Replace the FET/Heatsink Assembly if any of the
above tests are open or shorted.
5. FET Output Clamp Diodes Check
Use an ohmmeter to check the resistance of the out-
put clamp diodes, (+ out) E17 and (- out) E18, per the
following procedure:
NOTE
The wires on E16 and E18 should still be discon-
nected from both FET/Heatsink Assemblies.
a. Place the meter (+) lead on E17 and the meter (-)
lead on E18 of the FET/Heatsink Assembly to
check the output clamp diode resistance. The
meter should indicate >1 meg ohms.
b. Place the meter (+) lead on E18 and the meter (-)
lead on E17 of the FET/Heatsink Assembly to
check the output clamp diode resistance. The
meter should indicate >1 meg ohms.
Replace the FET/Heatsink Assembly if any of the
above tests are open or shorted.
Содержание PakMaster 50 XL Plus
Страница 1: ...Manual No 0 2745 August 12 1999 Service Manual A 02464 Air Plasma Cutting Power Supply...
Страница 3: ...Record Serial Numbers For Warranty Purposes...
Страница 4: ......
Страница 16: ...SECTION 2 INTRODUCTION 10 Manual 0 2745...
Страница 34: ...SECTION 4 SERVICE TROUBLESHOOTING 28 Manual 0 2745...
Страница 44: ...SECTION 5 REPLACEMENT PROCEDURES 38 Manual 0 2745...
Страница 72: ...APPENDIX 66 Manual 0 2745 APPENDIX XI SYSTEM SCHEMATIC A 02503 9 13 16 J21 J20 J19 GAS SOL GAS INRUSH INRUSH...
Страница 73: ...Manual 0 2745 67 APPENDIX A 02503 OK OK TO MOVE 8 11 99...
Страница 74: ...APPENDIX 68 Manual 0 2745...