950-0265revC - 19 - November 30, 2020
TECHNICAL SPECIFICATIONS
9,000 and 12,000 BTU Units (115V)
(Thermal Zone - Sea Breeze) Indoor / Outdoor
244-1501-E, 244-1501-C
9H49YIMI, 9H49YOMI
244-1502-E, 244-1502-C
12H49YIMI, 12H49YOMI
AHRI Reference Number (Sea Breeze / Thermal Zone)
202576832 / 202576833
202576826 / 202576827
Power supply
Ph-V-Hz
115V, 1Ph, 60Hz
115V, 1Ph, 60Hz
Cooling
Capacity
Btu/h
9000
12000
Input
W
782
1020
Rated current
A
6.8
8.87
EER
Btu/w
11.5
10.5
SEER
Btu/w
19
19
Heating
Capacity
Btu/h
10000
12000
Input
W
925
1026
Rated current
A
8.1
8.93
COP
W/W
3.11
3.43
HSPF (region IV)
Btu/w
10
9.5
MINIMUM CIRCUIT AMPACITY
A
15
15
MAX.FUSE
A
15
15
Compressor
Model
KSK103D33UEZ3
KSK103D33UEZ3
Type
Rotary
Rotary
Brand
GMCC
GMCC
Capacity
W
3100
3100
Input
W
790
790
Rated current (RLA)
A
11.5
6.8
Heating Belt
Yes
Yes
Refrigerant oil/oil charge
ml
ESTER OIL VG74 310 ± 15 ml
ESTER OIL VG74 310 ± 15 ml
Indoor fan motor
Model
ZKFP-20-8-113
ZKFP-20-8-113
Brand
Welling
Welling
Input
W
35.2
35.2
Output
W
20
20
RLA
A
0.25
0.25
Speed (Hi/Mi/Lo)
r/min
1050/850/600
1100/850/750
Indoor air flow (Hi/Mi/Lo)
CFM
247/182/129
294/212/171
Indoor noise level (Hi/Mi/Lo)
dB(A)
38/32/25
38/30/28
Indoor unit
Dimension(W*D*H)
inch
28.43x7.36x11.42
31.57x7.44x11.69
Packing (W*D*H)
inch
31.10x10.63x14.76
34.45x11.22x14.76
Net/Gross weight
lbs.
17.2/22.7
18.96/24.91
Outdoor fan motor
Model
ZKFN-34-8-1-3
ZKFN-34-8-1-3
Input
W
58
58
Output
W
34
34
RLA
A
0.4
0.4
Winding Resistance
Ω
77.3
77.3
Speed
r/min
850/650
800/650
Outdoor air flow
CFM
1176.47
1176.47
Outdoor noise level
dB(A)
52
55
Outdoor unit
Dimension(W*D*H)
inch
30.31x11.81x21.85
31.50x13.11x21.81
Packing (W*D*H)
inch
35.43x13.58x23.43
36.22x15.35x24.21
Net/Gross weight
lbs.
66.8/71.87
70.33/76.28
Refrigerant type
g
R410A/850
R410A/840
Refrigerant type
oz
R410A/30
R410A/29.63
Refrigerant pre-charge
ft
25
25
Additional charge for each ft
oz
0.161
0.161
Design pressure
PSIG
550/340
550/340
Refrigerant piping
Liquid side/ Gas side
inch
1/4"
/
3/8"
1/4"
/
1/2"
Max. refrigerant pipe length
ft
82
82
Max. difference in level
ft
33
33
Wire Size / No. of Conductors
14 AWG / 4C (Recommended)
14 AWG / 4C (Recommended)
Electrical Shock Protection
I
I
Thermostat type
Remote Control
Remote Control
Wall Control (Optional)
YES
YES
Indoor selection range
- remote
Indoor (cooling/ heating)
℉
62
~
90/32
~
86
62
~
90/32
~
86
Outdoor unit operating
temperature range
Outdoor (cooling/heating)
℉
5
~
122/5
~
86
5
~
122/5
~
86
Application area (cooling standard)
sq.ft
129-189
172-252