The burner should now ignite and remain in operation
until the set temperature is reached.
If any ignition faults or malfunctions occur, the burner
performs a “LOCKOUT SHUTDOWN”. This is shown by
the red button light on the burner and by the warning
light on the control panel.
b
If a “LOCKOUT SHUTDOWN” occurs, wait about
30 seconds before resetting the burner.
To reset the burner, press the red button light on the
burner and wait until the flame ignites.
Repeat this operation 2 -3 times at the most. If the prob-
lem persists after that, call
THERMITAL
’s Technical
Assistance Service.
If you need to shut down the system for a short period,
proceed as follows.
- Turn the control panel power switch OFF and make
sure that the green power indicator goes out.
- Turn the mains power switch OFF.
b
Do NOT perform this procedure if outdoor tem-
perature falls below ZERO (risk of freezing).
Then proceed as follows:
- Make the settings as instructed in the instruction man-
ual for your control panel.
- Make sure that the temperature controller or timer /
room thermostat is set to “frost protection” mode.
ON
OFF
15
ENGLISH
SYSTEM MANAGER
TEMPORARY SHUTDOWN
Содержание 20034707