5
TMT-HA600 Hot Air Tool
USER MANUAL
SYSTEM SETTINGS
System Settings - Enter Menu
The system settings menu can be accessed by following the procedure below:
1. Turn off unit.
2. Ensure that the (e) Function Button is in the "on" position (pushed down).
3. Switch the power switch on the back of the unit to the “on” position.
4. While the letters “ESD SAFE” are scrolling across the display, simultaneously press and hold both (c)
Temperature Control up and down buttons (see Front Panel).
5. If successful the digital display will show “SEL 1” (Select 1).
Selection Menu
Function
1
Hot Air Gun Sleep Timer
2
Temperature Scale Adjustment
3
AC Line Frequency Selection
4
Hot Air Gun Temperature Calibration
System Settings - Hot Air Gun Sleep Timer
Once the hot air gun is placed into the holder. The system will go into sleep mode once the sleep timer has been
reached (default is 5 minutes). Use the following procedure to set the sleep timer:
1. Follow System Settings - Enter Menu procedures.
2. Use the (d) Air Flow Control down button to adjust system selection menu to SEL 1.
3. Press the (d) Air Flow Control up button to confirm the selection.
4. The display will show “t" (timer) and x (x = minutes). The sleep timer is adjustable from 5 to 60 minutes with "off"
representing the auto-sleep mode is turned off.
5. Press the (d) Air Flow Control up and down buttons to adjust the sleep timer.
6. To save the selected settings and exit from the menu press the (e) Function Button.
System Settings - Temperature Scale Adjustment
By default, the temperature scale has been set by the factory. For manual override follow the procedure below:
1. Follow System Settings - Enter Menu procedures.
2. Use the (d) Air Flow Control down button to adjust system selection menu to SEL 2.
3. Press the (d) Air Flow Control up button to confirm the selection.
4. The display will show "c" (celsius) or "f" (fahrenheit).
5. Press the (d) Air Flow Control up and down buttons to adjust the temperature scale.
6. To save the selected settings and exit from the menu press the (e) Function Button.
System Settings - AC Line Frequency Selection
By default, the line frequency has been set by the factory. For manual override follow the procedure below:
1. Follow System Settings - Enter Menu procedures.
2. Use the (d) Air Flow Control down button to adjust system selection menu to SEL 3.
3. Press the (d) Air Flow Control up button to confirm the selection.
4. The display will show "-50" (50 Hz) or "-60" (60 Hz).
5. Press the (d) Air Flow Control up and down buttons to adjust the AC Line Frequency.
6. To save the selected settings and exit from the menu press the (e) Function Button.
System Settings - Hot Air Gun Temperature Calibration
By default, the temperature calibration has been set by the factory. For manual override follow the procedure below:
1. Follow System Settings - Enter Menu procedures.
2. Use the (d) Air Flow Control down button to adjust system selection menu to SEL 4.
3. Press the (d) Air Flow Control up button to confirm the selection.
4. The display will show "Add XXX" or "Sub XXX". (Add = add offset, Sub = subtract offset, XXX = temp. offset)
5. Press the (d) Air Flow Control up and down buttons to adjust the temperature offset.
6. To save the selected settings and exit from the menu press the (e) Function Button.
Содержание TMT-HA600 Series
Страница 1: ...USER MANUAL TMT HA600 HOT AIR TOOL www thermaltronics com ...
Страница 2: ......
Страница 11: ...Support Email support thermaltronics com www thermaltronics com ...