background image

DOC NO. 81078 

Page 1 of 18 

Rev D 3/06 GM 

 

Installation Instructions 

 

Steam Shower Series 

With Fast Start Technology 

Manufacture Post 2005 

 

If you are a plumber installing this unit, please leave 

this owners manual & warranty card with the owner 

when you finish the installation. 

 

This Instruction supercedes all previous information provided by ThermaSol 

 

Thank You! 

 

CONSUMER WARNING

 

 

 

DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED YOUR DOCTOR AND RECEIVED WRITTEN PERMISSION TO DO SO. 
USE OF THIS PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH. 

 

 

STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS  “ON”, UP TO ONE HOUR FROM THE 
TIME THE UNIT IS OFF. SEVERE BURN WILL OCCUR IF YOU COME IN CONTACT WITH THE STEAMHEAD OR STEAM EMITTING FROM 
THE STEAMHEAD. 

 

 

NEVER ATTEMPT TO FILL AROMA THERAPY RESERVOIR ON THE STEAMHEAD WHEN UNIT IS IN THE “ON” POSITION. SEVERE 
BURNS WILL OCCUR. 

 

 

DO NOT USE THERMASOL AROMA THERAPY OILS OR SKIN CARE PRODUCTS OR ANY PRODUCT IN CONJUNCTION WITH YOUR 
THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE 
HAZARDOUS TO YOUR HEALTH. 

 

 

YOUR SHOWER MAY BE A SLIP AND FALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER 
REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION. SLIPPING AND FALLING INTO THE STEAMHEAD 
ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS, OR PHYSICAL INJURY. 

 

 

DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS, AS THIS CAN BE HAZARDOUS TO YOUR 
HEALTH. 

 

 

IF YOU ARE FEELING UNCOMFORTABLE, DIZZY, FAINT, OR STARTING TO FALL ASLEEP IMMEDIATELY EXIT THE STEAM ROOM. 

 

 

DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT. 

 

Note:  Before contacting Customer Service for Technical Support, please have the model number, 
serial number and date code (located on a circle to the lower right of the serial number), include 
all numbers and letters. 

 

Headquarters & Technical Support 

2255 Union Place, Simi Valley, CA  93065 – (800) 776-0711 

Mon – Thur 7:00 – 5:00, Fri 8:00 – 12:00 PST 

 

Eastern Sales Office 

26 Industrial Avenue, Fairview, NJ  07022 – (800) 631-1601 

Mon – Thur 7:00 – 5:00, Fri 8:00 – 12:00 EST 

www.thermasol.com 

Содержание SS-140

Страница 1: ...HERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH YOUR SHOWER MAY BE A SLIP AND FALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS ...

Страница 2: ...age 2 of 18 Rev D 3 06 GM NOTICE WARNING LABEL THERMASOL CONTROL THERMASOL STEAMHEAD SHOWER FLOOR YOU MUST ATTACH THIS STATIC CLING USER WARNING LABEL IN THE SHOWER NEXT TO THE CONTROL UPON COMPLETION OF INSTALLATION ...

Страница 3: ...generators are designed to build NO PRESSURE during operation This is for your safety Note Failure to follow installation instructions specifically will cause the warranty to be void Figure 1 Note The generator must be mounted level with all connections on top PRESSURE RELIEF VALVE CONTROL CABLE INPUT FRONT OF GENERATOR ACCESS PANEL POWERFLUSH BALL VALVE IN CLOSED POSITION WATER INLET 17 12 AT PIP...

Страница 4: ...Tools Needed Pipe wrench Tubing cutter Wire cutters or wire strippers Adjustable wrench Screwdrivers phillips regular Solder Flux 1 1 16 masonry drill bit 2 1 2 hole saw for NoTouch Steamhead Drill motor Propane torch Other tools as required Note ThermaSol steam bath generators are for indoor use only They should never be located outside the home Note ThermaSol steam bath generators are NOT design...

Страница 5: ...LL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY WARNING STEAM IS HOT DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS ON UP TO ONE HOUR AFTER IT HAS SHUT OFF SEV...

Страница 6: ...ove any silt or other materials that may be in the line 10 Make the final connection and turn on water All ThermaSol generators are equipped with an automatic water fill system The water will stop after unit is filled 11 The steam line can run up down or horizontal but cannot run down and then up If it does a steam trap will be produced at the low point blocking the flow of steam Do not plumb a tr...

Страница 7: ... all connections on top COUPLER ONETOUCH CONTROL STEAMHEAD TEE IMPORTANT LOCATE THE STEAMHEAD 12 OFF THE SHOWER FLOOR OR BATHTUB RIM AND 6 FROM ANY CORNER STEAMHEAD IS TO BE MOUNTED FAR AS POSSIBLE FROM TYPICAL BATHING POSITION SEATED OR STANDING AND AS FAR FROM CONTROL AS POSSIBLE WHILE MAINTAINING A 60 CONTROL HEIGHT PRESSURE RELIEF VALVE 50 FOOT CONTROL CABLE SHUT OFF VALVE WATER INLLET ELITE C...

Страница 8: ...LL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY WARNING STEAM IS HOT DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS ON UP TO ONE HOUR AFTER IT HAS SHUT OFF SEV...

Страница 9: ...1 2 hole cutting tool Other tools as required 1 Drill a 2 1 2 diameter hole in the shower wall or wall above the bathtub rim for the steam outlet line see Figure 4 CAUTION The Steamhead is hot and should not be located near a seat or bench We recommend locating the Steamhead on the fixture wall Ensure that all Plumbing is Firmly Secured Figure 4 STEAMHEAD STEAMHEAD HOUSING 2 1 2 HOLE 1 2 PIPE SHOW...

Страница 10: ...the housing be sure that the aromatherapy fill channels are facing upwards see Figure 5 To ensure that no moisture gets behind the Steamhead and into the wall place a generous bead of waterproof silicone around the Steamhead use the machined grove located on the back of the Steamhead as a guide Be sure that within the housing there isn t any debris and the two O rings are in place on the Steamhead...

Страница 11: ...ALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY WARNING STEAM IS HOT DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS ON UP TO ONE HOUR AFTER IT HAS SHUT OFF SE...

Страница 12: ...uge Breaker Size Factory Sized Cu Ft MAX AMP draw 240 VAC K W SS Acrylic 1 10 20 Acrylic Insert 17 3 5 SS 84 1 10 30 84 28 6 0 SS 140 1 8 40 140 37 8 0 SS 240 1 8 50 240 46 10 SS 395 1 6 60 395 55 12 SS 600 1 4 80 500 69 15 Electrical Questions 800 776 0711 for Technical Support Warning Each generator should be wired to their own separate breaker 1 Turn off all electricity to the working area at t...

Страница 13: ...ALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY WARNING STEAM IS HOT DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS ON UP TO ONE HOUR AFTER IT HAS SHUT OFF SE...

Страница 14: ... 16 diameter hole Plug the modular connector of the control into one end of the coupler Plug the control cable s from the generator into the other end of the coupler Route the cable so that the coupler is located ABOVE the hole in the wall DO NOT pinch nail staple wedge etc the cable DO NOT wrap the cable around steam line or otherwise route it in such a manner that the hot steam line could melt t...

Страница 15: ... to harm the wall control with the tape Let dry for 24 hours before using steam bath 10 Refer to operation instructions for control functions Note Failure to follow installation instructions specifically will cause the warranty to be void COAT THE BACK COMPETELY WITH SUPPLIED WATERPROOF SILICONE TO COMPLETELY SEAL THE CONTROL TO THE WALL AND NOT ALLOW MOISTURE BEHIND IT 1 1 16 DRILL HOLE IN WALL F...

Страница 16: ...eam Generator 1 Power on the control and set the timer to 45 minutes Open the powerflush ball valve located on top of the generator refer to Figure 1 for 5 7 minutes then close Allow generator to finish the 45 minute session See following document for more detail about powerflushing ThermaSol recommends one powerflush cycle after every fifty uses Warning IT IS IMPORTANT THAT NO ONE BE INSIDE THE S...

Страница 17: ... set the timer to 45 minutes 2 Open the powerflush ball valve located on top of the generator for 5 7 minutes 3 After 5 7 minutes close the powerflush ball valve 4 Allow generator to finish the 45 minute session ThermaSol recommends one powerflush cycle after every fifty uses or at least twice a year Warning IT IS IMPORTANT THAT NO ONE BE INSIDE THE SHOWER ENCLOSURE DURING THE POWERFLUSH CLEANING ...

Страница 18: ...ALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY WARNING STEAM IS HOT DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS ON UP TO ONE HOUR AFTER IT HAS SHUT OFF SE...