![Thermal Dynamics SL100 HAND TORCH Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/thermal-dynamics/sl100-hand-torch/sl100-hand-torch_instruction-manual_1103325023.webp)
Manual 0-2962
3-3
INSTALLATION
3. Secure the Through - Hole protector with the re-
taining nut removed earlier.
4. Connect the torch leads or ATC Adapter Negative
/ Plasma Lead to the bulkhead connection inside
the Power Supply as shown.
Adapter
Plug
Pilot Lead
Torch Leads
Assembly or
ATC Adapter
Negative/Plasma
Lead
Adapter
Connector
Pilot Lead Stud
Negative/Plasma Lead
Connection
A-03527
Control Circuit
Connectors
Note: Actual Bulkhead
configuration may
differ from that shown.
Bulkhead Connections - ATC Adapter or Hand
Torch Leads with O2B Fittings
5. The Leads or ATC Adapter Assembly includes two
wires joined with mating connectors and covered
with an insulating sleeve. These wires must re-
main joined and insulated. Connect the remain-
ing torch leads connectors to the mating connec-
tors on the Power Supply Adapter.
6. Remove the top nut and washer from the Pilot
Stud.
7. Connect the pilot lead terminal to the stud and
secure with the nut and washer removed in the
above Step.
8. Tighten the Through - Hole protector onto the
Torch Leads or ATC Adapter Leads Assembly.
9.
For torches with the ATC Connector
, align the
torch leads male connector with the ATC female
receptacle. Push the male connector into the fe-
male receptacle. The connectors should push to-
gether with a very small amount of pressure. Se-
cure the connection by turning the locking nut
clockwise until it stops. DO NOT use the locking
nut to pull the connection together. Do not use
tools to secure the connection.
A-03627
1
2
ATC Male
Connector
ATC Adapter
Female Receptacle
Torch Leads
To
Power Supply
Torch Connection - Torch Leads with ATC Male
Connector, Power Supply with ATC Adapter
1
2
Control Cable
Connector (Machine
Torches Only)
ATC Male
Connector
ATC Female Receptacle
(Panel Mounted)
A-03602
Torch Connection - Torch Leads with ATC Male
Connector, Power Supply with Panel-Mounted ATC
Receptacle
10. Check the torch for proper consumable parts.
CAUTION
The torch parts must correspond with the type of
operation. Refer to Section 4.04, Torch Parts Se-
lection.
Содержание SL100 HAND TORCH
Страница 4: ......
Страница 10: ...GENERAL INFORMATION 1 6 Manual 0 2962...
Страница 16: ...GENERAL INFORMATION 1 6 Manual 0 2962...
Страница 38: ...OPERATION 4 10 Manual 0 2962...
Страница 44: ...SERVICE 5 6 Manual 0 2962...
Страница 62: ...APPENDIX A 2 Manual 0 2962 This page intentionally blank...
Страница 90: ...APPENDIX A 30 Manual 0 2962...