Simple to Start:
1. Press the ON Key.
2. The THERMO KING Logo appears
briefly.
3. The startup screen appears while
communications are established and
the unit prepares for operation.
4. The Standard Display defaults to the “TemperatureWatch” screen after
2-1/2 minutes. The TemperatureWatch Display will remain on until any key
is pressed or a check, prevent or shutdown alarm occurs.
NOTE: For more detailed information, see the Operation chapter in
the appropriate unit operating manual.
Simple to Set:
CYCLE-SENTRY or Continuous Mode
1. Return to the Standard Display.
2. Press the CYCLE-SENTRY/
Continuous Key.
3. The “Programming Continuous
Mode” or “Programming CYCLE-
SENTRY Mode” screen briefly
appears.
4. The “New System Mode is
Continuous” screen or the “New
System Mode CYCLE-SENTRY”
screen briefly appears.
5. The Standard Display appears
and the heading on top of screen
reads the new mode.
6. Pressing the CYCLE-SENTRY/Continuous Key again will change the
unit back to the previous mode.
NOTE: For more detailed information, see the Operation chapter in
the appropriate unit operating manual.
ON
OFF
1
ON
OFF
CONFIGURING SYSTEM
PLEASE WAIT
3
ON
OFF
MENU
35
°F
35
SET
SENSORS
GAUGES
POINT
.8
1
2 & 6
ON
OFF
NEW SYSTEM MODE IS
CONTINUOUS
ON
OFF
PROGRAMMING CONT MODE
PLEASE WAIT
3
5
Simple to Set:
Setpoint Temperature
1. Press any key to return to the
Standard Display.
2. Press the SETPOINT Key on
the Standard Display.
3. Press the + or - Keys to change
the setpoint reading.
4. Press the YES or NO Key
accordingly.
5. The Standard Display appears
with setpoint changed to the new
setpoint.
NOTE: For more detailed
information, see the Operation
chapter in the appropriate unit
operating manual.
Simple to Check:
Gauges
1. Return to the Standard Display.
Press the MENUKey.
2. Use UP and DOWN soft keys
to scroll to the gauges option.
Press the SELECT Key when
gauges option is highlighted.
3. Press BACK or NEXT Keys to
scroll through following gauges: Coolant Temperature, Coolant Level,
Engine Oil Pressure, Engine Oil Level, Amps, Battery Voltage, Accessory
Battery Voltage, Engine RPM, Fuel Level Sensor, Discharge Pressure,
Suction Pressure, ETV Position, Fresh Air Exchange, I/O. If no keys are
pressed within 30 seconds, the screen will return to the Standard Display.
4. Press the LOCK Key to display any gauge screen for an indefinite
period. Press the key again to unlock the screen.
5. Press the EXIT Key to return to the Standard Display.
NOTE: For more detailed information, see the Operation chapter in
the appropriate unit operating manual.
MENU
35
°F
35
PRODUCT/
SENSORS
GAUGES
SETPOINT
.8
ON
OFF
2
ON
OFF
NEW SETPOINT IS
40 F
-
NO
NEW SETPOINT WILL BE
40 F
+
+/- TO CHANGE
OK?
YES
ON
OFF
ON
OFF
-
NO
NEW SETPOINT WILL BE
40 F
+
+/- TO CHANGE
OK?
YES
4
3
5
ON
OFF
MENU
35
°F
35
SET
SENSORS
GAUGES
POINT
.8
1
2
ON
OFF
BATTERY VOLTAGE
13.
8
NEXT
EXIT
LOCK
BACK
v
3
Simple to Defrost:
Initiate Manual Defrost
1. Return to the Standard Display.
2. Press the DEFROST Key.
3. The display will show
“Programming Defrost Please
Wait.”
4. The display then shows the
Defrost Display. The bar indicator
will fill in showing the time
remaining to complete the Defrost
cycle. When the Defrost cycle is
complete the display returns to
Standard Display screen.
NOTE: For more detailed information, see the Operation chapter in
the appropriate unit operating manual.
Simple to Access:
Sensors
1. Return to the Standard
Display.
2. Press the SENSORS Key.
3. Press the BACK or NEXT
Keys to scroll through the
following sensor screens:
Control Return Air
Temperature, Display Return Air
Temperature, Control Discharge Air Temperature, Display Discharge Air
Temperature, Temperature Differential, Evaporator Coil Temperature,
Ambient Air Temperature, Spare 1 Temperature, Datalogger Temperature
Sensors 1-6 and the Board Temperature Sensor. If no keys are pressed
within 30 seconds, the screen will return to the Standard Display.
4. Press the LOCK Key to display any sensor screen for an indefinite
period. Press the key again to unlock the screen.
5. Press the EXIT Key to return to the Standard Display.
NOTE: For more detailed information, see the Operation chapter in
the appropriate unit operating manual.
ON
OFF
MENU
35
°F
35
SET
SENSORS
GAUGES
POINT
.8
2
DEFROST STARTED
ON
OFF
3
35
MENU
SET
SENSORS
GAUGES
POINT
ON
OFF
4
ON
OFF
MENU
35
°F
35
SET
SENSORS
GAUGES
POINT
.8
2
1
CONTROL DISCHARGE AIR TEMPERATURE
48.
NEXT
EXIT
LOCK
3
°F
BACK
ON
OFF
3
Simple to Check:
Pretrip Test
1. Clear all alarm codes.
2. Return to the Standard Display.
3. Press the MENU Key.
4. Press the UP or DOWN Key as to
choose the Pretrip Menu.
5. Press the SELECT Key to start a
Pretrip Test.
6. If the unit is not running, a Full
Pretrip will be initiated. If the unit is
running in either diesel or electric
mode, a Running Pretrip will be
performed.
7. When all tests are complete, the results are reported as PASS, CHECK or
FAIL. If the results are CHECK or FAIL, the accompanying alarm codes will
direct the technician to the cause of the problem.
NOTE: For more detailed information, see the Operation chapter in the
appropriate unit operating manual.
Simple to Check:
Hourmeters
1. Return to the Standard Display
screen.
2. Press the MENU Key.
3. Scroll through Main Menu by
repeatedly pressing the UP and
DOWN Keys until the hourmeters
Main Menu Screen appears.
4. Press the SELECT Key to enter the Hourmeters Menu.
5. Press the NEXT and BACK Keys to view the Hourmeter Displays.
NOTE: For more detailed information, see the Operation chapter in the
appropriate unit operating manual.
MENU
35
°F
35
SET
SENSORS
GAUGES
POINT
.8
ON
OFF
3
2
ON
OFF
MAIN MENU
DOWN
EXIT
SELECT
UP
PRETRIP
LANGUAGE
ALARMS
GAUGES
4
4
5
EXIT
PRETRIP
PASS
ON
OFF
7
MENU
35
°F
35
SET
SENSORS
GAUGES
POINT
.8
ON
OFF
2
1
ON
OFF
MAIN MENU
DOWN
EXIT
SELECT
UP
SENSORS
DATA LOGGER
HOURMETERS
MODE
4