T R 2 R X
C a b l e M a n a g e m e n t
5 5 0 W
T R 2 R X
C a b l e M a n a g e m e n t
5 5 0 W
ATX 12V 2.2 Version
ATX 12V 2.2 Version
Thermaltake TR2 Power Supply
Thermaltake TR2 Power Supply
4.4 Protection:
If the power supply protection that latch off all main outputs. ( when
OCP, OVP or short protection is working ).Reset by cycling remote
on/off control or AC power.+5Vsb is recovery.
4.4.1 Over Current Protection
+5V & +3.3V Not over 240VA for every output voltage
+12V1 & +12V2 26A~32A
4.4.2 Over Voltage Protection
+3.3V output 4.5 Vmax
+5.0V output 7.0 Vmax
+12.0V output 15.6 Vmax
4.4.3 Short Protection
All outputs to GND.
4.5 Environment:
4.5.1 Operating Temp. 0 C to +40 C
4.5.2 Storage Temp. -20 C to +70 C
4.5.3 Operating Humidity 20% to 90%, non-condensing
4.5.4 Storage Humidity 5% to 95%, non-condensing
4.5.5 Operating Altitude 0 to 10,000 feet
4.5.6 Storage Altitude 0 to 50,000 feet
4.7 EMI & Safety
4.7.1 Conducted EMI
1. Meet FCC: Class B
2. Meet CISPR 22: Class B
3. Meet VCCI: Class B
4.7.2 Safety Standards
1. Meet UL/CUL (UL 60950)
2. Meet TUV EN60950
3. Meet CB (
)
4. Meet CE
5. HARMONIC (IEC61000-3-2 CLASS D)
IEC 60950
4.6 Hi-Pot: (Input/Output isolation)
4.6.1 Primary to Secondary
3535Vdc for
4.6.2 Insulation Resistance
Primary to earth ground 500Vdc, 50M ohms Min.