8
English
Recirculation
The air is cleaned with the help of active carbon filters, after which it is returned to the
room. The carbon filter brackets for attaching them are ordered as a set and are an
option that can be ordered. See the catalogue for the product number.
Fitting of carbon filters
The carbon filter is fitted
inside the metal filter. Use a screwdriver if needed.
•
•
Power Supply
The range hood shall be connected to 230V in accordance with the high-voltage
regulations.
Replacement of bulbs
Use a flat screwdriver or other suitable tool to lift and remove the overlying light
fitting. Replace the damaged bulb. Use only halogen bulbs on max. 20W and
avoid contact with the skin. Replace the light fitting again (pressure protection).
Finger touch panel:
ON/OFF button for light.
OFF button for motor.
ON button and motor speed selector 1-2-3.
ON button - turbo function
This speed should be used when the concentration of food odour or smell is particularly strong. The
turbo function will run for approximately 5 minutes and then automatically return to the previously
configured speed (1, 2 or 3) or turn off if no speed has been selected. Press the
STOP button for the
motor
or the
speed selector 1-2-3
to turn off the turbo function before the 5 minutes have passed.
Filter clean indicator
Light diode for cleaning of metal filters. (In the latter case a diode at the letter F will blink). To reset
this function, hold down the
OFF-button for the motor
for about 5 seconds, after which you will
hear a beep sound and the readout will be reset.