2
1. The heater should be installed by a qualified
plumber. We recommend the use of a knee pad
when installing this product. Cut the opening in
the plinth to the size shown in the table. Use
method A or B.
Model
Width A
Height
B*
KPH 2400
540mm
97mm
* The overall height of the grille is 100mm. Use
care when cutting the opening.
A
A
B
B
2. Fit isolating valves (not supplied) to the
system flow and return pipes. Failure to fit
isolating valves may mean that the
product is not serviceable in the event of
failure. Remove and discard the two
rubber protection bungs in the copper
pipes and connect the flexible hoses
between system pipework and heater.
Open the isolating valves and check for
leaks.
N.B. either pipe may be used on flow or return.
3. Vent air through bleed screw if
necessary with flat blade screw
driver.
Flate heat
screw driver
Bleed Valve
I
O
II
4.
Isolate electrical supply and
connect the heater electric cable to
the fused spur (3A). Ensure the
fused spur is not directly above the
heater and is accessible after
installation is complete. Electrical
works should be carried out by a
qualified electrician, in compliance
with local regulations
I
O
II
Fused Spur
5. Position heater, making sure the
flexible hoses is not kinked and the
electrical cable is not snagged.
Flow
Return