Signature Series Control Installation Instructions

Connect the data cable to steam generator connector.
(The other end of the cable runs to the back of the control in 
the the shower location or to the SWM-2 or PDM if present.

Route the data cable (included with 
generator) through the finished wall 
to the back side of the control. 
The other end of the cable runs to 
the steam generator location or if 
present to SWM-2 or PDM.

NOTE: It is recommended to run 
the cable through electrical conduit.

DO NOT pinch, nail, staple, wedge, or 
bind the data cable. 

DO NOT wrap the data cable around 
steam line or route it in a manner so 
that the hot steam line could melt 
the cable.

Any damage to the control cable 
will result in the control not working 
properly.

Carefully connect the data cable to 
the generator and control BEFORE 
turning power on to the generator.

"ON" 
Turn Clockwise

"OFF" Turn 
Counter Clockwise

• Do not staple, strain or damage data cable
• Align pins to receptacle visually before tightening
• Do not force plug
• Hand tighten only

Connector 
Detail

Back of 
control 
or side of 
generator

Back of Control

Side of generator

Contact pins

Contact pins Cable ends

Back of 
control 
or side of 
generator

4

 

Control Installation and Data Cable Connection

81173_NC 3/16

Содержание Signature Series

Страница 1: ...ELECT STEAM Installation Manual For Tutorials and Troubleshooting visit www thermasol com solutions From top L to R SET XX Traditional SEM XX Modern SEMR XX Modern Recessed SEC XX Contemporary SER XX Regency OVER 55 YEARS OF STEAM SHOWER INNOVATION ...

Страница 2: ...HEALTH YOUR SHOWER MAY BE A SLIP AND FALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY IF YOU ARE FEELING UNCOMFORTABLE DIZZY FAINT OR STARTING TO FALL ASLEEP IMMEDIATELY EXIT ...

Страница 3: ...le Connection Shower wall Materials needed o Signature Series control o CAN Bus Cable included with generator o Silicone o Other materials as required Tools needed o 1 2 drill for surface mount o Follow pre installation instruction on page 5 for recessed mount controls o Drill motor o Other tools as required Controller Contemporary style shown here Installation instructions warranty static cling w...

Страница 4: ...ed to run the cable through electrical conduit DO NOT pinch nail staple wedge or bind the data cable DO NOT wrap the data cable around steam line or route it in a manner so that the hot steam line could melt the cable Any damage to the control cable will result in the control not working properly Carefully connect the data cable to the generator and control BEFORE turning power on to the generator...

Страница 5: ...h to wall Connect cable so it is not lost in wall Test fit for flushness Step 3 IMPORTANT Fully test the control system prior to silicone Once desired fit is achieved coat back of con trol face with supplied silicone Firmly press to wall surface and wipe excess silicone from around control Tape into LEVEL position and let dry for 24 hours before using steam bath Data Cable Step 1 Coat the entire g...

Страница 6: ...eft and to the right of the Select Return button Press button Increase the temperature by touching the UP symbol until desired temperature is displayed Press Select Return button Reduce the temperature by touching the down symbol until desired temperature is displayed Press Select Return button Setting the timer Press the or button until you reach the time menu Press Select Return button Set the t...

Страница 7: ...lustrative purposes only Consult with qualified professional for steam room construction details 7 THERMASOL COM I 800 776 0711 7 Trouble Shooting and Error Codes Visit www thermasol com solutions Click on Troubleshoot then click on Signature Series Control Error Codes 81173_NC 3 16 ...

Страница 8: ...1958 STEAM WAY ROUND ROCK TX 78665 PHONE 800 776 0711 SUPPORT THERMASOL COM WWW THERMASOL COM WWW THERMASOL COM SOLUTIONS 81173_NC 3 16 ...

Отзывы: