background image

Digital Shower Valve

THERMASOL.COM  

I

  800.776.0711

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. 

9

8

 

Install Valve System Controller

9

 

Remove Inlet Retaining Bolt

15V    ACCU     

             EXT   

        RS

-232      MOTO

R              TLI   

                  

 AUX

    

15V    ACCU  

                EXT  

         RS-23

2      MOTOR 

             TLI  

                    

AUX

    

Содержание 65259207354

Страница 1: ...OVER 60 YEARS OF STEAM SHOWER INNOVATION Installation Manual For Tutorials and Troubleshooting visit www thermasol com solutions Digital Shower ThermaTouch 7 Package ...

Страница 2: ...ThermaTouch Control OVER 60 YEARS OF STEAM SHOWER INNOVATION Installation Manual For Tutorials and Troubleshooting visit www thermasol com solutions TT7X XX ...

Страница 3: ...NG INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY IF YOU ARE FEELING UNCOMFORTABLE DIZZY FAINT OR STARTING TO FALL ASLEEP IMMEDIATELY EXIT THE STEAM ROOM DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT THERMASOL STEAM BATH GENERATORS ARE NOT DESIGNED TO BE USED FOR SPACE HEATING PURPOS...

Страница 4: ...UNDING WIRE ON THE BACK OF THE CONTROLLER PRIOR TO INSTALLTION OF YOUR THERMATOUCH LOCATE THE CLOSEST EARTH GROUND COPPER WATER PIPE AND ATTACHED THE WIRE AS SHOWN BELOW IF YOU HAVE ANY QUESITONS ABOUT THIS PROCESS PLEASE CONTACT US AT SUPPORT THERMASOL COM OR BY PHONE AT 800 776 0711 COPPER WATER PIPE EARTH GROUNDING WIRE GROUNDING STRAP Shower wall ...

Страница 5: ...3 7142 Materials needed ThermaTouch control M12 cable Silicone Power Distribution Module PDM Mud Ring Ethernet Cable with RJ 45 Connector not supplied Other materials as required Back of Control REMINDER in order to receive software updates the unit must be plugged into the internet using an Ethernet Cable connected to a Router Router and Ethernet Cable not supplied Power Data M12 connection Audio...

Страница 6: ...ibution Module PDM The other end of the cable runs to the back of the control in the shower location DO NOT pinch nail staple wedge or bind the data cable DO NOT wrap the data cable around steam line or route it in a manner so that the hot steam line could melt the cable Any damage to the control cable will result in the control not working properly Carefully connect the data cable to the PDM and ...

Страница 7: ...ol and see that it lights up Coat the entire groove on the control back with supplied waterproof silicone to fully seal the control to the wall Completely seal the control to the wall so moisture does not collect behind it Place the control on the wall pressing firmly You may need to tape the control into place until the silicone dries Be careful not to harm the wall or control with the tape Let d...

Страница 8: ...ng ThermaTouch to Generator 6b Connecting ThermaTouch to Serenity Light Sound Rainhead ThermaTouch Control Installation Instructions 7 THERMASOL COM I 800 776 0711 Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details ...

Страница 9: ...h Control Installation Instructions 8 THERMASOL COM I 800 776 0711 Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details TTC SLS 110v M12 Cable M12 Cable Audio Cable TTC SLS 110v M12 Cable M12 Cable Audio Cable M8 Cable ...

Страница 10: ...or copper tubing from unit to steamhead rough in fitting as permitted by code A B The steam line can run up and then down once or horizontal but never run down and then up If it does a steam trap will be produced at the low point blocking the flow of steam Insulate the steam outlet piping if the piping run exceeds 10 feet or is exposed to cold areas Use steam rated insulation Pitch angle steam lin...

Страница 11: ...t be done from backside of finshed space For new framing Mount and install rough in fitting to be flush with finished wall Connect a 1 2 NPT brass pipe or copper tubing to the steam outlet union not included on the generator running the pipe to the steam head location in the wall to connect with the steamhead rough in fitting It is very important that the pipe is firmly secured to the wall so that...

Страница 12: ...nt steamhead with facing up to allow aromatherapy well to dispense steam For detailed installation instructions of the steamhead please see Installation section in thermasol com customer support Apply a small amount of supplied lubricant directly on the o rings Once the shower wall is complete and the housing is sealed to the wall remove the protective cap and insert the steamhead into housing Use...

Страница 13: ...ons Click on Troubleshoot then click on ThermaTouch Control Error Codes ThermaTouch Control Installation Instructions 12 THERMASOL COM I 800 776 0711 Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details ...

Страница 14: ...81190_C 1958 STEAM WAY ROUND ROCK TX 78665 PHONE 800 776 0711 FAX 800 556 5257 WWW THERMASOL COM ...

Страница 15: ...Digital Shower Valve OVER 60 YEARS OF STEAM SHOWER INNOVATION Installation Manual TDS 3000 ...

Страница 16: ...R THERMASOL PRODUCT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH DO NOT USE THIS PRODUCT WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS AS THIS CAN BE HAZARDOUS TO YOUR HEALTH All products must be installed in accordance with installation instructions provided Failure to do so may invalidate warranty at manufacturer s discretion 2018 The...

Страница 17: ...ails 3 3 Typical System Layout Easy Start Control Outside Shower Water Inlets Hot Cold Shower Outputs 3 TDS 3000 Digital Shower Valve Digital Interface 110V Power 208 240VAC Steam Generator 110V Power Serenity Light and Sound TTC AUDIO OUT TTC INPUT SLS INPUT CONTROL 2 INPUT CONTROL 1 INPUT 24 VDC INPUT STEAM UNIT INPUT ThermaTouch Control Inside Shower To LAN ROUTER PDM ...

Страница 18: ... 2 For illustrative purposes only Consult with qualified professional for steam room construction details 4 4 Scope of Application IMPORTANT The Digital Shower Valve must be accessible and should not be sealed in the wall TDS 3000 Digital Shower Valve Digital Interface PDM ...

Страница 19: ...Digital Shower Valve THERMASOL COM I 800 776 0711 Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details Hot Water Cold Water ...

Страница 20: ...Digital Shower Valve THERMASOL COM I 800 776 0711 Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details Hot Water Cold Water ...

Страница 21: ...e purposes only Consult with qualified professional for steam room construction details 5 Remove Cover 6 Inside Valve System Controller 7 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 15V ACCU TLI Hot Mounting Holes Battery Compartment Power Supply Connector Block Cold Inlets Outlets ...

Страница 22: ...arnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details 8 7 Mark and Drill Holes 235mm 9 25 235mm 9 25 8mm 0 31 IMPORTANT The Digital Shower Valve must be installed within 50 of the PDM module ...

Страница 23: ...2 For illustrative purposes only Consult with qualified professional for steam room construction details 9 8 Install Valve System Controller 9 Remove Inlet Retaining Bolt 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X ...

Страница 24: ... 10 Connect Hot and Cold Water Supply 11 Remove Outlet Retaining Bolt 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 1 Connect hot and cold water supply 2 Insert inlet connectors 3 re insert retaining bolt 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X IMPORTANT Flush the pipework before connection 1 2 NPT Connections ...

Страница 25: ...ils 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 11 12 Connect Outlet Pipeworks 1 Connect outlet pipeworks 2 Insert outlet connectors 3 re insert retaining bolt IMPORTANT Flush the waterlines prior to connecting to clear any debris 1 2 3 1 3 2 1 2 NPT Connections ...

Страница 26: ... construction details 12 13 Connect Back Up Battery 14 Connect The Digital Interface 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X RS232 Port Connect the digital interface to the RS232 port Accu ...

Страница 27: ...Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details 13 15 Connect The PDM 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X ...

Страница 28: ...page 2 For illustrative purposes only Consult with qualified professional for steam room construction details 14 16 Re fit Cover and Connect 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X IMPORTANT Electrical connection must be installed by a qualified electrician ...

Страница 29: ...roduct at www thermasol com warranty so we can assist you much quicker if you ever need to contact our Technical Support Department In addition we ll keep you informed about your product and time to time we ll update you about new products and other company announcements Thank you from all of us at ThermaSol and we wish you many relaxing and steamy days ahead We will not sell rent or share your pe...

Страница 30: ...ects Limitations These warranties will be terminated by ThermaSol for the following reasons 1 ThermaSol will not be liable in any way for any indirect special incidental exemplary or consequential damages resulting from the sale delivery installation or use of its products Users are responsible for suitability of the products for their applica tion Damage resulting from improper specification or a...

Страница 31: ...Digital Shower Valve THERMASOL COM I 800 776 0711 Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details Notes 17 ...

Страница 32: ...Digital Shower Valve 1958 STEAM WAY ROUND ROCK TX 78665 PHONE 800 776 0711 FAX 800 556 5257 WWW THERMASOL COM 81216 Rev D ...

Страница 33: ...1958 STEAM WAY ROUND ROCK TX 78665 PHONE 800 776 0711 FAX 800 556 5257 WWW THERMASOL COM 81246_A ...

Отзывы: