Main Menu
74
Humidity Setpoint
The relative humidity setpoint can be set from 50 to99 percent.
HUMIDITY SENSOR mounted must be selected under the CONFIGURATION/OPTIONS/HUMIDITY
SENSOR for HUMIDITY SETPOINT to be active or visible. See complete description of HUMIDITY
CONTROL under Operating Theory section of his manual.
Figure 51: Humidity Setpoint
AVL (Air Ventilation Logging)
The Fresh Air Exchange Recorder (AVL) detects vent disk movement and automatically displays a value
in the LCD display for values of 0 to 125 m3/h. For settings greater than 125 m3/h the technician must set
the AVL Open Value to match the notched setting on the Fresh Air Exchange Vent.
AVL must be selected under the CONFIGURATION/OPTIONS/CONTROLLED ATMOSPHERE (CA)
and AVL SENSOR must be mounted under CONFIGURATION/OPTIONS/AVL OPTION for AVL to be
active or visible.
Figure 52: Enabling AVL
Содержание 098203
Страница 2: ......
Страница 3: ...MAGNUM TK 60275 4 MM Rev 3 08 15 Copyright 2012 Ingersoll Rand EMEIA Printed in Ireland...
Страница 193: ...Refrigeration Maintenance 191 Figure 163 Filter Drier...
Страница 200: ...Refrigeration Maintenance 198 Figure 169 Receiver Tank Figure 170 Water Cooled Condenser Tank...
Страница 257: ...255 Schematic Diagram RELEASED 19 Sep 2013...
Страница 258: ...256 Wiring Diagram Page 1 of 2 RELEASED 19 Sep 2013...
Страница 259: ...257 Wiring Diagram Page 2 of 2 RELEASED 19 Sep 2013...
Страница 263: ......