Commissioning
Setting up the appliance
Place the appliance freely on the floor in
the room. The appliance must stand on
firm, level, horizontal and non-flammable
ground. There should be no flammable
objects and/or no objects / obstacles ob-
structing the air circulation within a mini-
mum distance of one metre. Connect the
appliance to the mains using a suitable
mains extension lead.
Use a 5-pole three-phase extension cable
with a minimum cable cross-section of
2.5 mm² (CEE 16A, cable cross-section 2.5
mm²). Make sure that the mains voltage
corresponds to the rated voltage of the
appliance as indicated on the type plate.
Attention:
Please observe the safety
notes on page 06-07.
Operating instructions | Commissioning
Operating instructions | Operation of the machine
Operating the appliance
Starting the appliance
Press the start button until the operating
control lamp lights up.
Setting the heat output
With the 4.5 and 9 kW circuit-breakers,
you can set a heat output of 4.5 kW, 9.0
kW or only air circulation without heat-
ing.
Temperature display
The current actual temperature is shown
in the top line of the display. After press-
ing the set button, the upper line of the
display shows "Set" and the lower line
shows the set control temperature (tar-
get temperature).
Control temperature
(target temperature)
The control temperature can be set be-
tween 30 °C and 70 °C in increments of
1 °C. In order to set the control temper-
ature (target temperature), press the set
key until "SET" appears on the top line of
the display.
The target temperature is shown on the
bottom line of the display. The target
temperature can be adjusted by pressing
the temperature adjustment b
and -. Press the SET button again to save
and accept the selected target temper-
ature. If the SET button is not pressed
within 3 seconds, the SET temperature is
not adjusted and the appliance contin-
ues to operate with the previous temper-
ature setting.
Attention:
When setting the control
temperature, observe the safety notes
on page 06-07.
Further display functions
Pressing the information button displays
the programme version of the appliance
software (Pro), the operating hours since
the unit was started (t-1), the operating
hours after the control temperature has
been reached (t-2) and the total operat-
ing hours of the appliance (t-3) in chron-
ological order.