Servicing & Maintenance

 

 

3.1 Valves 

 
All valves are selected to ensure that the unit gives 
optimum performance. Input valves are always 
matched when the unit is calibrated to ensure 
consistent performance across both channels. 
 
Although Thermionic Culture Ltd guarantees the 
valves for twelve months, they can last for up to 
twenty years. 
 
Spares can be obtained in matched pairs from 
Thermionic Culture Ltd.  
 

3.2 

Operating voltage / Fuses 

 
The Phoenix Valve Compressor is factory set to 
operate from a 230V 50/60Hz AC mains supply It can 
be set to operate from 115V AC by sliding the voltage 
selector switch on the rear panel to the ‘115V’ 
position. 
 
NOTE: If the mains supply voltage is reduced to 115V, 
then the mains fuse MUST be increased to 1.6A in 
accordance with the following table: 
 

Operating Voltage 

Fuse Rating 

115V 

T1.6A 20mm type 

230V 

T800mA 20mm type 

 
 

©

Thermionic Culture Ltd, January 1999 

7

 

Содержание The Phoenix

Страница 1: ...CULTURE THERMIONIC T P HE HOENIX valve compressor OPERATING MANUAL...

Страница 2: ...from the mains supply before any of the covers are removed Please also note that the power supply capacitors within this unit can remain charged even after the mains supply has been disconnected It is...

Страница 3: ...tion 4 2 1 Output trim 4 2 2 Gain 4 2 3 Attack 4 2 4 Release 4 2 5 Threshold 5 2 6 Bypass 5 2 7 Link 5 2 8 Pre sets 6 2 9 Meters 6 3 Servicing Maintenance 7 3 1 Valves 7 3 2 Operating voltage Fuses 7...

Страница 4: ...as a pair of mono compressors It has a soft knee or variable mu characteristic in that the compression ratio increases with the amount of compression being used Initial compression is 1 2 1 increasin...

Страница 5: ...The attack control varies the rate at which the compressor starts to react Attack rates of between 4ms fully anti clockwise and 120ms fully clockwise can be achieved This control is typically set to...

Страница 6: ...nk Links the two compressors for compressing a stereo track All controls are still in use so both channels should be set to around the same setting Ideally a 1kHz tone should be used to setup the leve...

Страница 7: ...nd the meters are used to adjust the zero points of the meters They can be adjusted with a long thin screwdriver without removing the top cover of the compressor Zero readings will vary a little with...

Страница 8: ...n be obtained in matched pairs from Thermionic Culture Ltd 3 2 Operating voltage Fuses The Phoenix Valve Compressor is factory set to operate from a 230V 50 60Hz AC mains supply It can be set to opera...

Страница 9: ...time 0 004s to 0 12s Release time 0 06s to 2 2s Output impedance 600 Distortion will increase with compression typically 0 2 0 25 at 1kHz 100Hz with 8dB compression VALVE COMPLEMENT 2 ea Input Compres...

Страница 10: ...Thermionic Culture Ltd 83 Collins Meadow Harlow Essex CM19 4EL UK Tel 44 0 1279 414770 Fax 44 0 1279 412233 Thermionic Culture Ltd January 1999 Printed in UK...

Отзывы: