refrigeration Capacity Low

33

Check Engine RPM

35

Run Relay Circuit

36

Electric Motor Failed to Run

37

Engine Coolant Level

38

Electric Phase Reversed 

39

Water Valve Circuit

40

High Speed Circuit

41

Check Engine Coolant Temperature

42

Unit Forced to Low Speed

43

Unit Forced to Low Speed Modulation

44

Check Fuel System

45

Hot Gas Bypass or Hot Gas Bypass 

         Circuit
46

Check Air Flow

48

Check Belts/Clutch

50

Reset Clock

52

Heat Circuit

54

Test Mode Time-out

56

Host Evap Fan Low Speed

57

Host Evap Fan High Speed

61

Low Battery Voltage

62

Ammeter Out of Calibration

63

Engine Stopped

64

Pretrip Reminder

65

Abnormal Temperature Differential

66

Low Engine Oil Level

67

Liquid Line Solenoid Circuit

68

Internal Controller Fault

70

Hourmeter Failure

74

Controller Reset to Defaults

79

Internal Data Logger Overflow

80

Compressor Temp Sensor

81

High Compressor Temp

82

High Compressor Temperature Shutdown

83

Low Engine Coolant Temperature

84

Restart Null

85

Forced Unit Operation

86

Discharge Pressure Sensor

87

Suction Pressure Sensor

89

Check Electronic Throttling Valve Circuit

90

Electric Overload

91

Electric Ready Input

92

Sensor Grades Not Set

93

Low Compressor Suction Pressure

96

Low Fuel Level

98

Fuel Level Sensor

99

High Compressor Pressure Ratio

105 Receiver Tank Pressure Solenoid Circuit
106 Purge Valve Circuit
107 Condenser Inlet Solenoid Circuit
108 Door Open Time-out
110 Suction Line Solenoid Circuit
111 Unit Not Configured Correctly
113 Electric Heat Circuit
114 Multiple Alarms - Cannot Run
117 Auto switch from Diesel to Electric
118 Auto switch from Electric to Diesel
120 Alternator Exciter Circuit
121 Liquid Injection Circuit
122 Diesel/Electric Relay Circuit
127 Setpoint Not Entered
128 Engine Run Time Maintenance Reminder #1
129 Engine Run Time Maintenance Reminder #2
130 Electric Run Time Maintenance Reminder #1
131 Electric Run Time Maintenance Reminder #2
132 Total Unit Run Time Maintenance Reminder #1
133 Total Unit Run Time Maintenance Reminder #2
134 Controller Power On Hours
141 Autoswitch Diesel to Electric Disabled
143 Remote Zone Drain Hose Heater Output
144 Lost Expansion Module CAN Communication
145 Loss of Controller "On" Feedback Signal
146 Software Version Mismatch
148 Autoswitch Electric to Diesel Disabled
149 Alarm Not Identified
150 Out of Range Low
151 Out of Range High
153 Expansion Module Flash Load Failure
157 OptiSet Plus Mismatch
158 Primary Software Failed to Load
203 Display Return Air Sensor
204 Display Discharge Air Sensor
252  Check Fresh Air Exchange Circuit
500 Host Evaporator Fan Low Speed
501 Host Evaporator Fan High Speed
502 Host Evaporator Fan RPM Sensor
503 Host Condenser Fan 1 RPM Sensor
504 Host Condenser Fan 2 RPM Sensor
505 Roadside Condenser Fan Motor Speed Circuit
506 Curbside Condenser Fan Motor Speed Circuit
507 Digital Scroll Output Circuit
508 Speed Request Communication Error
509 Engine Control Unit (ECU) Failed to Enable
510 Engine Control Unit (ECU) Run Signal Failed
511 Engine Wait to Start Time Delay Expired
512 High Compressor Suction Pressure
513 Low Compressor Suction Ratio
514 Minimum ETV Discharge Superheat 
         Temperature
515 Minimum ETV Discharge Superheat 
         Temperature
516 I/O Controller to Application Controller 
         Communication Failure
517 Check for Water in Fuel System
518 Generator Ground Fault
519 Check Battery Charger Input Power
520 Check Battery Charger Output Power
521 Battery Charger External/Environmental Fault 

SR-4 

Smart Reefer™ 4 

Microprocessor

Driver Guide to 

Simple 

Operation

TK 55771-2-PC (Rev. 0, 01/14)                    ©Thermo King Corporation

522 Battery Temperature Sensor Alarm
523 Battery Temperature Sensor Alarm
524 Generator Operational Limit V out to 
          Frequency Ratio
525 Generator Frequency Range Fault
526 Generator Operational Limit Output Current
527 Reserved
528 Controller Not Receiving Messages From 
          Battery Charger
529 Check Fuel Pump Circuit
530 Low Pressure Differential
531 Check Economizer Pressure Sensor
538 Engine J1939 CAN Datalink Degraded
539 Engine J1939 CAN Datalink Failed
599 Engine Service Tool Connected
600 Check Crankshaft Speed Sensor
601 Check Camshaft Speed Sensor
602 Check Intake Throttle Position Sensor
603 Check Exhaust Pressure Sensor
604 Check Coolant Temperature Sensor
605 Check Fresh Air Temperature Sensor 
606 Reserved
607 Check Fuel Temperature Sensor
608 Check Rail Pressure Sensor
609 Check Intake Pressure Sensor
610 Check Atmospheric Pressure Sensor
611

Check Glow Plug Circuit

612 Check Intake Throttle Circuit
613 Check Injector(s)
614 Check High Pressure Fuel Pump
615 Rail Pressure Fault
616 Engine Overspeed
617 Internal ECU Fault
618 Check EGR System
619 ECU Main Relay Fault
620 Reserved
621 Reserved
622 Reserved
623 TRU CAN Message Timeout
624 Check Intake Air Temperature Sensor
625 Check Intake Air Temperature Sensor
626 Check Exhaust Temperature Sensor
699 Unknown ECU Fault

Отзывы: