5.01 General Maintenance

O-rings on the Torch require lubrication on a regular
basis, depending on how frequently the torch shield
cup is disconnected and re-connected.  This will allow
the o-rings to remain pliable and provide a proper seal.
The o-rings will dry out, becoming hard and cracked,
if the o-ring lubricant is not used on a regular basis.
This can lead to potential performance problems.

Remove and apply a very light film of o-ring lubricant
(Catalog # 8-4025) to the o-rings on a weekly basis.

NOTE

DO NOT

 use other lubricants or grease on the torch

o-rings.  They may not be designed to operate within
high temperatures or may contain “unknown ele-
ments” that may react with the atmosphere.  This
reaction can leave contaminants inside the torch.
Either of these conditions can lead to inconsistent
performance or poor parts life.

Lower O-Ring
Cat. #8-3486

Upper O-Ring 
in Correct Groove
Cat. #8-3487

Upper Groove 
with Vent Holes 
Must Remain Open

Threads

Art # A-04394

5.02 Basic Troubleshooting  Guide

  WARNING

There are extremely dangerous voltage and power
levels present inside this unit.  Do not attempt to
diagnose or repair unless you have had training in
power electronics measurement and troubleshoot-
ing techniques.

1. Basic Troubleshooting,  Overview

This guide covers basic troubleshooting.  It is helpful for
solving many of the common problems that can arise with
this system.  If major complex subassemblies are faulty,
the unit must be returned to an authorized service center
for repair.

Follow all instructions as listed and complete each sec-
tion in the order presented.

2. Common Symptoms

A. Primary power switch is ON, but power indicator

doesn’t light.

1. Improper electrical connection.

a. Check the input cable line & connection.

b. Check the input power that it is turned on.

c. Check the input power fuse.

2. System was overloaded.

a. Turn Primary Power Switch Off and then On

again.

3. Switch may be faulty.

a. Return to an authorized service center for re-

pair.

4. Fuse may be faulty.

a. Check and replace power supply input fuse as

needed

B. Primary power switch is on, but the cooling fan

does not work.

1. No power / incorrect power to fan or failed fan.

a. Return to an authorized service center for re-

pair.

C. No air flow at torch when air check switch is turned

on.

1. Input air connection is disconnected.

a. Connect the input air.

2. Input air supply not working.

a. Check the manufacturers manuals for trouble

shooting or local maintenance procedures.

3. Internal connection is disconnected or loose.

a. Check all air line connections and fittings.

4. Filter or control PCB faulty.

a. Return to an authorized service center for re-

pair.

Содержание CUTSKILL C-100A

Страница 1: ...PLASMA 100 400 v 230 460 CUTSKILL Operation Manual C 100A PLASMA CUTTING SYSTEM Rev AA 01 Issue Date March 26 2007 Manual 0 4686 Operating Features...

Страница 2: ......

Страница 3: ...005 2006 2007 by Thermal Dynamics Corporation All rights reserved Reproduction of this work in whole or in part without written permission of the publisher is prohibited The publisher does not assume...

Страница 4: ......

Страница 5: ...2 2 2 05 System Contents 2 3 2 06 Transporting Methods 2 3 SECTION 3 INSTALLATION 3 1 3 01 Site Selection 3 1 3 02 Electrical Input Connections 3 1 3 03 Compressed Air Connection 3 3 3 04 Torch 3 3 S...

Страница 6: ......

Страница 7: ...head out of the welding fume plume Use an air supplied respirator if ventilation is not adequate to remove all fumes and gases The kinds of fumes and gases from the plasma arc depend on the kind of m...

Страница 8: ...this manual PLASMA ARC RAYS Plasma Arc Rays can injure your eyes and burn your skin The plasma arc process produces very bright ultra violet and infra red light These arc rays will damage your eyes a...

Страница 9: ...re Protection Association Batterymarch Park Quincy MA 02269 11 CGA Pamphlet P 1 SAFE HANDLING OF COM PRESSED GASES IN CYLINDERS obtainable from the Compressed Gas Association 1235 Jefferson Davis High...

Страница 10: ...UL Underwriters Laboratory rating 94VO flammability testing for all printed circuit boards used CENELEC EN50199 EMC Product Standard for Arc Welding Equipment ISO IEC 60974 1 BS 638 PT10 EN 60 974 1 E...

Страница 11: ...le Parts such as tips electrodes shield cups o rings starter cartridges gas distributors fuses filters 2 Equipment that has been modified by an unauthorized party improperly installed improperly opera...

Страница 12: ...GENERAL INFORMATION 1 6 Manual 0 4686 This Page Left Blank...

Страница 13: ...e 48 25 Amps 22 20 kVa Input Fuse 230V 10 1Phase Input Fuse 230V 10 3Phase 50 Amp Slow Blow 30 Amp Slow Blow Input Fuse 400V 10 32 Amp Slow Blow Input Fuse 460V 10 1Phase Input Fuse 460V 10 3Phase 30...

Страница 14: ...30 mm and 1 1 2 40 mm for maximum cut ABLILITY TO CUT UNPREPARED MATERIALS Pilot Arc ignition allows the 100A to cut painted coated or even rusted materials EXTENDED PARTS LIFE Consumable parts life i...

Страница 15: ...s 400V Non CE 1 1600 3 and 400V CE 1 1600 4 2 Meter Cord With No Plug 1 2 06 Transporting Methods Lift unit using the two lifting eyes on the top of the case Use hand cart or similar device of adequat...

Страница 16: ...Introduction 2 4 Manual 0 4686 This Page Left Blank...

Страница 17: ...0 3 phase 50 60 Hz Input Power CAUTION Check your power source for correct voltage be fore plugging in or connecting the unit The primary power source fuse and any extension cords used must conform to...

Страница 18: ...e r g a d e E n t r a d a Monof sico 1 alambre Art A 04697 Black White Red 1 Phase 3 Wire I n p u t P o w e r Art A 04652 Black White Red 3 Phase I n p u t P o w e r 5 Provide a small amount of slack...

Страница 19: ...ble is connected properly through the front panel and the clamp to clean work surface Before activating turn torch away from yourself and others DANGER Do not cut in humid or wet surroundings Before y...

Страница 20: ...Installation 3 4 Manual 0 4686 This Page Left Blank...

Страница 21: ...o operate the torch Torch Latch Switch Indicator This indicator lights when the Torch Latch Switch has been pressed for continuous cut ting B Switches Torch Latch Switch For continuous cutting perform...

Страница 22: ...ust correspond with the type of operation and with the amperage output of this Power Supply 100 amps maximum Use only genuine manufactured parts with this torch Electrode 9 8215 Start Cartridge 9 8213...

Страница 23: ...ld steel with output current at the highest setting Unit Standoff Material Thickness C 100A 3 16 5mm 1 2 12mm 52 1308 42 1047 C 100A 3 16 5mm 1 2 12mm 58 1448 46 1159 C 100A 3 16 5mm 3 4 19mm 25 633 2...

Страница 24: ...Operation 4 4 Manual 0 4686 This Page Left Blank...

Страница 25: ...t and troubleshoot ing techniques 1 Basic Troubleshooting Overview This guide covers basic troubleshooting It is helpful for solving many of the common problems that can arise with this system If majo...

Страница 26: ...erating the torch in a normal condition a small amount of gas air vents through the gap be tween the shield cup and torch handle Do not at tempt to over tighten the shield cup as irreparable damage to...

Страница 27: ...ting table Work Cable And Clamp Art A 04389 3 Current sensor or PWM PCB faulty a Return to an authorized service center for re pair F Air flows continuously and torch latch switch doesn t work properl...

Страница 28: ...SERVICE 5 4 Manual 0 4686 This Page Left Blank...

Страница 29: ...nds Then Stops Cutting Done Torch Switch On Air Flows at Torch Set Air Pressure Then Turn Air Set Switch Off Red Air Indicator Pilot Arc goes out Release Torch Switch Primary Input Power Switch Off or...

Страница 30: ...ch Torch Leads To Power Supply Adapter Disconnect power and air Lay unit on its side Remove two screws and the access panel Pilot Power Supply Adapter Negative Plasma Lead Art A 04674 Work Cable Pilot...

Страница 31: ...Manual 0 4686 6 3 APPENDIX This Page Left Blank...

Страница 32: ...erAssembly Replacement Kit 9 7034 3 1 Handle Screw Kit 5 each 6 32 x 1 2 cap screw and wrench 9 8062 4 1 Torch Head Assembly Replacement Kit includes items No 5 6 9 8219 5 1 Large O Ring 8 3487 6 1 Sm...

Страница 33: ...Manual 0 4686 6 5 APPENDIX 5 6 3 4 2 7 7 A 07060 1 8...

Страница 34: ...an Fan Pressure Sensor Solenoid V V Input Selection AC230 AC460 Input AC 230V 460V 1 3 Phase Filter Diode Fuse 3A IGBT IGBT Main Transformer Current Sensor Reactor Work Piece Pilot Torch Pilot Relay M...

Страница 35: ...Manual 0 4686 6 7 APPENDIX This Page Left Blank...

Страница 36: ......

Страница 37: ...trict Shanghai PR 200052 Telephone 86 21 69171135 Fax 86 21 69171139 Thermadyne Asia Sdn Bhd Lot 151 Jalan Industri 3 5A Rawang Integrated Industrial Park Jln Batu Arang 48000 Rawang Selangor Darul Eh...

Страница 38: ...Corporate Headquarters 16052 Swingley Ridge Road Suite 300 St Louis MO 63017 Telephone 636 728 3000 Email TDCSales Thermadyne com www thermadyne com...

Отзывы: