background image

 

 

 

 

Installation & User Guide 

 

Kitchen Plinth Heater models 
  KPH 2400C and KPH-2400W 

 
 

 

 

                                          Classic models   

 

 

 

 

 

      Wireless models 

 
 

Introduction 

 
This heater is intended to install behind the plinth in the space under the kitchen cupboards. However, 
it can be installed in similar kind of application. 

 
This unit is made for two pipe pumped central heating systems. Flow and return and pipes should be 
connected as per drawing mentioned in page 2.This unit should not be installed in one pipe system.   

 
To allow enough airflow a minimum clearance of 20-25mm from the top of the unit to the any shelving. 
This unit must be installed of flat surface to avoid vibration. 

 
Isolating valves (not supplied) should be fitted to both pipes (flow & return) to allow easy servicing. 
The flexible hose should be fitted to both pipe (flow & return) to allow easy servicing.   
 

This unit should not be installed in bath room or high humid areas. 
 
Electrical connections should be via 3A fused spur and it should be accessible after the installation. 

 
The following items should be in the carton: 

Product complete with pre-wired mains cable. 

Flexible connecting Hoses   
Fitted Grille 
Fixing screws (2) with screw caps   
Wireless Thermostat (Models KPH 2400-W Only) 

In the event of any items missing or visibly damaged on unpackaging, please contact us on email 
before starting any installation. 
 

       

Installation: 

Содержание KPH 2400C

Страница 1: ...shelving This unit must be installed of flat surface to avoid vibration Isolating valves not supplied should be fitted to both pipes flow return to allow easy servicing The flexible hose should be fitted to both pipe flow return to allow easy servicing This unit should not be installed in bath room or high humid areas Electrical connections should be via 3A fused spur and it should be accessible a...

Страница 2: ...protection bungs in the copper pipes and connect the flexible hoses between system pipework and heater Open the isolating valves and check for leaks N B either pipe may be used on flow or return 3 Vent air through bleed screw if necessary with flat blade screw driver Flate heat screw driver Bleed Valve I O II 4 Isolate electrical supply and connect the heater electric cable to the fused spur 3A En...

Страница 3: ...ating system if Kitchen plinth heater is installed on the same circuit as panel radiators 8 When the installation is working correctly remember to reset any room thermostat s to its normal setting 1 Fan does not run on any switch setting a Check the power supply is switched ON b Check fuse in fused spur c Check the wiring connections at the fused spur d Check the pipes on the side of the unit are ...

Страница 4: ... details of the nearest approved authorised treatment facility Proper recycling and waste disposal will help conserve resources whilst preventing detrimental effects on our health and the environment This product is covered by a standard 12 month product replacement warranty against any manufacturing defects or workmanship Warranty is only for the main product not for any accessories that comes wi...

Отзывы: