Preface 

Thank you for purchasing this Thermalec

®

 Pool Heater. 

Thermalec®

 

electric  Pool  and  Spa  heaters  are  designed  for  the  heating  of  water  for 

swimming pools and spas. It is manufactured in the United Kingdom by Thermalec® Pool 
& Spa Products and marketed worldwide. 

 Established  nearly  50  years  ago,  Thermalec®  is  renowned  in  the  United  Kingdom  and 
overseas  as  one  of  the  foremost  names  as  manufacturers  of  high  quality  products  for 
swimming pools and spas. Thermalec Pool and Spa Products is historically best known for 
its  premium  electric  pool  heaters,  but  latterly  has  expanded  its  range  of  products  for 
pools  and  spas  to  bring  novel  and  high  quality  equipment  to  the  international  pool 
market. 

Thermalec Pool & Spa Products is a member of Meddings Thermalec Ltd. 

We  hope  that  you  will  be  more  than  satisfied  with  your  Thermalec®  pool  heater.  At 
Thermalec,  we  always  welcome  customer  feedback.  Should  you  have  any  comments  or 
suggestions regarding this equipment, please do not hesitate to contact us. 

Thermalec® pool heaters are built to the highest standards using quality components and 
materials. Should you have any queries or experience any problems, please contact your 
local reseller or contact us directly. We are here to help. 

In  the  following  pages  you  will  find  information  on  the  installation,  operation  and 
maintenance  of  your  Thermalec®  pool  heater.  Please  read  through  the  whole  manual 
carefully  and  thoroughly  before  attempting  to  install  or  operate  this  equipment

it 

contains information important for a safe, efficient and long service life of the heater

In  the  event  of  any  questions  or  queries  regarding  the  installation,  operation  and 
maintenance of this heater, please do not hesitate to contact us. 

 

 

Kingsley Close, East Way, Lee Mill Industrial Estate, Ivybridge, Devon, PL21 9LL United Kingdom 
Telephone: +44 (0) 1752 313343  Fax: +44 (0) 1752 313353 
Email:    

[email protected]

 

Website: 

www.thermalec.co.uk

 

Twitter   

twitter@thermalec 

 

 

Содержание ZENITH ZHR 96

Страница 1: ...l Heater ZENITH RANGE 96kW 120kW 144kW 168kW Meddings Thermalec Ltd Kingsley Close East Way Lee Mill Industrial Estate Ivybridge Devon PL21 9LL United Kingdom Tel 01752 313343 Fax 01752 313353 sales t...

Страница 2: ...on 10 Positioning the heater on the flowsheet 10 Positioning and piping connection of the heater 11 Direction of flow through the heater 12 Electrical Installation 12 3 OPERATION 15 Commissioning 16 F...

Страница 3: ...rmalec we always welcome customer feedback Should you have any comments or suggestions regarding this equipment please do not hesitate to contact us Thermalec pool heaters are built to the highest sta...

Страница 4: ...res of the Thermalec Zenith ZHR Pool Heater 2 Figure 2 Sectional model of a typical Thermalec Pool Heater 3 Figure 3 Suggested heater position on plant room flowsheet 10 Figure 4 Water connection on a...

Страница 5: ...ited actions or procedures WARNING or INSTRUCTION Warning of danger General warning that special attention should be paid Important instruction that must be followed WARNING Voltage or high voltage Ri...

Страница 6: ...Zenith Range Instruction Manual Page v...

Страница 7: ...Zenith Range Instruction Manual Page 1 1 GENERAL...

Страница 8: ...s of the Thermalec Zenith Pool Heater KEY Electrical control gear enclosure Drain valve Circuit breakers on front fascia Support foot Control panel on front fascia Water inlet default Water outlet def...

Страница 9: ...Y Electrical control gear enclosure Inlet baffle plate uPVC element holding plate Temperature pocket Outlet baffle plate Water inlet overflow weir Water outlet nozzle default Water inlet port default...

Страница 10: ...The heating elements are suspended inside the vessel from the thick uPVC element holding plate that covers the top of the vessel and from which the removable baffles are also suspended The heating el...

Страница 11: ...n switched on followed by the circuit breakers on the heater A red indicator shows that the heater is powered An amber light on the heater indicates that the filter pump is in operation If the pump do...

Страница 12: ...ater flowrate ranges Zenith Heater Installed power 96 kW 120 kW 144 kW 168 kW Maximum hard water l min 700 700 700 700 Maximum soft water l min 350 350 350 350 Minimum l min 160 200 240 280 Control an...

Страница 13: ...owered X 1 Red EHOT Electrical data Protection level IP 21 Fuses 2 x 2 Amp Pump interlock voltage 230 V AC Element heat flux 11 5 W cm2 max Standard Power Supply 400V 3ph 50Hz Model Ref Load kW Curren...

Страница 14: ...Zenith Range Instruction Manual Page 8 2 INSTALLATION...

Страница 15: ...These are designed such that in May of an average year in North western Europe an outdoor pool that is heated during the off peak power supply period of seven hours a day will take about five nights...

Страница 16: ...g diagram illustrates a suggested plant flowsheet showing the positioning of the heater with respect to the other plant room process units Chemical dosing systems should not be installed adjacent to t...

Страница 17: ...point of a pipework system Water may drain from the heater causing damage to it The pipework must be designed such that the heater is always full of water The heater must always be installed horizonta...

Страница 18: ...itch heater circuit breakers to OFF b Switch main power supply and pump interlock supply to OFF c Remove main cover d Reverse the two probes The controller probe is situated at the left hand end of th...

Страница 19: ...led firmly down onto the incoming cable ends Make sure that the cable is of sufficient diameter to ensure a good clamp is made and if required wind a length of copper strand around the other strands t...

Страница 20: ...Zenith Range Instruction Manual Page 14 Figure 4 Drg APH 13 19 Heater filter pump interlock...

Страница 21: ...Zenith Range Instruction Manual Page 15 3 OPERATION...

Страница 22: ...ve flow of water into pool Amber pump supply lamp ON j Switch main power supply to ON Red mains power supply light is ON k Remove seal from heater circuit breakers and switch ON Red and Amber heater s...

Страница 23: ...00 gal hr 350 l min Minimum 1920 gal hr 160 l min 2400 gal hr 200 l min 2880 gal hr 240 l min 3360 gal hr 280 l min Calculation of the water flowrate To calculate the exact flowrate of water flowing t...

Страница 24: ...consideration should be given to opening the vessel to remove debris If the pool is to be kept in a semi operational condition during the winter then the heater may only be left full of water if the f...

Страница 25: ...t lf so reset and wait if thermostat trips again check for sufficient water flow and air in system lf trip is not associated with this check individual heating elements for insulation resistance Prote...

Страница 26: ...xing of the warm water from the heater with the cooler water in the pool leading to a layer of warmer water forming at the height of the inlets To cure this aim the direction of the pool inlet jet dow...