Operating Instructions
96
shutdown alarm that is preventing diesel mode operation. If the
unit is switched back to diesel mode, the alarm again become a
diesel mode shutdown alarm and prevents unit operation.
In the same manner, if a shutdown alarm occurs that affects
only electric mode operation and the unit is switched to diesel,
the electric mode shutdown alarm becomes a diesel mode log
alarm to allow diesel mode operation. If the unit is switched
back to electric mode, the alarm reverts to an electric mode
shutdown alarm and prevents unit operation. If the unit is
configured for electric to diesel Auto-Switch, it automatically
starts and runs in diesel mode if an electric shutdown occurs.
Clearing Alarm Codes
Most alarm codes can be cleared conventionally from the
Alarm Menu using the CLEAR Key.
The following control and display sensor alarm codes can only
be cleared from the Maintenance Menu or Guarded Access
Menu:
•
Alarm Code 03 Check Control Return Air Sensor
•
Alarm Code 04 Check Control Discharge Air Sensor
•
Alarm Code 203 Check Display Return Air Sensor
•
Alarm Code 204 Check Display Discharge Air Sensor
The following alarm codes clear automatically:
•
Alarm Code 64 Pretrip Reminder - Clears when a Pretrip
Test is performed.
•
Alarm Code 84 Restart Null - Clears when the unit is no
longer in a restart null due to a Prevent Alarm.
•
Alarm Code 85 Forced Unit Operation - Clears when the
unit is no longer running in a forced mode due to a Prevent
Alarm.
•
Alarm Code 91 Check Electric Ready Input - Clears
automatically when the unit starts running.
•
Alarm Code 92 Sensor Grades Not Set - Clears when the
sensor grade is changed from 5H.
If the Limited Alarm Restarts feature is enabled the following
additional alarm codes may only be cleared from the Guarded
Access Menu. If this is the case, the CLEAR soft key will not
appear if the alarms are displayed from the Main Menu or the
Maintenance Menu.
•
Alarm Code 10 High Discharge Pressure
•
Alarm Code 23 Cooling Cycle Fault
Содержание Precedent S-600
Страница 9: ...6 ...
Страница 11: ...Introduction 8 ...
Страница 15: ...EPA Emission Control System Warranty Statement 12 ...
Страница 23: ...Safety Precautions 20 Do Not Use Ether Starting Aids Figure 6 Do Not Use Ether Starting Aids Near Engine ...
Страница 38: ...Unit Description 35 Figure 13 SR 4 Controller ...
Страница 39: ...Unit Description 36 ...
Страница 43: ...Remote Status Display Optional 40 ...
Страница 127: ...Operating Instructions 124 ...
Страница 143: ...Optional Rear Remote Control Panel 140 ...
Страница 179: ...Alarm Codes 176 ...
Страница 197: ...Warranty 194 ...
Страница 209: ...Maintenance Inspection Schedule 206 ...
Страница 211: ...Serial Number Locations 208 Figure 190 Engine Serial Number Location Figure 191 Unit Serial Number Plate Locations ...
Страница 213: ...Serial Number Locations 210 ...
Страница 216: ...213 CALIFORNIA Proposition 65 Warning Diesel exhaust is a chemical known to the State of California to cause cancer ...
Страница 217: ...214 ...