6.01 Setup and Operation
1.
Connect the unit to air supply and power.
2.
Connect the work lead clamp to cleaned area of work surface.
3.
Turn the switch located on the front panel, to the "On" position. The
A/C indicator on the front panel
should light.
4.
Set the air pressure. Press the Air Set Button
and set the regulator pressure to 65 psi (4.5 bar) (.45 MPa).
Air should be flowing continuously. Press the Air Set Button
again to stop the air flow.
NOTE:
If the Air Error Indicator light is on, and or there is an audible beeping tone, check for low or no air pressure.
5.
Squeeze the torch trigger (slight delay), pilot arc starts.
6.
Transfer arc to work surface before the arc goes out.
Содержание C-20A Cutskill
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 14: ...Installation 3 2 Manual 0 4697 This Page Left Blank ...
Страница 18: ...Operation 4 4 Manual 0 4697 This Page Left Blank ...
Страница 31: ...Manual 0 4697 7 3 Parts List Art A 07744 11 12 13 14 15 16 Art A 07745 17 18 19 20 21 22 23 24 ...
Страница 33: ...Manual 0 4697 7 5 Parts List 5 6 3 4 2 7 7 A 07060 1 8 ...
Страница 34: ...Parts List 7 6 Maual 0 4697 This Page Left Blank ...
Страница 40: ...APPENDIX A 6 Manual 0 4697 This Page Left Blank ...