background image

Kubisma

58

Содержание Kubisma

Страница 1: ...Kubisma Dansk Svenska Norsk English Deutsch Espa ol ret effektiv...

Страница 2: ...ntering Kubisma 2 Bem rk Aftr kket fra emfanget m ikke tilsluttes eksisterende varmluftssystem eller skorsten V gmontering Bem rk Aftr kket fra emfanget m ikke tilsluttes eksisterende varmluftssystem...

Страница 3: ...abler 1 stk m rket 230 V 1 stk m rket motor Her er monteret et forl ngerled beregnet til sammenkobling med stikprop fra ekstern motor Montering af flexslange fig 2 Flexslange 160 mm f res gennem hul i...

Страница 4: ...max CKB 2000 Arb temperatur 10 50 C Minimumtrimmer Mindst 80 130V AC Filter Panel Lys Reng ring af st lfilter husk at slukke for str mmen f r du tager filtret ud De 2 fingerskruer 1 l snes fjernes De...

Страница 5: ...fter et tidsinterval ca 30 timer angiver lysdioden at fedtfiltrene skal reng res Genindstilling af lysdiode Hold sluk knappen inde i ca 15 sekunder indtil lysdioden slukker Ekstra funktioner Styring a...

Страница 6: ...S fremt kondens lyd isoleringsboks anvendes Kubisma 6...

Страница 7: ...60 mm 3 der kommer fra emfang monteres p indsugningsflange P afgangsflangen monteres flexslange 160 200 mm 4 og f res videre til tagh tte eller v gflange El tilslutning 5 El kabel fra emfang m rket mo...

Страница 8: ...Kubisma 8...

Страница 9: ...fastf res til tag 2 Vinge p tagfundament er variabel s ledes at denne kan f lge tagets h ldning 3 4 Indd kning bly tagpap eller tegl foretages 5 Tilslutningsflange r r med kontraspj ld og flexslange t...

Страница 10: ...Kubisma 10...

Страница 11: ...e synlige indvendig 3 V gventilator monteres udvendig 4 Flexslange 160 mm monteres indvendig 5 El kabel fra emfang m rket motor monteret med forl ngerled sammenkobles med ledning fra v gventilator 6 7...

Страница 12: ...montering Observera Utsuget fr n spiskupan f r inte anslutas till existerande varmluftssystem eller skorsten V ggmontering Observera Utsuget fr n spiskupan f r inte anslutas till existerande varmluft...

Страница 13: ...extern motor OBS Bl ledningar f r ej sammankopplas Montering av slang tillbeh r fig 2 Eventuell anslutningsslang 160 mm monteras p det nedstickande ventilationsr ret med hj lp av slangkl mma Montering...

Страница 14: ...ing max 10A Max belastning 4A 500W Arb temperatur 10 50 C Filter Kontrollpanel Belysning Reng ring av filter Bryt str mmen till fl kten innan Ni b rjar Lossa de tv fingerskruvarna 1 i botten Lossa bot...

Страница 15: ...jusdioden att fettfiltren skall reng ras terinst llning av ljusdiod H ll in stoppknappen i ca 15 sekunder tills ljusdioden sl cks Extra funktioner Reglering av bostadsventilation Anv ndaren har m jlig...

Страница 16: ...Kubisma 16 Om kondens ljud isoleringsl da anv ndes...

Страница 17: ...g 160 mm 3 som kommer fr n spiskupan monteras p insugningsfl nsen Flexslangen 160 200 mm 4 monteras p utloppsfl nsen och f rs vidare till takkupan eller v ggfl nsen Elanslutning 5 Elkabeln fr n kupan...

Страница 18: ...Kubisma 18...

Страница 19: ...damentet skruvas fast p taket 2 Vingen p takfundamentet r variabel s att den kan f lja takets lutning 3 4 T ckning bly eller takpapp eller tegel genomf res 5 Anslutningsfl ns r r med backspj ll och fl...

Страница 20: ...Kubisma 20...

Страница 21: ...skall vara synligt inv ndigt 3 V ggfl kten monteras utv ndigt 4 Flexslang 160 mm monteras inv ndigt 5 Elkabeln fr n kupan m rkt motor monterad med f rl ngningskontakt sammankopplas med ledning fr n v...

Страница 22: ...Bemerk Avtrekket fra hetten kan ikke tilkobles eksisterende varmluftsystem sentralventilasjon eller skorstein Veggmontering Bemerk Avtrekket fra hetten kan ikke tilkobles eksisterende varmluftsystem...

Страница 23: ...ng til str m nettet uten stikk skal det v re en fler polet avbryter mellom hetten og str m nettet Av bryter skal ha en minimumsavstand p 3 mm mellom kontaktene og v re dimensjonert i henhold til sterk...

Страница 24: ...ubisma Spenning 230V AC 6 10 50 Hz Sikringskurs maks 10A Maks belastning 4A 500W Arb temperatur 10 50 C Filter Panel Lys Rengj ring av st lfiltre husk sl av viftemotoren f r fjerning av fettefiltrene...

Страница 25: ...dioden at st lfiltrene skal rengj res Nullstilling av lysdiode for rengj ring av fettfiltre hold slukk knappen inne i ca 15 sekunder til lysdioden slukker Ekstra funksjoner Styring av intervallventila...

Страница 26: ...Kubisma 26 S fremt kondens lyd isoleringsboks benyttes...

Страница 27: ...mm 3 som kommer fra viften monteres p innsugingsflense Fleksislangen 160 200 mm 4 monteres p avgangsflense og f res videre til takhetten eller veggflense El tilslutning 5 El kabel fra viften merket mo...

Страница 28: ...Kubisma 28...

Страница 29: ...mentet festes til taket 2 Vingene p takfundamentet er regulerbare slik at de f lger takets helling 3 4 Inndekning bly takpapp eller tegl foretas 5 Tilslutningsflens r r med kontraspjeld og fleksislang...

Страница 30: ...Kubisma 30...

Страница 31: ...murr r skal v re synlige indvendig 3 V gventilator monteres udvendig 4 Flexslange 160 mm monteres indvendig 5 El kabel fra emfang m rket motor monteret med forl ngerled sammenkobles med ledning fra v...

Страница 32: ...hot air system or chimney Important If the cable is defect it is to be changed by an authorized electrician Installation on wall Attention Do not connect the outlet of the cooker hood to an existing h...

Страница 33: ...connection to the electric net without socket it is necessary that a multipolar switch is between the cooker hood and the electric net The switch is to have a minimum distance of 3 mm between the cont...

Страница 34: ...nd maximum CKB 2000 Working temperature 10 50 C Minimum trimming at least 80 130V AC Filter Panel Light Filter cleaning remember to turn off the electricity power supply before taking out the filters...

Страница 35: ...light diode Hold the switch off button for about 15 seconds until the light diode is switched off Extra Functionings Control of house ventilation Through the control panel the user has the possibility...

Страница 36: ...Kubisma 36 If a condensingsound isolation box is used...

Страница 37: ...e hose D160 mm 3 from the canopy is installed on the induction flange The flexible hose D160 200 mm 4 is installed on the output flange and is further led to the roof cowl or the wall flange Electric...

Страница 38: ...Kubisma 38...

Страница 39: ...ened to the roof 2 Wings on roof foundation are variable to make them able to follow the slope of the roof 3 4 Covering lead roofing felt or tile is carried out 5 Connection flange pipe with counter d...

Страница 40: ...Kubisma 40...

Страница 41: ...wall pipe must be visible inside 3 Wall ventilator should be installed outside 4 Flexible hose D 160 mm is installed inside 5 Lead from canopy marked engine mounted with extension lead is connected to...

Страница 42: ...den Wichtig Falls die Leitung defekt ist muss diese von einem zugelassenen Elektromonteur ausgetauscht werden Wandmontage Achtung Der Abzug vom Dunstabzug darf mit bestehendem Warmluftsystem oder Scho...

Страница 43: ...von einem externen Motor berechnet ist Bei direktem Anschluss an das Elektronetz ohne Stecker ist es notwendig dass es einen mehrpoligen Schalter zwischen dem Dunstabzug und dem Elektronetz gibt Der...

Страница 44: ...0 50 Hz Vorsicherung max 13A Max Belastung 4A total und max CKB 2000 Arbeitstemperatur 10 50 C Minimumtrimmer Mindestens 80 130V AC Filter Panel Licht Reinigung des Filters vor dem Ausnehmen des Filte...

Страница 45: ...Fettfilter gereinigt werden m ssen Wiedereinstellung der Leuchtdiode Den Abschalterknopf ca 15 Sekunden dr cken bis die Leuchtdiode erlischt Weitere Funktionen Steuerung der Wohnungsventilation Durch...

Страница 46: ...Kubisma 46 Falls Kondens Ger us ch wird eine Isolierungsbox angewendet...

Страница 47: ...160 mm 3 der Abzugseinrichtung wird auf den Einsaugflansch montiert Auf dem Ausgangsflansch wird die Flexschlange 160 200 mm 4 montiert und zur Dachhaube oder zum Wandflansch weitergeleitet El Anschl...

Страница 48: ...Kubisma 48...

Страница 49: ...hfundament wird am Dach festgemacht 2 Die Fl gel am Dachfundament sind variabel so da diese der Neigung des Daches folgen k nnen 3 4 Eindeckung Blei Dachpappe oder Ziegel wird durchgef hrt 5 Anschlu f...

Страница 50: ...Kubisma 50...

Страница 51: ...hrs mu inwendig sichtbar werden 3 Der Wandventilator wird au en montiert 4 Die Flexschlange 160 mm wird innen montiert 5 El Kabel von der Abzugseinrichtung mit Motor markiert mit Verl ngerungsgelenk m...

Страница 52: ...sion pendular Importante No conectar la salida de la campana a salida existente de aire caliente o chimenea Montaje fijado en la pared Importante No conectar la salida de la campana a salida existente...

Страница 53: ...a un interruptor con varios polos entre la campana y la fuente de alimentaci n el ctrica El interruptor tiene que tener una distancia m nima de 3 mm entre los contactos y ha de ser dimensionado seg n...

Страница 54: ...x 13 A Carga m xima 4Aentotal yunm ximodeCKB2000 Temperatura de funcionamiento 10 50 C Compensador de tensi n m n 80 130V AC Filtro Panel Luz Limpieza de los filtros Recuerda desconectar la campana de...

Страница 55: ...oximado de 30 horas la pantalla indica CL que los filtros deben ser limpiados Reset del diodo Apretar el bot n de apagar durante aproximadamente 15 segundos Hasta que el diodo se apague Funciones adic...

Страница 56: ...Kubisma 56 En caso de utilizar un dispositivo aislante de sonido condensaci n...

Страница 57: ...del extractor se monta en la brida de aspiraci n En la brida de salida se monta la manguera flexible 160 200 mm 4 y se conduce al sombrerete o a la brida de la pared Conexi n a la corriente el ctrica...

Страница 58: ...Kubisma 58...

Страница 59: ...l tejado 2 Las alas del fundamento del tejado son variables con el fin de que se adapten a las inclinaciones de los tejados 3 4 Llevar a cabo el recubrimiento de plomo cart n bituminoso o teja 5 Conec...

Страница 60: ...Kubisma 60...

Страница 61: ...cm del tubo deben ser visibles en el interior 3 Montar el extractor de pared en el lado exterior 4 Montar el tubo flexible 160 mm en el interior 5 Conectar el cable el ctrico del extractor marcado mo...

Страница 62: ...21 90 21 E mail info thermex no Thermex Scandinavia S A C Noi del Sucre 42 08840 Viladecans Tel 93 637 30 03 Fax 93 637 29 02 E mail info thermex es Danhood Ltd UK Phone 01702 468241 Thermex Scandina...

Отзывы: