WATER CONNECTIONS

1.  All water pipework must comply with national regulations and local water piping codes.  

2.  No matter whether installing the appliance upright or upside down, please connect the    
 

inlet connection (blue nozzle on the unit) to the cold water inlet pipe; connect the outlet    

 

connection (red nozzle on the unit) to the hot water outlet pipe. 

3.  The unit should be connected directly to the mains water supply. Flush pipes first with  

 

 

water to remove any debris or loose particles.  

4.  It is required that one uses G1/2” water connections to fit the appliance. Please connect the  
 

inlet and outlet pipe in the correct order mentioned above.

5.  Please remember to install rubber seal O-rings at the connections. When all water  

 

 

connections are completed, check for leaks and take corrective action before proceeding    

 

to turn the unit on.  

ELECTRICAL CONNECTION

1.  All electrical work must comply with national regulations and local electrical codes

2.  The unit must be connected to a properly grounded dedicated branch circuit of  

 

 

proper voltage rating. 

3.  While feeding the cable to terminal blocks/circuit breaker, please make sure the  

 

 

metal wire ends and the terminal blocks touch and can be sealed completely. Then   

 

tighten the screws up to make sure the full current can go through.

9

 

ThermaQ Specification Hotline 01924 270847

Inlet

Outlet

Fig 6.

 Fix the 

application on 
the wall.

Fig 7.

 Connect 

the correct water 
pipes to the water 
inlet and water 
outlet connections, 
remembering 
to install rubber 
O-rings to ensure a 
watertight seal.

Cont.

2890/ElectricPackagingManuals/A5.indd   9

08/10/2018   10:56

Содержание ELITE 11

Страница 1: ...ThermaQ endeavour to keep the content of this brochure as up to date as possible We reserve the right to make changes to all ThermaQ products and services at anytime To ensure you have the most current information please contact ThermaQ directly Follow us on twitter ThermaQ EXCELLENCE IN HOT WATER TECHNOLOGY 2890 ElectricPackagingManuals A5 indd 12 08 10 2018 10 56 ...

Страница 2: ...Elite Touch for single or multi point applications where an unvented storage solution is required E L I T E TOUCH EXCELLENCE IN HOT WATER TECHNOLOGY 2890 ElectricPackagingManuals A5 indd 1 08 10 2018 10 56 ...

Страница 3: ... Shooting 11 Attention This is not a do it yourself project Failure to have this appliance installed by a licensed plumber and electrician will void all warranties Under no circumstances should you attempt to install repair or disassemble the electric instantaneous water heater without first shutting off all power to the unit directly at the circuit breaker box Installation of this product is rest...

Страница 4: ...nce 7 This appliance MUST be permanently connected to the fixed circuit breaker and it must be installed vertically DO NOT install this appliance directly onto timber or in a strong magnetic field 8 This appliance MUST NOT be switched on if you think it may be frozen as this could result in serious damage to the unit Wait until you are sure that the ThermaQ Elite Touch has completely thawed out be...

Страница 5: ...reaches over 62 C the electricity will be cut off to avoid getting scalded and the screen displays E1 The appliance will start to work automatically when temperature drops to the desired set temperature 4 Malfunction of sensor when there is a malfunction with the temperature sensor the heater stops working and displays E3 5 Dry heating thermal cut off When the heating temperature is over 95 C the ...

Страница 6: ...T CODE EWH0010 EWH0011 EWH0012 POWER 7 5kW 9kW 11kW FLOW RATE UPTO 6L MIN 8L MIN 10L MIN RATED CURRENT 32 7A 39 2A 47 9A BODY MATERIAL STAINLESS STEEL SAFETY CLASS IP25 TEMP SETTING RANGE 30 C 55 C VOLTAGE 220 240V RECOMMENDED CABLE SIZE 10 0mm2 OVERHEAT PROTECTION 62 C THERMAL CUT OUT 95 C CONTROL MODE TOUCH SCREEN CONTROLS WORKING PRESSURE 6 bar WATER CONNECTIONS G1 2 DIMENSIONS 360 x 220 x 90 2...

Страница 7: ...ted branch circuits of high voltage within the unit Ground wires must be brought to the ground at the circuit breaker panel 4 This appliance MUST be permanently connected to the fixed circuit breaker If you don t use the heater please switch off the circuit breaker 5 Do NOT install this appliance on timber or in the presence of a strong magnetic field The appliance can be installed above or under ...

Страница 8: ...Fig 2 Remove screw which fixed the front and back case Fig 3 Open the front case then connect power cable to the terminal blocks with L1 L2 and E in pointed position 7 ThermaQ Specification Hotline 01924 270847 L2 L1 E Fig 1 Front and back of the appliance 2890 ElectricPackagingManuals A5 indd 7 08 10 2018 10 56 ...

Страница 9: ...marks for punching then drill 3 holes with 6mm diameter and consequently insert screws into the wall Excellence in Hot Water Technology 8 124mm 1 2 3 4 320mm Position the paper template where you wish to place the unit Make a raw plug hole in the wall by means of a drill Fix the hangers to the wall Fix the unit to the hangers 3 2 6 m m 2890 ElectricPackagingManuals A5 indd 8 08 10 2018 10 56 ...

Страница 10: ...the connections When all water connections are completed check for leaks and take corrective action before proceeding to turn the unit on ELECTRICAL CONNECTION 1 All electrical work must comply with national regulations and local electrical codes 2 The unit must be connected to a properly grounded dedicated branch circuit of proper voltage rating 3 While feeding the cable to terminal blocks circui...

Страница 11: ... temperature Temperature setting range is 30 55 C If the unit has been paused you may initially get a short burst of very hot water while you turn it on again Please run the water through for a few seconds to let the temperature settle down Please check hot water with your hand before taking a shower or using water on other parts of the body If the unit will not be used in winter drain out water c...

Страница 12: ...VE ACTIONS Inlet and outlet fittings leaking Fittings not tight Rubber washer worn out Tighten fittings Change rubber washer LED no signal Power not connected LED Damaged Connect power to the unit Change LED Functional keys not working No water out from shower Water pressure too low Key or PCB damaged Open valve to get water Open valve to get pressure Change key or PCB Water too hot Too high tempe...

Отзывы: