background image

Please read and follow the installation and operation 

instructions carefully, to ensure the long life and reliable 

operation of this appliance.

CONTENTS

important Safety instructions

 ........................................................................................

3

Product Features

 ...................................................................................................................................

4

Product Structure

 .................................................................................................................................

4

technical data

............................................................................................................................................

5

installation Guideline

 ....................................................................................................................

5

installation Method

 ..........................................................................................................................

6

System diagrams

 ..................................................................................................................................

7

Maintenance

 .............................................................................................................................................

10

trouble-Shooting

 .............................................................................................................................

11

Attention!

This is not a do-it-yourself project. Failure to have this appliance installed by a licensed 
plumber and electrician will void all warranties.

Under no circumstances should you attempt to install, repair or disassemble the electric 
instantaneous water heater without first shutting off all power to the unit directly at the 
circuit breaker box.

Installation of this product is restricted to indoor locations only by licensed plumbing or 
electrical contractors.

Important Safety Instructions

1.  The installation must be installed in compliance with national Electrical regulations   
 

and your local electrical and plumbing codes.

2.  This appliance must be 

earthed

. (If the model is equipped with a plug, it is an  

 

 

electric leakage protection plug).

3.  Install or locate this water heater only in accordance with the provided installation    
 instructions. 

4.  Use this water heater only for its intended use as described in this manual.

5.  Contact a qualified electrician to have the unit properly installed for the models  

 

 

which are not equipped with a plug. 

6.  This appliance is not intended for use by persons (including children) with reduced   
 

physical sensory or mental capabilities, or lack of experience and knowledge, unless   

 

they have been given supervision or instruction concerning use of the appliance by  

 

a person responsible for their safety. Children should be supervised to ensure that    

 

they do not play with the appliance.

7.  This appliance 

must

 be permanently connected to the fixed circuit breaker and it    

 

must be installed vertically (excluding the models which are equipped with a plug).   

 

do Not

 install this appliance directly onto timber or in a strong magnetic field.

8.  This appliance 

must Not

 be switched on if you think it may be frozen, as this could  

 

result in serious damage to the unit. Wait until you are sure that the ThermaQ Midi    

 

has completely thawed out before you switch it on.

9.  Please test the outlet hot water temperature with your hand to make sure it is  

 

 

suitable for showering to avoid possible scalding or injury.

10.  Before connecting pipes to the water heater outlet and inlet hoses, it is extremely    
 

important to FLUSH the pipes to wash away all plumbing waste or residue that  

 

 

could be detrimental or damaging to the unit.

11.  If there is damage to the wiring, you must contact a qualified electrician to replace    
 

it with dedicated wire from our authorized dealers.

12.  A check valve is required to be installed at the water inlet.

13.  The water relief valve should work periodically to remove calcium carbonate  

 

 deposits.

14.  The drain-pipe which is connected to the water relief valve should be installed  

 

 

facing vertically downwards in a frostless environment. 

15.  The spray head must be descaled regularly.

Excellence in Hot Water Technology.

2

3

 

ThermaQ Specification Hotline 01924 270847

Содержание MIDI

Страница 1: ... 9ND t 01924 270847 f 01924 271310 sales ThermaQ co uk www ThermaQ co uk EXCELLENCE IN HOT WATER TECHNOLOGY ThermaQ endeavour to keep the content of this brochure as up to date as possible We reserve the right to make changes to all ThermaQ products and services at anytime To ensure you have the most current information please contact ThermaQ directly Follow us on twitter ThermaQ EXCELLENCE IN HOT...

Страница 2: ...duced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance 7 This appliance MUST be permanently connected to the fixed circuit breaker and it must be installed vertical...

Страница 3: ...e mains power supply incoming water pressure and the grounding conditions are adequate and the ammeter and wire are at the correct standard required for installation 3 The appliance must be properly grounded due to the dedicated branch circuits of high voltage within the unit Ground wires must be brought to the ground at the circuit breaker panel 4 This appliance MUST be permanently connected to t...

Страница 4: ...ersink module should always have the connections on the top of the unit Fig 1 Fig 2 Fixing unit to an external brick wall System 3 Incoming Cold Mains 5 Bar Or Above Additional Equipment Required 2L Portable Expansion Vessel Check Valve Pressure Reducing Valve HEATER Expansion Vessel Check Valve Closest Cold Draw Off Pressure Reducing Set Service Valve Not Supplied Discharge To Drain Pressure Reli...

Страница 5: ... isolated the electricity supply Plumbing Your new water heater s connections are 1 2 BSP fittings and these connections are clearly marked on the unit It is important that these two connections are not swapped over The connection from the heater to the system pipework should be made using flexible stainless steel hoses this facilitates the operation of the unit and also makes future maintenance e...

Страница 6: ...uble Shooting Excellence in Hot Water Technology 10 11 ThermaQ Specification Hotline 01924 270847 Problems Possible Causes Corrective Actions The pressure release valve is constantly discharging or dripping The incoming cold mains pressure is to high Please fit pressure reducing set in line with system 3 The pressure release valve drips or discharges whilst the unit is heating up There is insuffic...

Отзывы: