background image

3

TMT-HA050-2 Hot Air Tool

USER MANUAL

UNPACKING/ASSEMBLY/OPERATION

Please read this manual and follow the directions before using the equipment. The carton contains:

1. TMT-HA050-2 Hot Air Tool

2. HTN-D30, HTN-D50, HTN-D80, HTN-D100 nozzles
3. Power Cord

Important: Keep all shipping materials until satisfactory operation has been verified.

Assembly and Operation

1. Remove TMT-HA050-2 Hot Air Tool from its box and place on a suitable work bench.

2. Select the proper nozzle and secure it to the handle.

3. Connect the AC plug to a suitable AC power outlet.

4. Switch the air pump power switch to the “on” position

5. Switch the heater power switch to the "on" position

6. Adjust the air flow and temperature. 

7. Wait for the actual temperature to reach the set temperature. The unit should then be ready.

Power Off

1. Increase the air flow to max (99)

2. Decrease the temperature to the lowest setting

3. Wait until the temperature of the heater has cooled down.

4. Switch off the unit, unplug if not used for extended periods of time.

Replacing the Heating Element

Caution: Disconnect power before replacing heater element.

1. Remove the six screws holding the hot air tool together and open the cover.
2. Remove the three screws on the heater PCBA.
3. Disconnect the heater by pressing on the connector lock.
4. Carefully insert a new heating element (HA-HE050-2).
5. Reassemble the hot air gun in the reverse order it was disassembled.

1

3

1

2

Содержание TMT-HA050-2

Страница 1: ...USER MANUAL TMT HA050 2 HOT AIR TOOL www thermaltronics com ...

Страница 2: ......

Страница 3: ...epair or replace it free of charge at its sole option Warranty period is from the date of purchase by the original owner If the date of purchase cannot be substantiated the date of manufacture will be used as the start of the warranty period TABLE OF CONTENTS TMT HA050 2 SPECIFICATIONS 1 INTRODUCTION 1 SYSTEM FEATURES 1 SAFETY PRECAUTIONS 2 CONTROL PANEL 2 UNPACKING ASSEMBLY OPERATION 3 ORDERING G...

Страница 4: ...ested and inspected by Thermaltronics prior to shipment and with proper maintenance will give you years of reliable performance SYSTEM FEATURES The TMT HA050 2 hot air tool can be used for surface mount component removal and reflow on components such as SOIC CHIP QFP PLCC and others 1 Digital display shows temperature and air flow 2 Light portable plug and use tool 3 Convection heating allows low ...

Страница 5: ...ent in a well ventilated area away from combustible equipment 2 Disconnect the power cord if the unit is not used for an extended period of time 3 Place handle in stand when not in use 4 Handle with care Never drop or sharply jolt the unit The unit contains delicate parts that can be damaged if subjected to physical force Do not spill any liquids into the unit 5 Do not operate on uneven surfaces 6...

Страница 6: ...5 Switch the heater power switch to the on position 6 Adjust the air flow and temperature 7 Wait for the actual temperature to reach the set temperature The unit should then be ready Power Off 1 Increase the air flow to max 99 2 Decrease the temperature to the lowest setting 3 Wait until the temperature of the heater has cooled down 4 Switch off the unit unplug if not used for extended periods of ...

Страница 7: ...L24 Nozzle 10 6mm x 15 9mm SOL 24 24J 10 6 15 9 HTN SL28 Nozzle 10 6mm x 18 4mm SOL 28 10 6 18 4 HTN SL44 Nozzle 16 0mm x 27 9mm SOL 44 16 0 27 9 HTN SJ32 Nozzle 13 5mm x 20 6mm SOJ 32 13 5 20 6 HTN SJ40 Nozzle 13 5mm x 25 4mm SOJ 40 13 5 25 4 HTN TS24 Nozzle 17 0mm x 7 1mm TSOP 20 24 PIN 17 0 7 1 HTN TS32 Nozzle 21 0mm x 9 1mm TSOP 28 32 PIN 21 0 9 1 HTN TS40 Nozzle 21 0mm x 10 8 TSOP 40 PIN 21 0...

Отзывы: