Operating Instructions
56
NOTE: See detailed Alarm Code list complete
with corrective actions in the Diagnosing and
Troubleshooting Section in the back of the
manual.
Alarm List
Alarm
Code
Type
Description
00
Check
Supply Air Sensor Open Circuit
01
Check
Check Supply Air Sensor Short
Circuit
02
Check
Check Return Air Sensor Open
Circuit
03
Check
Check Return Air Sensor Short
Circuit
04
Check
Check Evaporator Coil Open
Circuit
05
Check
Check Evaporator Coil Sensor
Short Circuit
06
Check
Check Compressor Current Too
High
07
Check
Check Compressor Current Too
Low
10
Check
Check Heater Current Too High
11
Check
Check Heater Current Too Low
12
Check
Check Evaporator Fan High
Speed Current Too High
13
Check
Check Evaporator Fan High
Speed Current Too Low
14
Check
Check Evaporator Fan Low
Speed Current Too High
15
Check
Check Evaporator Fan Low
Speed Current Too Low
16
Check
Check Condenser Fan Current
Too High
17
Check
Check Condenser Fan Current
Too Low
18
Check
Log Power Supply Phase Error
19
Check
Check Temperature Too Far
from Setpoint
20
Check
Check Defrost Time Too Long
22
Check
Check Capacity Test 1 Error
25
Check
Check Evaporator Temperature
Test Error
26
Check
Vapor Injection Valve Error
27
Check
Check Heat Capacity Test Error
31
Check
Low Pressure Cutout Error
32
Check
Check Condenser Air Sensor
Open Circuit
33
Check
Check Condenser Air Sensor
Short Circuit
34
Check
Check Ambient Air Sensor Open
Circuit
35
Check
Check Ambient Air Sensor Short
Circuit
43
Check
Check Return Air Temperature
52
Check
Check Probe Error
53
Check
Check High Pressure Cutout
Switch Off Error
54
Check
Check High Pressure Cutout
Switch On Error
56
Shutdown
Shutdown Compressor
Temperature Too High
57
Check
AFAM Device Error
58
Check
Check Phase Sensor Error
59
Check
Check Delta Current Error
60
Check
Check Humidity Sensor Error
68
Check
AFAM Gas Analyzer Error
69
Check
Gas Analyzer Calibration Error
97
Check
Log Compressor Sensor Open
Circuit
98
Check
Log Compressor Sensor Short
Circuit
115
Check
Probe Error Return & Evaporator
116
Check
Probe Error Return & Supply
117
Check
Probe Error Supply RH & LH
118
Check
High Refrigerant Level
119
Check
Digital Valve Error
120
Check
Suction Pressure Sensor Error
121
Check
Discharge Pressure Sensor
Error
122
Check
CO2 Sensor Calibration Error
Alarm List (Continued)
Alarm
Code
Type
Description
Содержание 098916
Страница 2: ...MAGNUM TK 51122 4 MM Rev 6 02 06 Copyright 2004 Thermo King Corp Minneapolis MN USA Printed in USA...
Страница 5: ......
Страница 11: ...Table of Contents 10...
Страница 19: ...Service Guide 18...
Страница 28: ...Specifications 27 Figure 2 Physical Specifications AMA313...
Страница 41: ...Unit Description Features Options 40...
Страница 105: ...Operating Instructions 104...
Страница 155: ...Servicing The Unit 154...
Страница 187: ...Index 186...
Страница 189: ...Wiring and Schematic Diagrams Index 188...
Страница 190: ...189 Wiring Schematic...
Страница 191: ...190 Wiring Diagram Page 1 of 2...
Страница 192: ...191 Wiring Diagram Page 2 of 2...